Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Sep 17, 2026

13 Porter Rd Application package rcd 6 2 2026

Preserved file SHA-256b4fb2ab8971ca51dca8b803c89b071e202c26a8d53966cbdd2771199000a4563

Indexed text · page 21

Show all pages
Page 21

ARCHITECT OF RECORD: FC3 ARCHITECTURE+DESIGN, LLC NJ CERT. OF AUTHORIZ. #AC-58100 22'-3" 12" CMU CORE-FILLED WALL SCHEDULE 2x4 STUD WALL W/ FOUNDATION WALL

Page 21

FOUNDATION WALL 1/2" GYP. BOTH SIDES 4'-0" 4'-0" 14'-3" W/ 1-#4 VERT. REBAR EXISTING WALL CONSTRUCTION. TYP. 2x4 WOOD CONSTRUCTION (V.I.F.) SPACKLE, SANDED, 4' O.C. 2' FROM EDGE PAINTED ON A 2' x 1' CONT. NEW INTERIOR 2x4 WOOD STUD PARTITION @ 16" O.C. W/ ONE LAYER 1/2" 36x18 SLIDER CONC. FOOTING GYP. BD. EACH SIDE. USE WATER RESISTANT GYP. BD. AT ALL WET AREAS

Page 21

GYP. BD. EACH SIDE. USE WATER RESISTANT GYP. BD. AT ALL WET AREAS (MIN. 3500 PSI) W/ USE CEMENTITIOUS BACKER BD. AT ALL SHOWERS / TUBS. 2-#4 REBAR HORIZ. GFI GFI REFER TO SECTION NO. 3 THIS PAGE NEW EXTERIOR WALL CONSTRUCTION: 8" CMU, CORE-FILLED BASEMENT WALL GFI

Page 21

GFI 2x10 FLOOR JOISTS 2x10 FLOOR JOISTS FRANK CUNHA III, AIA, NCARB @ 16" O.C. O.C.

Page 21

REGISTERED ARCHITECT CRAWL SPACE STORAGE NEW JERSEY #16411 @ 16" GFI 9'-0" CONC. NEW ADDITION 3

Page 21

NEW ADDITION 3 FC3 PROJECT NO. 26-NJ-XXX W8x12 W/ 2 A-100 HSS 4x4x1/4 HSS 4x4x1/4 COLUMN / POST NOTE: GENERAL FOUNDATION NOTES: 6 ON 1'x1'x1' FOOTING 32x80 1. ALL EXTERIOR DIMENSIONS MEASURED TO OUTSIDE FACE OF CMU WALL,

Page 21

1. ALL EXTERIOR DIMENSIONS MEASURED TO OUTSIDE FACE OF CMU WALL, 1. POSTS FOR "ONCENTER" STEEL BEAM TO BE SOLID THRU TO REST ON SOLID CONCRETE FOUNDATION, STL. COLUMN OR POST BELOW. ALL INTERIOR DIMENSIONS MEASURED TO INTERIOR FACE OF CMU, ALL EXIST. GARAGE INSTALLED IN ACCORDANCE W/ MANUFACTURERS SPECIFICATION. VERTICAL DIMENSIONS ARE TAKEN TO TOP OF GROUND.

Page 21

2. ALL DIMENSIONS TO BE VERIFIED IN FIELD. 2'-4" 10'-0" 2'-4" 3. FINAL STRUCTURAL DESIGN TO BE REVIEWED AND APPROVED BY LICENSED NEW EX. FAN 14'-7 1/2" STRUCTURAL ENGINEER. VENT THRU STORAGE

Page 21

STORAGE 4. ALL SIMPSON STRONG-TIES TO BE INSTALLED FLUSHED WITH FLOOR JOISTS LAUNDRY UNLESS OTHERWISE NOTED. BATH 5. FINAL UTILITY EQUIPMENT CONFIGURATION, PLUMBING, DUCT, ELECTRICAL,

Page 21

ETC., LOCATIONS TO BE DETERMINED BY CONTRACTOR AND THE OWNER. ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN SISTER EXIST. 6. LOCATE HVAC GRILLS AND DIFFUSERS ON CENTER OF WINDOW, DOOR, CONSTITUTE ORIGINAL AND

File revisions (1)