Supporting Documentation · Oct 7, 2026
Settlement of Litigation Agreement 2020
74e67d2bd4644901e7153c749b77074979a896d934f7de24a26b2586e2b342ecIndexed text · page 38
Show all pagesvy. The Environmental Compliance Officer shall review the application and respond within ten (10) days of receipt of all required information, vi. WEHI may appeal a negative decision to the Township Council for reconsideration. d. Utilize energy efficient double pane, low-e glazing on windows and patio doors throughout the development with the following minimum performance standards: i. Windows will have a minimum National Fenestration Rating Council (NFRC) - performance standard of: 1, U Factor </=,30 2. SHGC ->/=.40 a. Window selection may be modified based on the orientation of the residential units, Windows facing East/South and West must meet both criteria. Windows facing North may waive the SHGC standard but must meet the U factor standard, ii, Patio or glass doors of any type leading from residential units to balconies or patios will have minimum National Fenestration Rating Council (NFRC) performance standard of: 1. U Factor <=30 2. SHGC ->/=.40 a. Door selection may be modified based on the orientation of the residential units, Windows facing East/South and West must meet both criteria. Windows facing North may waive the SHGC standard but must meet the U factor standard. ©. Utilize Energy Star or DLC approved LED lighting throughout interior and exterior. For common area exterior site lighting, provide Dark Sky Qualified lighting and incorporate one or more of the following: i. Motion sensor controls ii. Integrative photovoltaic cells, iii. Photosensors iv. Astronomic time-clock operation f. Renewable energy: Design structures to allow for future incorporation of solar panels, . Each lavatory faucet will have a maximum flow rate of 1.5 gallons per minute. . Each toilet shall utilize no more than 1.28 gallons per flush. Each showerhead will have a maximum flow rate of 2.0 gallons per minute. Covered Parking Areas: Reduce tenant exposure to indoor pollutants from covered parking through the use of tightly sealed building envelope and natural or mechanical ventilation of enclosed parking areas per the building code standards. _ i. Ata minimum, all conditioned spaces above the garage shall have all penetrations and all connecting floor and ceiling joist bays sealed. ii, Electric Vehicle Charging Stations: Install electric vehicle charging stations at each building (within underground parking area) and make provisions for additional future charging
st bays sealed. ii, Electric Vehicle Charging Stations: Install electric vehicle charging stations at each building (within underground parking area) and make provisions for additional future charging stations through installation of conduit. Some stg
File revisions (1)
- Sep 29, 2026
74e67d2bd4641,079,865 bytes