2025-08-21_Pipe Capacity Calculations NOAA 24-hr D 25-Year Rainfall=6.44" Prepared by Stonefield Engineering & Design HydroCAD® 10.20-5c s/n 06682 © 2023 HydroCAD Software Solutions LLC Printed 8/21/2025 Page 7 Summary for Subcatchment PIPE 5: Pipe 5 Drainage Runoff = 1.45 cfs @ 12.09 hrs, Volume= 4,845 cf, Depth= 6.20" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv., Time Span= 0.00-72.00 hrs, dt= 0.01 hrs NOAA 24-hr D 25-Year Rainfall=6.44" Area (sf) 9,375 9,375 * CN 98 98 Description impervious Area 100.00% Impervious Area Subcatchment PIPE 5: Pipe 5 Drainage Hydrograph Runoff 1.45 cfs Flow (cfs) 1 0 0 2 4 NOAA 24-hr D 25-Year Rainfall=6.44" Runoff Area=9,375 sf Runoff Volume=4,845 cf Runoff Depth=6.20" Tc=0.0 min CN=0/98 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours)