Supporting Documentation · Dec 2, 2026
Crestmont_July_1_2026_Condensed_with_Keyword_Index
6b01a07575178f40ccc1c7fd2bb7800eee739e10fe0f22bab1042ebe5cb03c5aIndexed text · page 36
Show all pages1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cote - Direct 135 A Correct. Q We’re reducing -- A Reducing. Yes. Q We’re reducing the existing deficit. A That is correct. My -- yeah. So you can qualify it as that these increase in spaces reduces the current relief that you granted this site previously so that we’re going from the 252 spaces previously approved in the -- in a prior site plan variance against the 700 that the ordinance would call for to 292 spaces, and therefore reducing the relief previously granted on the site. So, these layouts of the roadways with the standard parking spaces, the 24-foot drive aisle, the configuration I -- I’ve referred to in terms of the connection, what we’ve done is we’ve taken for emergency vehicles, I’m going to switch now to our traffic circulation, or excuse me, our fire truck circulation plan, and routed those through these new features added to the site to show that they can maneuver and emergency vehicles can access these locations and progress through them. So this is the westerly side, showing through the new parking facility based upon the West Orange ladder truck that’s been given to us dimensionally for this particular support of this area. And then on the1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cote - Direct 136 easterly half of the site, the same scenario there. We show now the fire truck maneuvering both through the existing parking lot also making its way through the proposed reconfiguration of the lower lot as well as using the egress scenario to access -- to exit out onto Eagle Rock Avenue, both in an easterly and a westerly fashion. So moving on to the way the site is graded for the purpose of the -- the layout, I refer to the upper level and lower level parking lot because of the changing grades as we make our way along, and the changing grades on this site are significant. There are a number of locations where we’re overcoming the existing conditions, the grades, and in -- part of the driving factor between where we’ve put walls on this site and the reason for the walls are to help minimize the number of trees removed. And I’m going to get to the testimony about the number of trees to be removed and the number of trees that are going to be replaced as a function of the development. But basically, just to give a quick perspective on it, if Eagle Rock Avenue
ut the number of trees to be removed and the number of trees that are going to be replaced as a function of the development. But basically, just to give a quick perspective on it, if Eagle Rock Avenue is sitting at let’s say an area where I’m pointing to at elevation 547, the upper parking lot area here is at 566. And we’re making the stormwater and the -- and the grading associated with this to control all the runoff from the site as a1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cote - Direct 137 combination of these small-scale basins I referred to earlier, one in the northwest corner and one at the east end of the site, northeast end of the site, and we’re also providing a swale at the top of the wall to direct water rather than sheet-flowing out onto Eagle Rock Avenue, to progress into the system and make its way into a controlled drainage conveyance system, the -- the piping network that conveys this, flows from the site. One of the things we did towards the discussion about the safety associated with Eagle Rock Avenue is we also evaluated the stormwater on Eagle Rock Avenue and found the existing system to be deficient and we’re upgrading that system along Eagle Rock Avenue to accommodate the flows that -- and the deficient scenario where now can get a suitable system installed associated with these improvements. So that’ll improve the drainage aspects of Eagle Rock Ave, controlling the sheet flow that goes uncontrolled today as well as doing the volume reduction -- the -- excuse me, the -- the flow reductions that we need to do to be compliant with the stormwater regulations. Looking at the second sheet, on the east side of the site, and again, the upper parking lot configuration, just to kind of give people a sense of1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cote - Direct 138 where we are elevation-wise, this upper lot is, say, 560, elevation 560, 558 and along that range at the -- the top end of it. Then we make our way to 564, making our way up to the top of what is the new exit driveway. And that exit driveway at 564 runs down the driveway until we get down to Eagle Rock Avenue, which is roughly around elevation 538. So from 564 to 538, one of the elements needed for that is we needed to make the driveway at eight and a half percent to support that move -- that transition and grade down. And in addition
ation 538. So from 564 to 538, one of the elements needed for that is we needed to make the driveway at eight and a half percent to support that move -- that transition and grade down. And in addition to that transition of the eight and a half percent to get down to Eagle Rock Ave, we also had to utilize walls to be able to support those changes in grades to maintain the upper level parking lot, the grades adjacent to going -- making your way down the hill to Eagle Rock Avenue, and also to allow for a stormwater basin to be built on the site. So one of the variance requests in this application is for the height of the walls. And the 21.5-foot height of the wall occurs where we have this lower level basin, you know, basically at a level that is compatible with getting it out to the street for street grade and dealing with the Eagle Rock discharges and supporting the upper level parking, and that transition occurs at this north end.
File revisions (1)
- Nov 20, 2026
6b01a0757517410,140 bytes