Supporting Documentation · Jan 22, 2025
240917_40 ERW Full Civil Set
e7471db6a40cf8a4d4c7251662bf1ca2b2f4c749440a4ab6679469e5cac474dfIndexed text · page 6
Show all pages25 FT SIDE YARD SETBACK 25 FT SIDE YARD SETBACK 50 FT REAR YARD SETBACK X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 40 FT FRONT YARD SETBACK LIMIT OF DISTURBANCE: ±81,824 SF (±1.87 AC) (LOD IS SHOWN 2' OFFSET FOR GRAPHICAL PURPOSES) EXISTING TEMPORARY CONSTRUCTION ENTRANCE 626 627 627 626 D 624 619 618 617 605 606 609 610 610 609 611 612 613 616 615 614 619 619 618 617 616 615 614 612 611 614 615 616 617 618 620 622 622 623 621 620 625 624 621 626 607 608 613 619 TW: 611.00 BW: 610.00 TW: 619.00 BW: 619.00 TW: 619.00 BW: 616.50 TW: 616.00 BW: 613.50 TW: 611.00 BW: 608.50 TW: 613.50BW: 613.00 TW: 615.50 BW: 613.00 TW: 619.00 BW: 616.50 TW: 619.00 BW: 619.00 EL. 627.5 EL. 627.5 EL. 627.5 EL. 627.5 EL. 627.5 EL. 626.50 EL. 626.50 D PROP. SILT FENCE (SILT FENCE IS SHOWN 2' OFFSET FOR GRAPHICAL PURPOSES) G EAGLE RIDGE (50') WAY PROP. INLET FILTER (TYP.) PROP. SCOUR HOLE 626 627 627 626 D 624 619 618 617 605 606 609 610 610 609 611 612 613 616 615 614 619 619 618 617 616 615 614 612 611 614 615 616 617 618 620 622 622 623 621 620 625 624 621 626 607 608 613 619 TW: 611.00 BW: 610.00 TW: 619.00 BW: 619.00 TW: 619.00 BW: 616.50 TW: 616.00 BW: 613.50 TW: 611.00 BW: 608.50 TW: 613.50BW: 613.00 TW: 615.50 BW: 613.00 TW: 619.00 BW: 616.50 TW: 619.00 BW: 619.00 EL. 627.5 EL. 627.5 EL. 627.5 EL. 627.5 EL. 627.5 EL. 626.50 EL. 626.50 D PROP. LOCATION OF SOIL STOCKPILE 1. ALL SOIL EROSION AND SEDIMENT CONTROL PRACTICES ON THIS PLAN WILL BE CONSTRUCTED IN ACCORDANCE WITH THE “NEW JERSEY STANDARDS FOR SOIL EROSION AND SEDIMENT CONTROL” 7TH EDITION LAST REVISED DECEMBER 2017. THESE MEASURES WILL BE INSTALLED PRIOR TO ANY MAJOR SOIL DISTURBANCE OR IN THEIR PROPER SEQUENCE AND MAINTAINED UNTIL PERMANENT PROTECTION IS ESTABLISHED. 2. ALL SOIL TO BE EXPOSED OR STOCKPILED FOR A PERIOD OF GREATER THAN 14 DAYS, AND NOT UNDER ACTIVE CONSTRUCTION, WILL BE TEMPORARILY SEEDED AND HAY MULCHED OR OTHERWISE PROVIDED WITH VEGETATIVE COVER. THIS TEMPORARY COVER SHALL BE MAINTAINED UNTIL SUCH TIME WHEREBY PERMANENT RE-STABILIZATION IS ESTABLISHED. 3. SEEDING DATES: THE FOLLOWING SEEDING DATES ARE RECOMMENDED TO BEST ESTABLISH PERMANENT VEGETATIVE COVER WITHIN MOST LOCATIONS IN THE HEPSCD: SPRING - 3/1-5/15 AND FALL - 8/15 - 10/1 4. SEDIMENT FENCES ARE TO BE PROPERLY TRENCHED
SEEDING DATES ARE RECOMMENDED TO BEST ESTABLISH PERMANENT VEGETATIVE COVER WITHIN MOST LOCATIONS IN THE HEPSCD: SPRING - 3/1-5/15 AND FALL - 8/15 - 10/1 4. SEDIMENT FENCES ARE TO BE PROPERLY TRENCHED AND MAINTAINED UNTIL PERMANENT VEGETATIVE COVER IS ESTABLISHED 5. ALL STORM DRAINAGE INLETS SHALL BE PROTECTED BY ONE OF THE PRACTICES ACCEPTED IN THE STANDARDS, AND PROTECTION SHALL REMAIN UNTIL PERMANENT STABILIZATION HAS BEEN ESTABLISHED. STORM DRAINAGE OUTLET POINTS SHALL BE PROTECTED AS REQUIRED BEFORE THEY BECOME FUNCTIONAL. 6. MULCH MATERIALS SHALL BE UN-ROTTED SMALL GRAIN STRAW APPLIED AT THE RATE OF 70 TO 90 POUNDS PER 1,000 SQUARE FEET AND ANCHORED WITH A MULCH ANCHORING TOOL, LIQUID MULCH BINDERS, OR NETTING TIE DOWN. OTHER SUITABLE MATERIALS MAY BE USED IF APPROVED BY THE SOIL CONSERVATION DISTRICT. 