10. With the hook ends of the circular uni-tension wire clamp pointing down, spread the clamp and place it in the “U" recesses of the locking levers. Be sure the hook ends of the wire clamp are located between the pair of locking levers as. shown below and that the clamp is properly engaged with all of the lock levers. 11. Place a cloth on the ground to protect the lens. Turn the light over so the lens is resting on the cloth. Tighten the bolt and nut until the distance between the ends of the clamp equals ‘4-in or less. 12, PROCEED TO “Replacing the IntelliBrite White LED Light Assembly (in an existing pool or spa)” on page 16 for spa light assembly installation instructions. Orientation of bolt and wire clamp Pilot Screw Tighten nut and bolt about 90° from the Pilot Screw between the lock levers, IntelliBrite ‘Spa light assembly \ we Hook ends. : wire clamp . oon and Lock lever bolt (x4), Gasket Lg Face ring Pilot screw IntelliBrite® Pool and Spa White LED Light Installation and User's Guide