Show all pagesA5 3A TYP. EIFS DETAIL NTS A5 3B TYP. BRICK DETAIL NTS Outsulation® Plus MD System® NOTE: 1. DRYVIT RECOMMENDS THAT GROUND FLOOR APPLICATIONS AND ALL FACADES EXPOSED TO ABNORMAL STRESS, HIGH TRAFFIC, OR DELIBERATE IMPACT HAVE THE BASE COAT REINFORCED WITH PANZER® MESH PRIOR TO STANDARD OR STANDARD PLUS MESH. LOCATION OF HIGH IMPACT ZONES SHOULD BE INDICATED ON CONTRACT DRAWINGS. 2. AS AN OPTION DRYVIT DRAINAGE TRACK™ CAN BE USED AT SYSTEM TERMINATION AT GRADE, REFER TO OPMD 0.0.08 FOR CONFIGURATION. 3. DRYVIT DRAINAGE TRACK SHALL ONLY BE USED AT GRADE LEVEL TERMINATIONS. 4. 4GC TO BUDGET FOR "MANUFACTURE" DRYVIT TO REVIEW AND SIGN OFF ON THE INSTALLATION AND PROVIDE BOTH MATERIAL AND LABOR WARRANTY FOR THE INSTALLATIONS DRYVIT BASE COAT 2" EPS INSULATION BOARD R-10 CDX PLYWOOD SEE SECTIONS FOR THICKNESS DRYVIT AIR/WATER - RESISTIVE BARRIER COATING DRYVIT BASE COAT DRYVIT REINFORCING MESH EMBEDDED IN DRYVIT BASE COAT DRYVIT FINISH FRAMING BY OTHERS DRYVIT ADHESIVE IN VERTICAL NOTCHED TROWEL CONFIGURATION APPLIED TO BACK OF EPS DRYVIT DRAINAGE STRIP ADHERED WITH DABS OF DRYVIT AP ADHESIVE (SEE NOTES 2 AND 3) DRYVIT PANZER REINFORCING MESH DRYVIT BASE COAT ABOVE 8'-0 AFF THIS CAN BE OMITTED EVERYTHING BEHIND THE RAINS SCREEN IS BASED ON THE DRYVIT OUTSULATION DETAIL Water Flows Out All Brick naturally absorbs water TABS® Rain Screen TABS® II Panel System Patented TABS® Mortar Tie TABS® Supplied Masonry Veneer Water is directed through access holes Water flows down behind textured TABS® wall surface 1/2" to 1-1/4" THICK VENEER MORTAR/GROUT WITH TABS II MORTAR ADDITIVE PATENTED TABS II MORTAR TIE TABS PANEL SUPPORT TAB TABS II MASTIC- APPLIED IN DABS OR VERTICAL STRIPS - DO NOT APPLY HORIZONTALLY TABS RAIN SCREEN INSULATION BOARD (1/2" to 2" thickness) SUPPLIED BY TABS BUILDING WRAP SUPPLIED BY TABS SUBSTRATE TABS II NON-CORROSIVE TYPE FASTENER W/ WAFER-HEAD DESIGN INSULATION CHARTS VENEER THICKNESS INSULATION THICKNESS R-VALUE 1/2" VENEER UP TO 2" R-2.5 to R-10 3/4" VENEER UP TO 1.5" R-2.5 to R-7.5 1" VENEER UP TO 1" R-2.5 to R-5 PRODUCT DESCRIPTION INTENDED USE QUALITY OF STEEL PANEL NOMINAL PANEL THICKNESS CORROSION PROTECTION PANEL COATING EMBOSSED STEEL PANEL STARTER ANGLE THERMAL INSULATED PROTECTION PATENTED TABS II TIE SYSTEM MORTAR MIX MORTAR ADDITIVE ADHESIVE FASTENERS COMPONENT WARRANTY PANEL WARRANTY TABS TI TABS TI PLUS HEAVY DUTY STRUCTURAL
PANEL STARTER ANGLE THERMAL INSULATED PROTECTION PATENTED TABS II TIE SYSTEM MORTAR MIX MORTAR ADDITIVE ADHESIVE FASTENERS COMPONENT WARRANTY PANEL WARRANTY TABS TI TABS TI PLUS HEAVY DUTY STRUCTURAL GRADE .018/26 GAUGE G90 HOT DIPPED THERMAL SET INCLUDED TABS II 18 to 22 GAUGE R-2.5 to R-10 INCLUDED TYPE "S" TABS II TABS II TABS II NON-CORROSIVE FULL 25 YEARS FULL 50 YEARS PB-3 PROPOSED EXTERIOR ELEVATION SPEC'S MASTER FINISH SCHUDELE MHS AS NOTED Sheet No. Job No. Scale Drawn By Checked By Date G 141 ARCHITECTURE.LLC 21-0032 POPEYES LOUISIANNA KITCHEN 470 EAGLE ROCK AVE. WEST ORANGE - NJ RAG Revisions 2021-11-10 CT 13585 DE S5-0008497 DC AEC103027 MA 951751 MD 18745 NJ AI 15475 NH 04842 NY 039330 OH ARC.2018210 PA AR07639 VA 0401019058 KENILWORTH, NJ 07033 g141office@gmail.com 7419 ROBERT ANTHONY - 1 4 1 NCARB 84690 AIA 38640695 347908 .. 39 NORTH 11th STREET GRIMALDI . - . - . - . - .
File revisions (1)
- Sep 29, 2026
427fad3acc344,098,788 bytes