Project Condition : Wonde Name r Smokehouse Testing No. Man loagt Project Run No. 60735150 . . . urbe 7 & Semi-Volatile Organics Ove ate Balance [D BIE Ao SW-846 Method 0010 dee 2640 Source Recovered ° Srghichowsr SOgk by C, Thyiy Moisture Determination Sample Recovery Checklist Imp No. } Contents | Vol {mL} | Configuration Initial We (g} Final We (2) __&” Rinse and brush probe and nozzle with 50°50 mixture of dichloromethane and a methanol into PNA bottle. : _| (4 a0 | Ys parate filter holder and place filter in clean pre-rinsed, glass pete dish, Complete SFR EX. f / Filt sample tabel 2 HO 100 Mod. GF & a G qd . ( Seal XAD trap ends. Complete XAO sample label. , g Ainse front half of filter holder three times with 50:50 muxture of dichloromethane 3 Ho 100 G/s C2 c Gg C O3, > and methanol into PNR bottle. Complete PNR sample label 7 Rinse coil condenser, back half of filter holder and all connecting glassware 4 . mod |G OF. z 6(e.3 between the filter and XAO three times with SO'S0 mixture of dichloromethane . 7 and methanol into the CR [condenser rinse) bottle. Complete CR sample label. 5 | Silica Gel] ~ 300g Mod. 7 ey { q 5z% 5 LZ oisassembie sample train. remove foil from XAD cartndge, wipe off excess water £ and weigh each impinger and XAD. Record the final weights in the Moisture 6 XAD Cartridge Kee) ») ‘a 3 {Sy 4 Determination section. Rewrap cartndge with foil, attach label and place in bag. © Note conditson of the silica gel impinger. 2Q% spent Sample Log Pour contents of first impinger (condensate) into the Imps (:mpinger catch) . bottle(s], Complete Cond sample label. Sample 10 Number Sample | Description; / Rinse the first mpinger and connecting glassware with 50 50 muxture of Container dichloromethane and methanol three times into the IR (umpinger rinse) borttle(s). ¢ lete (AL le label. Wondstka- 2} -M0010-Semis-PNR | 2some | ,froreane mplete (A sample ta Discard the contents of impingers 2, 3, and 4 Wondstk1- B i -M0010-Semis-Filt Petri Dish Fits Log samples into logbook and place in refrigerator or ice chest. lWwondstk1- {2 | -MO010-Semis-CR | 250m | "Qo" Notes Wondstkt -M0010-Semis-XAD | SE | xa0 Trap WondStk1 -M0010-Semis-Cond| 1. | (inger Catch Wondsuka- (2. \ -M0010-Semis-IR | 70m. | MmpinEer = - _ ROS-10; Semivolatile Organics by SW-846 Method 0010 Document Per EM SOP.030 Issued: May 2023 reviewed biennially

File revisions (1)