E E E GV N 68°41'33" W FRANKLIN AVENUE OH OH OH OH OH OH OH OH OH OH OH OH OH OH OH OH OH OH OH OH OH OH OH OH (60 FT WIDE) 100.00' 125.00' S 21°18'27" W N 21°18'27" E 100.00' S 68°41'33" E 100.00' 100.00' OH OH OH OH OH OH OH OH OH OH OH OH OH OH OH OH OH 5' 5.2' 10' 20' 20' 6.7' 5.1' 5.1' 1.3'8.5' 8.7' X X X X X X X X X X X X X X X X X X X X X X X X X X X X 24'18' 11' 9' 8.9' 24.7' 1.3' 6.2' 6.4' 6.4' 2.6' 3.2' 28.4' 5' 6.4' 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.0 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.0 0.00.00.00.00.00.00.00.10.10.10.10.10.00.00.00.00.0 0.00.00.00.00.00.10.10.20.20.20.10.10.10.10.0 0.00.0 0.00.00.00.00.10.30.50.50.50.30.40.5 0.50.20.10.00.0 0.00.00.00.00.00.00.00.00.20.71.23.43.2 0.60.00.00.0 0.00.00.00.10.00.00.00.01.31.42.5 6.10.00.00.00.0 0.00.00.00.31.43.23.52.3 1.52.0 6.20.00.00.0 0.00.00.10.72.24.54.02.51.62.5 6.40.10.00.0 0.00.10.10.72.54.64.12.5 1.72.75.30.10.00.0 0.00.10.10.31.93.7 4.02.61.82.45.70.10.10.0 0.00.10.00.1 1.73.13.73.1 2.43.04.60.10.10.0 0.00.0 0.00.01.4 2.83.63.8 3.63.53.40.10.00.0 0.00.0 0.00.01.02.3 3.64.54.54.33.30.10.00.0 0.00.00.00.00.72.64.24.74.12.50.10.00.0 0.00.00.00.00.30.71.11.5 1.91.51.1 0.00.00.10.00.00.0 0.00.00.00.00.00.00.10.00.00.00.00.00.0 A (18') A (18')A (18') B (10') B (10') C (8') CHESTNUT STREET (50 FT WIDE) GENERAL LIGHTING NOTES 1. THE LIGHTING LEVELS DEPICTED WITHIN THE PLAN SET ARE CALCULATED UTILIZING DATA OBTAINED FROM THE LISTED MANUFACTURER. ACTUAL ILLUMINATION LEVELS AND PERFORMANCE OF ANY PROPOSED LIGHTING FIXTURE MAY VARY DUE TO UNCONTROLLABLE VARIABLES SUCH ARE WEATHER, VOLTAGE SUPPLY, LAMP TOLERANCE, EQUIPMENT SERVICE LIFE AND OTHER VARIABLE FIELD CONDITIONS. 2. WHERE APPLICABLE, THE EXISTING LIGHT LEVELS DEPICTED WITHIN THE PLAN SET SHALL BE CONSIDERED APPROXIMATE. THE EXISTING LIGHT LEVELS ARE BASED ON FIELD OBSERVATIONS AND THE MANUFACTURER'S DATA OF THE ASSUMED OR MOST SIMILAR LIGHTING FIXTURE MODEL. 3. UNLESS NOTED ELSEWHERE WITHIN THIS PLAN SET, THE LIGHT LOSS FACTORS USED IN THE LIGHTING ANALYSIS ARE AS FOLLOWS: · LIGHT EMITTING DIODES (LED): 0.90 · HIGH PRESSURE SODIUM: 0.72 · METAL HALIDE: 0.72 4. THE CONTRACTOR SHALL NOTIFY STONEFIELD ENGINEERING & DESIGN, LLC. IN WRITING, PRIOR TO THE START OF CONSTRUCTION, OF ANY PROPOSED LIGHTING LOCATIONS THAT CONFLICT WITH EXISTING/ PROPOSED DRAINAGE, UTILITY, OR OTHER IMPROVEMENTS. 5. THE CONTRACTOR IS

