Supporting Documentation · May 28, 2026
Geotechnical Engineering Report Addendum No 1 Results of Testing 01 29 2025 submission
28bb996689501483d1d8b722cf1ba5cac10a6dddb28205b7927653fdf835c6ceIndexed text · page 1
Show all pagesGeotechnical Construction Materials Environmental Facilities January 29, 2025 Ms. Rachael Dickinson Pre-Construction Project Manager Mavis Tire Supply, LLC 200 Summit Lake Drive, Suite 350 Valhalla, NY 10595 ECS Project Number: 44:2100-A Reference: Addendum No. 1 - Results of Test Pit Excavation and Infiltration Testing Mavis Store #2296 460 Prospect Avenue, West Orange, New Jersey Dear Ms. Dickinson: ECS Mid-Atlantic, LLC (ECS) is pleased to present the interpreted subsurface profiles and results from the test pits excavations and infiltration testing completed at the referenced project site location. The work described herein was performed to supplement the previous subsurface exploration executed under ECS project No. 44:2100. The purpose of the explorations was: To perform infiltration testing, the results of which will be considered in the design of the potential stormwater management (SWM) facilities. To further evaluate the existing fill materials and to better understand the make-up and depth of these materials to further determine suitability for support of the foundations and/or if undercuts will be necessary. Our services were provided in general accordance with the scope provided to Mavis in email correspondence dated December 12, 2024 (ECS Proposal No. 44:2237-GP), which was authorized via email on December 16, 2024. PROJECT UNDERSTANDING The project site is located at 460 Prospect Avenue, West Orange, Essex County, New Jersey. In discussions with Mavis, further evaluation of the fill material within the footprint of the proposed retail auto service building was required. In addition, as understood from information provided by Mavis, a stormwater management (SWM) facility is proposed as part of the overall site development. Limited details regarding the SWM facility were available at the time of testing and the infiltration testing locations were selected in the general location of the SWM facility as approved by Mavis. 2
the SWM facility were available at the time of testing and the infiltration testing locations were selected in the general location of the SWM facility as approved by Mavis. 2 EXECUTIVE DRIVE, SUITE 11, MOORESTOWN, NJ 08057 T: (609) 832-3910 F: (484) 840-5586 ECS Florida, LLC ECS Mid-Atlantic, LLC ECS Midwest, LLC ECS Pacific, Inc. ECS Southeast, LLC ECS Southwest, LLP ECS New York Engineering, PLLC – An Associate of ECS Group of Companies www.ecslimited.com “ONE FIRM. ONE MISSION.”
File revisions (1)
- Sep 29, 2026
28bb996689508,026,368 bytes