Show all pagesLLC June 13, 2018 Leonard R. Lepore, Municipal Engineer Director of Public Works Township of West Orange 25 Lakeside Drive West Orange, NJ 07052 ASBESTOS MONITORING SERVICES NJASCM / AST PROPOSAL FOR West Orange Library Miscellaneous Building Improvements West Orange, NJ Dear Mr. Lepore: The following is our sub-consultant Environmental Health Investigations, inc. (EHI) proposal to provide Asbestos Safety Control Monitor (ASCM) and Asbestos Safety Technician (AST) services with respect to asbestos removal operations anticipated for the Library. This proposal is based on the following asbestos containing materials (ACMs) being removed and the building being completely unoccupied during the removal process. ACM determination per report provided by the Township dated May 29, 2018. © VAT Floor Tiles ¢ — Roof Materials © Ceiling Tiles The asbestos abatement/removal of ACM found in the Library is governed by the New Jersey Asbestos Hazard Abatement Subcode of the Uniform Construction Code commonly referred to as Sub-Chapter 8. This regulation requires that an ASCM firm be retained to oversee the asbestos removal process. This proposal is however based on the assumption that removal of all asbestos floor tile and mastic will be performed via non- friable methods thus exempting the removal from Sub-Chapter 8. This exemption does not require that an ASCM firm be retained to oversee the asbestos removal process, however removal of flooring materials via a non-friable method will require final clearance air monitoring, EHI will provide the following: TASK 1: Project Planning, Scope Determination, Specification Development, Pre-Con Meetings & De-scope 1. An EPA Accredited Asbestos Project Designer will generate two separate written scope documents for each Firehouse. These documents will be submitted to the local construction official when securing a permit to conduct the work. 2. EH will generate separate plans for the abatement at each location. EHI will issue approval letters for submission to the local construction official when securing a permit to conduct the work. Architecture & Planning NJ Certificate of Authorization AC 830 611 Main Street, Second Floor, Boonton, NJ 07005 Telephone 973 538 3815 Facsimile 973 538 4095 www.herbstmusciano.com a.
File revisions (1)
- Sep 29, 2026
200337f7a4da2,407,770 bytes