Show all pagesUTILITY EXHIBIT WORK LETTER TYPE: EX. KEY: LANDLORD TO FURNISH AND INSTALL CODE- 1 COMPLIANT 400-AMP, 120/208 VOLT, 3-PHASE, 4-WIRE METERED SERVICE CAPABLE OF SUPPLYING 120KVA BROUGHT TO 400-AMP RATED, 72-POLE MAIN DISTRIBUTION PANEL WITH A 400-AMP MAIN CIRCUIT BREAKER, AND ONE (1) 200-AMP, 72-POLE SUBPANEL, WITH CIRCUIT BREAKERS IN ACCORDANCE WITH THE TENANT’S PLANS. 2 NOT USED.
2 NOT USED. 3 NOT USED. LANDLORD SHALL FURNISH AND INSTALL A 4 FIRE SPRINKLER SYSTEM TO MEET APPLICABLE GOVERNMENTAL ORDINANCES FOR THE INTENDED USE OF TENANT AS ANTICIPATED BY THE LEASE. # $ " ! 5 LANDLORD SHALL FURNISH AND INSTALL A " ! SEPARATELY METERED NATURAL GAS SERVICE WITH A MINIMUM CAPACITY OF 1600MBH AND A DELIVERY PRESSURE OF 7” WATER COLUMN ROUTED TO THE ROOFTOP MECHANICAL
LUMN ROUTED TO THE ROOFTOP MECHANICAL UNITS, WITH A POINT OF CONNECTION WITHIN THE SPACE FOR INTERIOR TENANT FIXTURE HOOKUP. # &! )* # &" 6 LANDLORD SHALL FURNISH AND INSTALL A $ 10 ( SEPARATELY METERED AND INSULATED 2” DEDICATED DOMESTIC COPPER WATER SUPPLY LINE SUPPLYING A MINIMUM OF 55 PSI AFTER ALL 1 # &" METERING AND BACK FLOW DEVICES. LANDLORD # &"
METERING AND BACK FLOW DEVICES. LANDLORD # &" # & ! ! 8 4 SHALL FURNISH AND INSTALL A BOOSTER PUMP IF # &! # &" 7 THE PRESSURE IS UNABLE TO BE MET. LANDLORD " &# % 9 SHALL FURNISH AND INSTALL A SUB-METER # &! 5' AND CODE REQUIRED BACKFLOW PREVENTOR # &! # &" ( "# IN THE SPACE COORDINATED WITH CAVA’S CONSTRUCTION DOCUMENTS PRIOR TO THE POINT " " " " 6 OF CONNECTION. # &" # &"
6 OF CONNECTION. # &" # &" 7 LANDLORD SHALL FURNISH AND INSTALL A 4” !& ! ! &" $% ! SANITARY LINE WITH A MINIMUM INVERT OF 48” INVERT ELEVATION AT THE POINT OF CONNECTION. 8 LANDLORD SHALL INSTALL WITH GREASE INTERCEPTOR WITH A MINIMUM CAPACITY OF 2,500 GALLONS OR SUFFICIENT TO MEET LOCAL CODE FOR TENANT’S EXCLUSIVE USE WITH INVERT ELEVATION AS NECESSARY TO ACCOMMODATE GREASE INTERCEPTOR INSTALLATION REQUIREMENTS OF TENANT. THE GREASE INTERCEPTOR INSTALLATION SHALL BE A
E INTERCEPTOR INSTALLATION SHALL BE A MINIMUM OF 25-FEET AWAY FROM TENANT’S MAIN ENTRY DOORS AND PATIO SEATING. 9 CAVA SHALL PROVIDE AND INSTALL TWO (2) TWO-INCH (2”) EMPTY RIGID CONDUIT WITH PULL STRING (1) FROM THE PROPERTY’S TELEPHONE POINT OF DEMARCATION TO A LOCATION PER PLANS AND STUBBED WITHIN THE LEASED PREMISES AND (2) TO A LOCATION TO THE ROOF PER NOT TO SCALE LANDLORD’S PLANS. CAVA SHALL COORDIANTE ROUTING TO/FROM CAVA SPACE WITH THE LANDLORD. 10
LANDLORD. 10 LANDLORD SHALL FURNISH AND INSTALL A 4” GREASE LINE WITH A MINIMUM INVERT OF 48” INVERT ELEVATION AT THE POINT OF CONNECTION. CAVA WEST ORANGE, NJ PV PACKAGE 06.08.26