Show all pages12/9/24, 2:36 PM Print : Quotebullder : ServiceTrade From Encore Fire Protection 25 Eastmans Road <! e a CO re Parsippany NJ 07054 (973) 560-1600 — FIRE PROTECTION http://www, enicorefireprotection.com/ If you have any questions or concerns please reach us at servicelocation15@encorefirepratection.com Quote No. | 2112221 Quote For | TOWNSHIP OF WEST ORANGE TOWNSHIP OF WEST ORANGE - FIREHOUSE #5 25 MT. PLEASANT PLACE i WEST ORANGE NJ 07052 (973) 725-8774 Type Repair Prepared By Phillip Goviello I Created On 11/27/2024 | Valid Until 01/17/2025 Description of Work 41. PERFORM (1) REQUIRED § YEAR WET INTERNAL OBSTRUCTION INVESTIGATION LOCATED IN BASEMENT. 2, PERFORM (1) REQUIRED 5 YEAR HYDROSTATIC TEST OF THE FIRE DEPARTMENT GONNECTION, (FREE STANDING IN FRONT OF BUILDING). 3. PERFORM (71) REQUIRED 5 YEAR INTERNAL OBSTRUCTION INVESTIGATION ON 4" WILKINS - 950 - DCV BACKFLOW PREVENTER. «CONTENTS OF ANTI-FREEZE LOOP IS UNKNOWN, EXISTING ANTIFREEZE LOOP WILL NEED TO BE DRAINED AND. REPLACED WITH A UL LISTED NONCOMBUSTIBLE SOLUTION. (2ND FLOOR STAIRWELL) 4, DRAIN AND REPLACE EXISTING ANTI-FREEZE WITH UL LISTED NON-COMBUSTIBLE SOLUTION. ANT-FREEZE SYSTEM SHOULD TAKE APPROXIMENTLY 25 GALLONS. IF ADDITIONAL ANTI-FREEZE IS NEEDED, IT WILL BE BILLED AT RATE BELOW. THE COST PER GALLON OF UL LISTED ANTI-FREEZE IS $90.00 PER GALLON. THIS QUOTE INCLUDES (25) GALLONS OF SOLUTION. IF ADDITIONAL SOLUTION IS NEEDED TO FILL SYSTEM, THE CUSTOMER SHALL BE BILLED ACCORDINGLY. 5, FILL OUT AND INSTALL (1) ANTI-FREEZE SIGN AT ANTI-FREEZE LOOP. * OBSTRUCTIONS, SUCH AS CORROSION OR SEDIMENT CAN ACGRUE OVER TIME, CAUSING WATER TO SLOW OR BE TRAPPED WHEN DISCHARGING IN AN EMERGENCY, CODE REFERENCE: NFPA 25 CHAPTER 14.2.1.1 INDICATES THAT AN ASSESSMENT OF THE INTERNAL PIPING SHALL BE CONDUCTED AT A MINIMUM OF EVERY 5 YEARS. RECOMMENDATION: PERFORM INTERNAL INVESTIGATION OF SYSTEM VALVE, RISER, CROSS MAIN AND BRANCH LINE. * THIS QUOTE DOES NOT INCLUDE NJ SALES TAX, (IF APPLICABLE), * ENCORE FIRE IS NOT RESPONSIBLE FOR THE INTEGRITY OF THE EXISTING FIRE SPRINKLER SYSTEN, AND ALL OF ITS COMPONENTS. “IF ADDITIONAL WORK IS DEEMED NECESSARY BY ENCORE FIRE AND/OR THE AUTHORITY HAVING JURISDICTION TO ENSURE SYSTEM OPERATION, AND/OR ENSURE CODE COMPLIANCE, ADDITIONAL. CHARGES SHALL APPLY. * NORMAL WORKING HOURS ARE MONDAY THROUGH FRIDAY, 8:00 AM TO 4:30 PM. ANY WORK NEEDING TO
VING JURISDICTION TO ENSURE SYSTEM OPERATION, AND/OR ENSURE CODE COMPLIANCE, ADDITIONAL. CHARGES SHALL APPLY. * NORMAL WORKING HOURS ARE MONDAY THROUGH FRIDAY, 8:00 AM TO 4:30 PM. ANY WORK NEEDING TO BE PERFORMED OTHER THAN ABOVE MENTIONED TIMES, OVERTIME RATES WILL APPLY. * THIS QUOTE DOES NOT INCLUDE ANY WORK NOT MENTIONED ABOVE, + ENCORE FIRE PROTECTION ACKNOWLEDGES THAT THIS CONTRACT IS SUBJECT TO THE PROVISIONS, DUTIES, OBLIGATIONS, REMEDIES AND PENALTIES OF THE NEW JERSEY PREVAILING WAGE ACT. THEREFORE, THIS CONTRACT https://app.servicetrade.com/quotebullder/printfid/1805702204931777 116
File revisions (1)
- Sep 29, 2026
cd27761958b23,795,831 bytes