Supporting Documentation · Jul 2, 2025
24 010_issued for zoning_REVISED_JULY2025
2de5a5632686ad5a1adb45c6022f7556d0eae0c4cb9a9a0f88009041812a52d3Indexed text · page 3
Show all pagesREVISIONS: # DESCRIPTION: DATE: ISSUED FOR PERMITS 4/10/2024 ISSUED FOR ZONING 6/26/2024 REVISED PER LIST OF CONDITIONS 6/12/20251 NOTE: THIS DRAWING IS APPROVED ONLY FOR THE SCOPE OF WORK INDICATED ON THE DRAWINGS. ALL OTHER MATTERS SHOWN ARE NOT TO BE RELIED UPON OR CONSIDERED AS EITHER BEING APPROVED BY THIS ARCHITECT AND HIS CONSULTANTS OR IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS 48" x 30" PARKING SPACE 60" TURNING RADIUS 48" x 30" PARKING SPACE 60" TURNING RADIUS 48" x 30" PARKING SPACE 30" x 48" SINK CLR 30" x 48" SINK CLR 9'-6" 8'-6" 8'-6" 8'-6" 5'-0" 8'-6" 10'-9" 4'-0" 10'-8" 5'-0" 5'-0" 10'-0" 15'-8" 8'-6"8'-6"8'-6"5'-1" UP OFFICE LAB #1 LAB #2 LAB #3 LAB #4 LAB #5 10'-7"7'-6" 7'-6" PHLEBOTOMIST STORAGE TOILET TOILET WAITING OFFICE SPACE BREAK ROOM TOILET TOILET HALL HALL RECEPTION 6'-8" JAN CL 5'-6" 4'-0" 5'-0" 3'-0" JAN SINK 10'-0" EXISTING MASONRY BLOCK WALL. MAINTAIN FIRE-RATING. NEW STEEL LINTEL. SEE LINTEL SCHEDULE NEW STEEL LINTEL. SEE LINTEL SCHEDULE NEW STOREFRONT AS SELECTED BY OWNER NEW STOREFRONT AS SELECTED BY OWNER NEW STEEL LINTEL. SEE LINTEL SCHEDULE NEW STEEL LINTEL. SEE LINTEL SCHEDULE EX. EX. EX. EX. EX. COLUMNS TO REMAIN EX. COLUMNS TO REMAIN 44" GFI 44" GFI 44" GFI 44" GFI 44" GFI 44" GFI 44" GFI 44" GFI44" GFI 44" GFI 44" GFI 44" GFI 44" GFI 44" GFI 44" GFI 44" GFI 44" GFI 44" GFI 44" GFI 44" GFI 44" GFI 44" GFI COORDINATE OPENING SIZE AND LOCATION WITH OWNER 1'-0" MIN WH WH FURNACE 44" GFI FURNACE GAS CHASE E.P. E.P. EXIT DISCHARGE LIGHT EXIT DISCHARGE LIGHT EXIT DISCHARGE LIGHT EXIT DISCHARGE LIGHT EXIT DISCHARGE LIGHT EXIT DISCHARGE LIGHT EXIT DISCHARGE LIGHT BREAK ROOM EXIT DISCHARGE LIGHT EXIT DISCHARGE LIGHT RESIDENTIAL TRASH ENCLOSURE SEE CIVIL DRAWINGS FOR ADDITIONAL INFO H.C. LIFT NEW RAILING NEW RAILING NEW RAILING DN DN COMMERCIAL TRASH ENCLOSURE SEE CIVIL DRAWINGS FOR ADDITIONAL INFO PER CONDITIONS- NO PORTION OF BUILDING SHALL BE USED AS AN EVENT SPACE. SECOND OFFICE SPACE MAY NOT BE USED FOR MEDICAL USE. FIRE ESCAPE ABOVE DROP LADDER ABOVE DROP LADDER ABOVE FIRE ESCAPE ABOVE MARK L-1 L-2 L-3 L-4 (1) WT10.5x66 FOR 12" WALL THICKNESS. SIZE (1) ANGLE 6x3 x FOR EACH 4" WALL THICKNESS (LLV). 52/1 /16 (1) ANGLE 6x3 x FOR EACH 4" WALL THICKNESS (LLV). 1 / 2 2/1 MINIMUM HEIGHT ABOVE LINTEL - 8 FEET. FOR OPENINGS UP TO 16'-0". PROVIDE 8" BEARING, MINIMUM. FOR OPENINGS 8'-0" TO 10'-0". FOR OPENINGS UP TO