7. ALL EROSION CONTROL DEVICES SHALL BE PERIODICALLY INSPECTED, MAINTAINED AND CORRECTED BY THE CONTRACTOR. ANY DAMAGE INCURRED BY EROSION SHALL BE RECTIFIED IMMEDIATELY. 8. THE HUDSON-ESSEX-PASSAIC SOIL CONSERVATION DISTRICT WILL BE NOTIFIED IN WRITING AT LEAST 48 HOURS PRIOR TO ANY SOIL DISTURBING ACTIVITIES. FAX - (862) 333-4507 OR EMAIL - INFORMATION@HEPSCD.ORG 9. THE APPLICANT MUST OBTAIN A DISTRICT ISSUED REPORT-OF-COMPLIANCE PRIOR TO APPLYING FOR THE CERTIFICATE OF OCCUPANCY OR TEMPORARY CERTIFICATE OF OCCUPANCY FROM THE RESPECTIVE MUNICIPALITY, NJ - DCA OR ANY OTHER CONTROLLING AGENCY. CONTACT THE DISTRICT AT 862-333-4505 TO REQUEST A FINAL INSPECTION, GIVING ADVANCED NOTICE UPON COMPLETION OF THE RESTABILIZATION MEASURES. A PERFORMANCE DEPOSIT MAY BE POSTED WITH THE DISTRICT WHEN WINTER WEATHER OR SNOW COVER PROHIBITS THE PROPER APPLICATION OF SEED, MULCH, FERTILIZER OR HYDRO-SEED. 10. PAVED ROADWAYS MUST BE KEPT CLEAN AT ALL TIMES. DO NOT UTILIZE A FIRE OR GARDEN HOSE TO CLEAN ROADS UNLESS THE RUNOFF IS DIRECTED TO A PROPERLY DESIGNED AND FUNCTIONING SEDIMENT BASIN. WATER PUMPED OUT OF THE EXCAVATED AREAS CONTAINS SEDIMENTS THAT MUST BE REMOVED PRIOR TO DISCHARGING TO RECEIVING BODIES OF WATER USING REMOVABLE PUMPING STATIONS, SUMP PITS, PORTABLE SEDIMENTATION TANKS AND/OR SILT CONTROL BAGS. 11. ALL SURFACES HAVING LAWN OR LANDSCAPING AS FINAL COVER ARE TO BE PROVIDED TOPSOIL PRIOR TO RE-SEEDING, SODDING OR PLANTING. A DEPTH OF 5 INCHES FIRM IN PLACE IS REQUIRED, AS PER THE STANDARDS FOR TOPSOILING AND LAND GRADING, LAST REVISED DECEMBER
AL COVER ARE TO BE PROVIDED TOPSOIL PRIOR TO RE-SEEDING, SODDING OR PLANTING. A DEPTH OF 5 INCHES FIRM IN PLACE IS REQUIRED, AS PER THE STANDARDS FOR TOPSOILING AND LAND GRADING, LAST REVISED DECEMBER 2017. 12. ALL PLAN REVISIONS MUST BE SUBMITTED TO THE DISTRICT FOR PROPER REVIEW AND APPROVAL. 13. A CRUSHED STONE WHEEL CLEANING TRACKING-PAD IS TO BE INSTALLED AT ALL SITE EXITS USING 2 ½ -1”CRUSHED ANGULAR STONE (ASTM 2 OR 3) TO A MINIMUM LENGTH OF 50 FEET AND MINIMUM DEPTH OF 6”. ALL DRIVEWAYS MUST BE PROVIDED WITH CRUSHED STONE UNTIL PAVING IS COMPLETE. 14. STEEP SLOPES INCURRING DISTURBANCE MAY REQUIRE ADDITIONAL STABILIZATION MEASURES. THESE “SPECIAL” MEASURES SHALL BE DESIGNED BY THE APPLICANT'S ENGINEER AND BE APPROVED BY THE SOIL CONSERVATION DISTRICT. 15. THE HUDSON-ESSEX-PASSAIC SOIL CONSERVATION DISTRICT SHALL BE NOTIFIED, IN WRITING, FOR THE SALE OF ANY PORTION OF THE PROJECT OR FOR THE SALE OF INDIVIDUAL LOTS. NEW OWNERS' INFORMATION SHALL BE PROVIDED. ADDITIONAL MEASURES DEEMED NECESSARY BY DISTRICT OFFICIALS SHALL BE IMPLEMENTED AS CONDITIONS WARRANT. HUDSON-ESSEX-PASSAIC SOIL CONSERVATION DISTRICT NOTES (DECEMBER 2017) DISTURBANCE THIS SITE IS PREVIOUSLY DEVELOPED AND UNWOODED, LYING WITHIN A METROPOLITAN PLANNING AREA AND IS THEREFORE EXEMPT FROM SOIL COMPACTION TESTING. N S E W NORTH 30 30 60 SCALE : 1" = 30' 0 SELECT LINEAR UNIT OF MEASURE Engineering & Design Architecture, LandscapeArchitecture, Surveying, CT P.C.Engineering& Design, Engineering & Design