241220_42 ERW Waymaker Printed 12/20/2024Prepared by Colliers Engineering & Design Page 4HydroCAD® 10.20-5c s/n 04431 © 2023 HydroCAD Software Solutions LLC Area Listing (selected nodes) Area (acres) CN Description (subcatchment-numbers) 1.601 74 >75% Grass cover, Good, HSG C (PR 1A-P, PR 1B-P, PR 2-P) 0.643 89 Gravel roads, HSG C (PR 1A-P, PR 1B-P, PR 2-P) 0.355 98 Paved parking, HSG C (PR 1B-I) 0.492 98 Roofs, HSG C (PR 1B-I) 3.092 84 TOTAL AREA This document was created by an application that isn’t licensed to use novaPDF. Purchase a license to generate PDF files without this notice.