Show all pages1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cote - Direct 147 all -- the property that’s within the West Orange limits of the property. So, looking back, then, at the plant set, the other elements we’re adding to this are lighting. The lighting plans, this is LL-101, which is the partial lighting plan associated with the westerly portion of the site. We’re providing fixtures in the new parking lot area and we’re also providing fixtures along Eagle Rock Avenue. There were comments in the letters asking about the two different mounting heights. On-site, we’re using the 18-foot, or ordinance mounting height. Off-site, we’re working with the existing layout of the holes that are out there now, and they operate at a 27- foot height. And the -- those are the standard -- they’re referred to as cobra head-type lights. That’ll be lighting the county. And that’s -- that will be within the county’s jurisdiction, so we’re not proposing 27-foot high on the property. So we don’t see that as a variance, because it’s going to be under the county’s jurisdiction. But we want to make note of why there’s a differential between the two different heights. Another item noted, and I’m going to go to the easterly drawing now. This is LL-102. In a similar fashion, we’re providing lighting in the upper parking lot area down the access drive. When we get to the end1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cote - Direct 148 of the access drive, there’s a note about a potential variance about a foot-candle intensity of 3.5 at the property line where the driveway comes out. We’re lighting the driveway for purposes of the county’s review, so I don’t know, if it’s considered a variance, if it would be under county’s jurisdiction for the purpose of the lighting. But if it is, you know, then we would ask for that variance to be granted associated with it being to comply with the off-site roadway design requirements for the lighting along Eagle Rock Avenue. Otherwise, the light fixtures are -- I’m going to refer down to the detail sheet. This is sheet LL-501. They’ll -- they’re the -- what they refer to as the pedestrian post-mount op -- sorry, post-top pedestrian lights. Are basically fixture heads mounted at the 18- foot mounting height. That’s per the ordinance. And then out on the street, on Eagle Rock Avenue, they’ll have the -- excuse me, the
p pedestrian lights. Are basically fixture heads mounted at the 18- foot mounting height. That’s per the ordinance. And then out on the street, on Eagle Rock Avenue, they’ll have the -- excuse me, the cobra head light, which -- people may be familiar -- familiar with. They’re similar to what’s out there now along Eagle Rock Avenue. So, you know, looking at it from the -- the big picture, go back -- excuse me, I apologize, to the overall site and the variances that we’re asking for, I’m just going to renumerate (sic) them, if you don’t1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cote - Direct 149 mind, just to put it on record. I’m going to go back to the initial plan for the site plan. So we have the variance from section 25-12.1.b, the minimum distance from parking area to fencing, screening, or structure. Again, that occurs in proximity to the modular structure that was recently constructed and we’re using that as a protective measure for the allowing still the pedestrian access adjacent to that modular building. The second variance, or next variance was the minimum number of parking spaces. We -- where 700 is required. We’re -- we’re reducing the current variance from 252 spaces to 292 spaces, and that’s associated with the testimony provided by -- by the -- for the operations to say that the additional parking is associated with changes the way the facility’s been utilized in recent times. The next variance is the -- section 25-28.8.f.11, the maximum retaining wall height of feet. We’re proposing 21.2 -- 21.5 feet, excuse me. And again, that’s specifically related to the area where we are combining the upper lot improvements and in contrast to the lower level retention basin that we need, or retention -- small-scale bio-retention basin needed to hit the water quality and water quantity requirements for stormwater management. So that area is basically1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cote - Direct 150 where that occurs. Then, looking at the variance request for the -- related to the steep slopes, so a lot of what I spoke about earlier is reflected in the steep slopes exhibits that are provided in the plan set. This is actually the partial steep slope analysis with site plan overlay drawing, EX-04. What EX-04 identifies is the various areas on the site, and the -- and the extent of the slopes
n the plan set. This is actually the partial steep slope analysis with site plan overlay drawing, EX-04. What EX-04 identifies is the various areas on the site, and the -- and the extent of the slopes within those areas. So the -- Q John? John, hold on one second. We didn’t submit that colorized, did we? A Yes, we did. Q We did -- our plan set has it colorized? A Yeah. Yeah. Q Okay. A That’s -- that’s correct. Yes. So -- so, looking at that from an overall -- you know, the big picture is that this end of the site, in order to make your way from where we’re starting with at the upper level parking lot and lower level parking lot out to Eagle Rock Avenue, there’s a transition in topography to get down to Eagle Rock Avenue. Those -- those elevations I was talking about before in that 20- to 30-foot range of changing grade over portions of the site. So, in order to minimize some of the disturbances,
File revisions (1)
- Nov 20, 2026
6b01a0757517410,140 bytes