Architecture, LandscapeArchitecture, Surveying, CT P.C.Engineering& Design, UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY OR ENGINEERING MAP BEARING A LICENSED LAND SURVEYOR OR PROFESSIONAL ENGINEER IS A VIOLATION OF SECTION 7209, SUB-DIVISION 2, OF THE NEW YORK STATE EDUCATION LAW.ONLY MAPS WITH THE LAND SURVEYOR OR PROFESSIONAL ENGINEER'S SEAL ARE GENUINE TRUE AND CORRECT COPIES OF THE LAND SURVEYOR OR PROFESSIONAL ENGINEER’S ORIGINAL WORK AND OPINION. REV DATE DRAWN BY DESCRIPTION SHEET NUMBER: SCALE: PROJECT NUMBER: DRAWN BY:DATE: DRAWING NAME: CHECKED BY: SHEET TITLE: PROTECT YOURSELF Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied
tion contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. ALL STATES REQUIRE NOTIFICATION OF EXCAVATORS, DESIGNERS, OR ANY PERSON PREPARING TO DISTURB THE EARTH'S SURFACE ANYWHERE IN ANY STATE FOR STATE SPECIFIC DIRECT PHONE NUMBERS VISIT: WWW.CALL811.COM C-SESC 2024\24006174A\Engineering\Site Plans\C-SESC.dwg\C-X.XX-SOIL EROSION-40 By: JWAGNER R REVIEWED BY: NOTE: DO NOT SCALE DRAWINGS FOR CONSTRUCTION. CITY OF PITTSBURGH DEPARTMENT OF CITY PLANNINGAPPROVED: _______________________CITY PLANNING COMMISSION_______________________CHAIRMAN ATTEST: ______________________________________________SECRETARY Phone: www.colliersengineering.com C O N S U L T I N G ENGINEERS + SURVEYING PRELIMINARY & FINAL MAJOR SITE PLAN THE WAYMAKER LLC PROPOSED RESIDENTIAL IMPROVEMENTS BLOCK 106 LOT 20.03 TOWNSHIP OF WEST ORANGE ESSEX COUNTY NEW JERSEY AS SHOWN 9/17/24 MMN JF 24006174A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ___________________________ FOR PTH WOODCLIFF LAKE 300 Tice Boulevard Suite 101 Woodcliff Lake, NJ 07677 845.352.0411 COLLIERS ENGINEERING & DESIGN, INC. DOING BUSINESS AS MASER CONSULTING Doing Business as OF 8 Jesse Cokeley NEW JERSEY LICENSED PROFESSIONAL ENGINEER LICENSE NUMBER: GE54006 COLLIERS ENGINEERING & DESIGN, INC. N.J. C.O.A. #: 24GA27986500 SOIL EROSION & SEDIMENT CONTROL PLAN 6 LEGEND = LIMIT OF = INLET PROTECTION = CONSTRUCTION ENTRANCE = STAGING AREA THIS PLAN TO BE UTILIZED FOR EROSION CONTROL PURPOSES ONLY.1. INSTALL PERIMETER SILT FENCE , CONSTRUCTION FENCE, INLET FILTERS, STABILIZED CONSTRUCTION ENTRANCE AND ALL OTHER SOIL EROSION AND SEDIMENT CONTROL FEATURES. ( 1 WEEK) 2. PERFORM DEMOLITION IN ACCORDANCE WITH THE DEMOLITION PLAN. CLEAR AND ROUGH GRADE FOR BUILDING AND ALL OTHER STRUCTURES REQUIRING EXCAVATION. ( 1 MONTH) 3. EXCAVATE FOR BUILDING FOUNDATIONS AND COMMENCE BUILDING CONSTRUCTION. ( 8-12 MONTHS) 4. INSTALL CURBING, DRAINAGE IMPROVEMENTS AND PERFORM FINAL GRADING OF THE SITE. (3 WEEKS) 5. INSTALL PAVEMENT BASE COURSES. (1 WEEK) 6. INSTALL FINISHED PAVEMENT COURSES AND CONCRETE PAVEMENT. ( 2 WEEKS) 7. INSTALL LANDSCAPING AND PERMANENTLY STABILIZE
FINAL GRADING OF THE SITE. (3 WEEKS) 5. INSTALL PAVEMENT BASE COURSES. (1 WEEK) 6. INSTALL FINISHED PAVEMENT COURSES AND CONCRETE PAVEMENT. ( 2 WEEKS) 7. INSTALL LANDSCAPING AND PERMANENTLY STABILIZE ALL DISTURBED AREAS (1 WEEK) 8. REMOVE ALL TEMPORARY SEDIMENT AND EROSION CONTROL MEASURES. ( 1 WEEK) SEQUENCE OF CONSTRUCTION = SILT FENCE
File revisions (1)
- Sep 29, 2026
e7471db6a40c9,016,596 bytes