---- 01 SMALL RIB LARGE RIB TRAFFIC RATED CULTEC INSPECTION PORT 24.2" [614mm]

Page 14

(SEE ZOOM DETAIL) CHAMBER CAN ACCOMMODATE 6" [150mm] AND 8" [200mm] SDR-35 OR SCH-40 PVC FIELD PLACED CLASS "C" CONCRETE COLLAR. CONCRETE COLLAR CAN RECEIVE ASPHALT GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% 36.0" [914mm]

Page 14

36.0" [914mm] OVERLAY IF DESIRED FINES, COMPACT IN 6" (150 mm) MAX. LIFTS TO 95% PROCTOR DENSITY NEW JERSEY AASHTO HS-20 RATED DUCTILE IRON FRAME AND COVER NON-WOVEN GEOTEXTILE AROUND

Page 14

NON-WOVEN GEOTEXTILE AROUND STONE. TOP AND SIDES MODEL 180SHD STARTER MANDATORY, BOTTOM PER ENGINEER'S DESIGN PREFERENCE SMALL RIB LARGE RIB CONCRETE COLLAR/ASPHALT OVERLAY NOT 262-270 MAIN ST SITE REDEVELOPMENT

Page 14

REQUIRED FOR NON-TRAFFIC APPLICATIONS SEPARATOR ROW/ADS ISOLATOR® ROW PLUS PAVEMENT TO BE COVERED WITH NON-WOVEN GEOTEXTILE 88.0" [2234mm] INLET STRUCTURE OR FINISHED GRADE DRAINAGE DETAILS

Page 14

DRAINAGE DETAILS 76.0" [1926mm] INSTALLED COMPACTED GRANULAR BACKFILL. THE BACKFILL 3 4" - 2" [20-50mm] CLEAN, CRUSHED, ANGULAR MATERIAL SHALL MEET THE REQUIREMENTS OF CLASS ELEVATED BYPASS PIPE STONE SURROUNDING CHAMBERS 38.0" [964mm] 38.0" [964mm]

Page 14

38.0" [964mm] 38.0" [964mm] I, II, OR III MATERIALS AS DEFINED BY ASTM D2321 JORGE MASTROPIETRO ARCHITECTS 7.0" [178mm] SMALL RIB LARGE RIB MODEL 180IHD INTERMEDIATE SITE CIVIL DESIGN 16.0" [406mm] CULTEC FC-24

Page 14

16.0" [406mm] CULTEC FC-24 CULTEC 12" PVC UNIVERSAL INLINE DRAIN BODY SMALL RIB LARGE RIB 12" PVC UNIVERSAL INLINE DRAIN BODY CAN BE TRIMMED TO 20.5" [521mm] ACCOMMODATE 6" [150mm], 8" [200mm] AND 10" [250mm] SDR-35 PVC PIPE ESSEX

Page 14

ESSEX 6" [150mm], 8" [200mm], OR 10" [250mm] SDR-35 RISER 24.0" [610mm] MIN. 28.0" [271mm] (LENGTH VARIES BASED ON SYSTEM DEPTH) SUMP RECOMMENDED 24.0" [610mm] SIDE PORTAL FOR OPTIONAL INTERNAL MANIFOLD 1 LAYER OF WOVEN GEOTEXTILE TO BE PLACED BENEATH MODEL 180EHD END (ACCOMMODATE CULTEC HVLV FC-24 FEED CONNECTOR

Page 14

(ACCOMMODATE CULTEC HVLV FC-24 FEED CONNECTOR HOLE TO BE CUT w/ HOLE SAW CENTERED ENTIRE SEPARATOR ROW/ADS ISOLATOR® ROW PLUS SMALL RIB LARGE RIB OR 12 INCH [300 mm] PIPE) ON CORRUGATION CREST. 6.25" [160mm], 36.0" [916mm] 8.50" [220mm], OR 10.75" [275mm] THE DESIGN ENGINEER IS RESPONSIBLE FOR ENSURING THAT THE REQUIRED 12.0" [305mm] BEARING CAPACITY OF SUB-GRADE SOILS HAS BEEN MET