Page 6

G & DESIGN, LLC. IN WRITING, PRIOR TO THE START OF CONSTRUCTION, OF ANY PROPOSED LIGHTING LOCATIONS THAT CONFLICT WITH EXISTING/ PROPOSED DRAINAGE, UTILITY, OR OTHER IMPROVEMENTS. 5. THE CONTRACTOR IS RESPONSIBLE TO PREPARE A WIRING PLAN AND PROVIDE ELECTRIC SERVICE TO ALL PROPOSED LIGHTING FIXTURES. THE CONTRACTOR IS REQUIRED TO PREPARE AN AS-BUILT PLAN OF WIRING AND PROVIDE COPIES TO THE OWNER AND STONEFIELD ENGINEERING & DESIGN, LLC. ATM LIGHTING NOTES: 1. THE CONTRACTOR SHALL REPLACE LAMP COVERS, RE-LAMP AND RE-BALLAST EXISTING LIGHT FIXTURES AS INDICATED WITHIN THE PLAN SET. THE EXISTING FIXTURE HEIGHT SHALL BE MAINTAINED UNLESS INDICATED OTHERWISE. THE LIGHTING DESIGN IS SUBJECT TO CHANGE IF THE EXISTING LIGHT FIXTURES ARE NOT GREATER THAN OR EQUAL TO THE FOLLOWING WATTAGE: FIXTURE 'X' = MINIMUM X WATTS 2. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY STONEFIELD ENGINEERING & DESIGN, LLC. IN WRITING IF THE EXISTING LIGHT FIXTURES ARE NOT THE MINIMUM WATTAGE SPECIFIED WITHIN THE PLAN SET. 3. THE CONTRACTOR IS RESPONSIBLE TO CONFIRM THAT ANY EXISTING LIGHT POLES IDENTIFIED FOR REUSE WITH A PROPOSED LIGHT FIXTURE(S) SHALL BE IN ACCEPTABLE WORKING CONDITION AND HAVE THE CAPACITY TO SUPPORT THE PROPOSED LIGHT FIXTURE(S). ANY MOUNTING EQUIPMENT REQUIRED TO ATTACH THE PROPOSED LIGHTING FIXTURE TO THE EXISTING LIGHT POLE SHALL BE PROVIDED BY THE CONTRACTOR. 4. THE CONTRACTOR SHALL CONFIRM THAT THE LOCATION OF ANY PROPOSED BUILDING MOUNTED LIGHTING FIXTURE WILL NOT CONFLICT WITH ANY EXISTING OR PROPOSED STRUCTURAL ELEMENT (E.G. CANOPY SUPPORT BEAMS). THE CONTRACTOR SHALL NOTIFY STONEFIELD ENGINEERING & DESIGN, LLC. IN WRITING OF ANY FIXTURE CONFLICT PRIOR TO THE START OF CONSTRUCTION. 5. ALL EXISTING TREE LIMBS WITHIN THE 60 FOOT ATM RADIUS SHOWN IN THE PLAN SET SHALL BE TRIMMED TO A MINIMUM OF 6 FEET ABOVE GRADE. ALL SHRUBS WITHIN THE 60 FOOT ATM RADIUS SHALL BE TRIMMED TO A MINIMUM OF 36 INCHES ABOVE GRADE. ALL BRUSH SHALL BE REMOVED. THE CONTRACTOR SHALL CONSIDER ALL FUTURE GROWTH AND FULL BLOOM WHEN TRIMMING LANDSCAPING. EXISTING TREE LIMBS ADJACENT TO LIGHTING FIXTURES SHALL BE TRIMMED AS REQUIRED TO PREVENT LIGHT INTERFERENCE. 6. PRIOR TO BID, CONTRACTOR SHALL VERIFY EXISTING EXTERIOR LIGHTING CONDITIONS AFTER DUSK AND NOTIFY THE DEVELOPER/OWNER AND STONEFIELD ENGINEERING & DESIGN, LLC. OF DAMAGED OR INOPERABLE LIGHTS. THE CONTRACTOR

