Show all pagesC. Procedure. The crumb rubber for asphalt rubber binder is required to conform to the gradations specified below when tested in accordance with ASTM Designation C 136 except as follows: 1, 2. Obtain 100 + 5 grams from the crumb rubber sample and dry to a constant weight at a temperature of not less than 135 °F nor more than 145 °F and record the dry sample weight. Place the crumb rubber sample and 5.0 grams of talc in a one pint jar, then shake it by hand for a minimum of one minute to mix the crumb rubber and the talc. Continue shaking or open the jar and stir until the particle agglomerates and clumps are broken and the talc is uniformly mixed. Place one rubber ball on each sieve. After sieving the combined material for 10 + 1 minutes, disassemble the sieves. Brush remaining material adhering to the bottom of a sieve into the next finer sieve. Weigh and record the weight of the material retained on the No. 8 sieve and leave this material (do not discard) on the scale or balance. Ensure that observed fabric balls remain on the scale or balance and are placed together on the side of the scale or balance to prevent the fabric balls from being covered or disturbed when placing the material from finer sieves on to the scale or balance. Add the material retained on the next finer sieve (No. 16 sieve) to the scale or balance. Weigh and record that weight as the accumulative weight retained on that sieve (No. 16 sieve). Continue weighing and recording the accumulated weights retained on the remaining sieves until the accumulated weight retained in the pan has been determined. Before discarding the crumb rubber sample, separately weigh and record the total weight of the fabric balls in the sample. Determine the weight of material passing the No. 200 sieve (or weight retained in the pan) by subtracting the accumulated weight retained on the No. 200 sieve from the accumulated retained weight in the pan. If the material passing the No. 200 sieve (or weight retained in the pan) has a weight of 5 grams or less, cross out the recorded number for the accumulated weight retained in the pan and copy the number recorded for the accumulated weight retained on the No. 200 sieve and record that number (next to the crossed out number) as the accumulated weight retained in the pan. If the material passing the No. 200 sieve (or weight retained in the pan) has a weight greater
ve and record that number (next to the crossed out number) as the accumulated weight retained in the pan. If the material passing the No. 200 sieve (or weight retained in the pan) has a weight greater than 5 grams, cross out the recorded number for the accumulated weight retained in the pan, subtract 5 grams from that number and record the difference next to the crossed out number. The adjustment to the accumulated with retained in the pan is made to account for the 5 grams of the tale added to the sample. For calculation purposes, the adjusted accumulated weight is the same as the adjusted accumulated weight retained in the pan. Determine the percent passing based on the adjusted total sample weight and recorded to the nearest 0.1 percent. D. Report. Report all test results on ME provided forms. NJDOT B-12 — DETERMINING ROTATIONAL VISCOSITY OF ASPHALT RUBBER BINDER A. Scope. This method presents procedures for sampling and testing of asphalt-rubber binder in the field using a hand held portable rotational analog or digital viscometer. B. Apparatus. Use the following apparatus: fi Viscometer. A hand held high range rotational viscometer. Analog models with indicator needles and scaled dial displays or digital read out viscometers may be used. Analog models that have been found acceptable include Rion Model VT-04E and Haake Model, VT-02. Digital models that have been found acceptable include Haake VT 2 Plus. Rotor. A cylinder with a diameter of 24 + 1.1 millimeters, height of 53 + 0.1 millimeters, and a vent hole attached to a spindle or shaft with length of 87 + 2 millimeters that is compatible with the selected viscometer. Acceptable rotors include Rion No. 1, Haake No 1, or an equivalent. Thermometer. Digital with metal jacket probe accurate to 1 °F. Sample Containers. Clean 1 gallon metal cans with lids and wire bale. 63
File revisions (1)
- Sep 29, 2026
c399b70b6d21122,934,801 bytes