Show all pagesF 48 HOURS BEFORE IMPOSING CONCENT-RATED OR OTHER LOADS FROM ABOVE. PROVIDE BOND BEAMS WITH TWO (2) #4 HORIZONTAL REINFORCEMENT CONTINUOUS IN ALL MASONRY WALLS AT EACH FRAMING LEVEL. PROVIDE A MINIMUM OF TWO (2) #4 BARS AT THE ENDS OF THE WALLS AND ON EACH SIDE OF EACH OPENING. ALL PIERS AND PARTITIONS SHALL BE BONDED OR ANCHORED TO ADJACENT MASONRY WALLS. PROVIDE TIES TO ADJACENT FLOOR AND ROOF CONSTRUCTION IN ACCORDANCE WITH DETAILS ON DRAWINGS. THE CONTRACTOR SHALL VERIFY ALL OPENINGS BELOW LINTELS INDICATED ARE ADEQUATE TO ACCEPT DO-ORFRAMES, LOUVERS, ETC. AS SHOWN ON THE ARCHITECTURAL AND MECHANICAL DRAWINGS. NOTIFY THE ARCHITECT AND STRUCTURAL ENGINEER OF ANY DISCREPANCIES PRIOR TO LINTEL INSTALLATION. 5. 6. 7. MINIMUM 28 - DAY COMPRESSIVE STRENGTH OF MASONRY, SHALL BE 1,500 PSI, UNLESS NOTED OTHERWISE FULL BED AND HEAD JOINTS SHALL BE PROVIDED. HORIZONTAL JOINT REINFORCING: ASTM A82; 9-GUAGE TRUSS-TYPE, GALVANIZED. 1. 2. 3. 4. MASONRY MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (TMS 402-2016) AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE SPECIFICATIONS FOR MASONRY STRUCTURES (TMS 602-2016) , EXCEPT WHERE OTHERWISE MODIFIED BY THESE GENERAL NOTES AND SPECIFICATIONS. MORTAR SHALL CONFORM TO ASTM C 270, TYPE M OR S. ALL PORTLAND CEMENT SHALL CONFORM TO ASTM C150, TYPE I. LIME SHALL CONFORM TO ASTM C207 AND MASONRY CEMENT SHALL CONFORM TO ASTM C91. GROUT SHALL CONFORM TO ASTM C 476 AND SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. SLUMP OF GROUT SHALL BE 8 TO 10 INCHES AND THE MAXIMUM AGGREGATE SIZE SHALL BE 3/8" (AGGREGATE GRADED TO PRODUCE FINE GROUT IN CONFORMANCE WITH ASTM C476 AND C404). CONCRETE BLOCK UNITS: SOLID AND HOLLOW LOAD BEARING UNITS PER ASTM C90, TYPE N-1, AS REQUIRED TO PROVIDE 28 DAY COMPRESSIVE STRENGTH AS NOTED BELOW. 20. 21. 22. 23. ALL MASONRY WORK TO BE EXECUTED IN COLD WEATHER SHALL BE IN CONFORMANCE WITH THE RECOM-MENDATIONS FOR COLD WEATHER CONSTRUCTION FOUND IN THE BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES ( TMS 402-2016 ) AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE SPECIFI-CATIONS FOR MASONRY STRUCTURES (TMS 602-2016) WITH THE FOLLOWING ADDITIONS: FOR ALL CONDITIONS WHEN TEMPERATURES FALL BELOW 40 DEGREES F, THE TEMPERATURE OF THE NEWLY LAID MASONRY OR NEWLY GROUTED MASONRY SHALL BE MAINTAINED ABOVE 32 DEGREES F FOR A MINIMUM OF 24 HOURS USING
FOR ALL CONDITIONS WHEN TEMPERATURES FALL BELOW 40 DEGREES F, THE TEMPERATURE OF THE NEWLY LAID MASONRY OR NEWLY GROUTED MASONRY SHALL BE MAINTAINED ABOVE 32 DEGREES F FOR A MINIMUM OF 24 HOURS USING THE METHODS DESCRIBED IN ACI 530.1. THE TESTING AND INSPECTION AGENCY SHALL MONITOR THE PROPORTIONING, MIXING, AND CONSISTENCY OF MORTAR AND GROUT ; THE PLACEMENT OF MORTAR , GROUT , AND MASONRY UNITS; AND THE PLACEMENT OF REINFORCING STEEL FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS. ALL WALL SECTIONS AND PIERS LESS THAN TWO SQUARE FEET IN CROSS-SECTIONAL AREA SHALL BE FULLY GROUTED. PROVIDE VERTICAL MASONRY CONTROL JOINTS AT MAXIMUM 25'-0"ON CENTER UNLESS DETAILED ON ARCHITECTURAL DRAWINGS, COORDINATE LOCATIONS WITH ARCHITECT. 24. NO OPENINGS SHALL BE PLACED ABOVE ANY LINTEL WITHIN A HEIGHT LESS THAN OR EQUAL TO THE WIDTH OF THE CLEAR OPENING BELOW THE LINTEL, UNLESS SPECIFICALLY SHOWN OR APPROVED BY THE STRUCTURAL ENGINEER.
File revisions (1)
- Sep 29, 2026
c74c4fdbca361,281,835 bytes