Show all pages4. Using a number three (3) Phillips head screwdriver loosen the screw and remove uni-tension wire clamp from the face ring. 5. Remove the face ring and wire clamp from the light housing and set aside for installation later. Note: A 120 VAC to 12 VAC external transformer is required for the 12 VAC model IntelliBrite LED Spa light. See page 9 for more information. Loosen the Phillips screw to remove wire clamp Note: The IntelliBrite Spa Light fixture is a sealed light assembly which is replaceable. The lens, gasket and face ring can be removed from the sealed light assembly for replacement. See page 15 for replacement kit part numbers. IntelliBrite spa light fixture with lens, gasket and face ring attached 6. With the light assembly resting on its base, carefully pry off the gasket to release the lens. Discard the gasket. ANEW LENS GASKET MUST BE USED EACH TIME THE SPA LED LIGHT IS REASSEMBLED 7. Disconnect the IntelliBrite Spa LED light assembly cable from the junction box and discard the light assembly. IntelliBrite® Pool and Spa White LED Light Installation and User’s Guide