Page 6

O BID, CONTRACTOR SHALL VERIFY EXISTING EXTERIOR LIGHTING CONDITIONS AFTER DUSK AND NOTIFY THE DEVELOPER/OWNER AND STONEFIELD ENGINEERING & DESIGN, LLC. OF DAMAGED OR INOPERABLE LIGHTS. THE CONTRACTOR SHALL REPAIR ALL INOPERABLE LIGHTS UNLESS OTHERWISE NOTED WITHIN THIS PLAN SET. 7. THE ILLUMINATION LEVELS DEPICTED WITHIN THE PLAN SET ARE BASED ON REGULATORY STATE STANDARDS FOR SAFETY LIGHTING AND ON CLIENT STANDARDS. 8. ALL LIGHTING FIXTURES, UNLESS OTHERWISE NOTED WITHIN THIS PLAN SET, HAVE THE PHOTOCELL OPTION ENABLED. 9. EXISTING LIGHTING FIXTURES CONTROLLED BY OUTSIDE ENTITIES (E.G. LANDLORD) HAVE BEEN EXCLUDED FROM THE LIGHTING ANALYSIS REFLECTED WITHIN THE PLAN SET. THE PROPOSED LIGHT LEVELS HAVE BEEN DESIGNED TO COMPLY WITH ALL APPLICABLE ATM AND SAFETY LIGHTING REQUIREMENTS INDEPENDENT OF ANY UNCONTROLLED LIGHT FIXTURES. \\US.STONEFIELDENG.COM\SHARES\RUTHERFORD\RUT\2021\RUT-210050 MANUEL VEGA - 66 FRANKLIN AVENUE, WEST ORANGE, NJ\CADD\PLOT\RDP-06-LGHT.DWG ISSUE DATE DESCRIPTION NOT APPROVED FOR CONSTRUCTION PRELIMINARY & FINAL MAJOR SITE PLAN BY TITLE: SCALE: PROJECT ID: DRAWING: PROPOSED BUILDING ADDITION & SITE IMPROVEMENTS ESSEX COUNTY, NEW JERSEY RUT-210050 01 09/24/2021 FOR MUNICIPAL SUBMISSIONMAGR TOWNSHIP OF WEST ORANGE 66 FRANKLIN AVENUE BLOCK 134.02, LOTS 75.03, 79 & 81 Rutherford, NJ · New York, NY · Boston, MA Princeton, NJ · Tampa, FL · Detroit, MI www.stonefieldeng.com Headquarters: 92 Park Avenue, Rutherford, NJ 07070 Phone 201.340.4468 · Fax 201.340.4472 JOSHUA H. KLINE, P.E. NEW JERSEY LICENSE No. 54347 LICENSED PROFESSIONAL ENGINEER M. VEGA INVESTMENTS LLC 02 01/07/2022 FOR MUNICIPAL RESUBMISSIONNRK 03 08/04/2022 FOR MUNICIPAL RESUBMISSIONMAGR 04 09/01/2022 FOR MUNICIPAL RESUBMISSIONMAGR GRAPHIC SCALE IN FEET 0' 20'10'10' 1" = 10' LIGHTING PLAN C-6 1" = 10' A (XX') X.X PROPOSED CALCULATION AREA SYMBOL DESCRIPTION PROPOSED 0.5 FC ISOMETRIC LINE (FIXTURE) PROPOSED LIGHTING FIXTURE (MOUNTING HEIGHT) PROPOSED LIGHTING INTENSITY (FOOTCANDLES) PROPOSED AREA LIGHT PROPOSED BUILDING MOUNTED LIGHT PROPOSED LUMINAIRE SCHEDULE MANUFACTURERLLFDISTRIBUTIONSECURITY LIGHTINGQUANTITYLABELSYMBOL IES FILE A 2 FT 0.9MIRADA MEDIUM OUTDOOR LED AREA LIGHT (MRM) LSI MRM-LED012L0SIL-FT-40-70CRI-I LIGHTING REQUIREMENTS CODE SECTION REQUIRED PROPOSED § 25-14.2 MINIMUM ILLUMINATION LEVELS: PEDESTRIAN WALKWAYS - 0.9 FC PARKING AREAS - 2.0 FC 3.4 FC 1.5 FC

Page 6

HT (MRM) LSI MRM-LED012L0SIL-FT-40-70CRI-I LIGHTING REQUIREMENTS CODE SECTION REQUIRED PROPOSED § 25-14.2 MINIMUM ILLUMINATION LEVELS: PEDESTRIAN WALKWAYS - 0.9 FC PARKING AREAS - 2.0 FC 3.4 FC 1.5 FC (W) (W) WAIVER B 2 4F 0.9OPULENCE SMALL WALL MOUNT (OPS) LSI OPS-03L-4F-40K8 C 1 FTW 0.9MIRADA SMALL WALL SCONE (XWS) LSI XWS-LED-02L-FTW-30-80CRI PROPOSED 0.5 FC ISOMETRIC LINE (SITE) AFTON SAVITZ, P.E. NEW JERSEY LICENSE No. 57674 LICENSED PROFESSIONAL ENGINEER