Show all pagesA=COM XAD Thermocouple Calibrations Calibrator: Fred Sanguedolce Reference Thermometer: TS 181717335 _ Calibration Date: 01/02/2024 Calibration Date: 01/23/2024 __ Nutech Dry Gas Meter TC: 80612 Calibration Date: 05/24/2023 Placed in Service: 2003-2015 Reference Barometer: TS 181729655 __ Calibration Date: 01/02/2024 Serial No.: NIA Barometric Pressure (in. Hg): 30.16 Manufacturer: Apex Instruments Part No.: GN8-15K Ambient Temperature (°F): 65.8 Thermocouple ID Ice Bath Ambient Air {Part ID) Actual Reference Difference Actual Reference Difference XAD-1 31 32.3 -1.3 65 65.8 -0.8 XAD-2 - - _- - - - XAD-3 31 32.3 -13 65 65.8 0.8 XAD-4 3 32.3 1.3 86 65.8 0.2 XAD-5 32 32.5 -05 65 65.8 08 XAD-6 32 32.5 -0.5 65 65.8 -0.8 XAD-7 31 32.5 -15 65 65.8 0.8 XAD-8 _- - _- - _- - XAD-9 - -— _ - _ - XAD-10 32 32.5 0.5 65 65.8 0.8 XAD-11 _ -_ _ - _ - XAD-12 32 32.5 0.5 65 65.8 0.8 XAD-13 32 32.5 -0.5 65 65.8 -0.8 XAD-14 32 32.5 -0.5 65 65.8 -0.8 XAD-15 32 32.5 -0.5 66 65.8 0.2 XAD-16 32 32.5 -0.5 65 65.8 -0.8 XAD-17 32 32.5 -0.5 85 65.8 -0.8 XAD-18 34 32.3 13 65 65.8 0.8 Notes: — = currently not available for calibration