) ANGLE 6x3 x FOR EACH 4" WALL THICKNESS (LLV). 1 / 2 2/1 MINIMUM HEIGHT ABOVE LINTEL - 8 FEET. FOR OPENINGS UP TO 16'-0". PROVIDE 8" BEARING, MINIMUM. FOR OPENINGS 8'-0" TO 10'-0". FOR OPENINGS UP TO 6'-0". PROVIDE 8" BEARING, MINIMUM. REMARKS FOR OPENINGS 6'-0" TO 8'-0". PROVIDE 8" BEARING, MINIMUM. FILL CELLS SOLID WITH GROUT FOR 3 COURSES BELOW BEARING PLATE. PROVIDE 10" BEARING, MINIMUM. FILL CELLS SOLID WITH GROUT FOR 3 COURSES BELOW BEARING PLATE. SECTIONS LINTEL SCHEDULE (1) ANGLE 5x3 1/2 x 5/16 FOR EACH 4" WALL THICKNESS (LLV). TOOTH IN NEW WHOLE BLOCK INTO MASONRY OPENING ELIMINATING VERTICAL JOINTS OUTLINING ORIGINAL OPENING FOR ALL OPENINGS, TOOTH NEW CORNER BLOCK INTO MASONRY. INSERT DOOR FRAME ANCHORS. UP TO 40" MASONRY OPENINGS: PRECAST CONCRETE LINTEL FULL THICKNESS OF WALL WITH 4" BEARING. 4" DOOR FRAME HEAD IN BLOCK WALLS, TYPICAL. TENANT # 1 TENANT # 2SHARED APT # 1 APT # 2 APT # 3 APT # 4 APT # 5 APT # 6 APT #7 TENANT # 1 TENANT # 2 APT # 1 APT # 2 APT # 3 APT # 4 APT # 5 APT # 6 APT #7 COORDINATE ELECTRICAL METERS WITH SERVICE PROVIDER SHARED ELECTRICAL PANEL DISONNECT SWITCH COORDINATE GAS METERS WITH SERVICE PROVIDER GAS CHASE 1/2" GYPSUM BOARD ON 2"X4" STUDS AT 16" O.C. WITH R-13 INSULATION. 8" CMU WALL 1/2" AIR GAP 2"x4" P.T. SOLE PLATE, TYP. 5" BLOCK FURRING WALLS (EXTERIOR) 4 EXTERIOR FINISH FIRST FLOOR CELLAR PLAN CONSTRUCTION PLAN DRAWING TITLE: JASON PEIST, AIA - ARCHITECT CHANGE OF USE- ADD A LEVEL 172-174 MAIN ST WEST ORANGE, NJ 07052 BLOCK 89, LOT 6 ESSEX COUNTY ARCHITECTURAL LICENSE #: NJ# 21AI02035200 NY# 039598 PA# RA410300 CT# ARI.0015695 RI# ARC.0005736 drawings, specifications & other documents, both paper copies and in electronic form, prepared by jason peist and consultants are instruments of service for use solely for this project. they may not be used for any purposes beyond the scope of this contract without written permission from jason peist. unlawful use of instruments of service shall be prosecuted to the full extent of the law. © COPYRIGHT 2024 JASON PEIST ARCHITECT, LLC 171 BROAD ST. MATAWAN, NJ 07747 732-379-0743 | info@jasonpeist.com 4/10/24 DATE: JOB NUMBER: SCALE: AS NOTED DRAWN BY: J.R.P. DRAWING NUMBER A-101 OF 24-010 83 SHEET: 1 SCALE: 1/4"=1'-0" FIRST FLOOR PLAN A NOT TO SCALE MASONRY WALL- NEW DOOR B NOT TO SCALE MASONRY WALL- INFILL 1 1 1
File revisions (1)
- Sep 29, 2026
2de5a56326862,766,758 bytes