Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Dec 3, 2025

76 Ashland West Orange NJ_Planning Bd Submittal_REV 1_112125_SS

Preserved file SHA-256e5085518966adb5912962e2090f499ae223299724a0f20c3d70a72947ce79666

Indexed text

Page 1

COVER SHEET, GENERAL NOTES CS-1.0 REV# DISTRIBUTION DATE PLANNING BD. SUBMITTAL 04/30/2025 SEAL NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED REVIEWED BY: SHEET NO. DATE: DRAWN BY: PROJECT NO. SCALE: PROJECT LOCATION: SHEET TITLE: 17-2023 06/30/23 SHEET NO. MS GS AS NOTED CANNABIS CULTIVATION BUILDING RENOVATION 76 Ashland Avenue West Orange, NJ P.O. BOX #51 NUTLEY, NJ 07110 PH: 973-901-6976 WWW.BERSAARCHITECTS.COM CONSULTANTS COPYRIGHT 2023 1 ENGINEER AND PLANNER 11/21/2025 COMMENTS CANNABIS CULTIVATION AND MANUFACTURING FACILITY BUILDING RENOVATION 76 ASHLAND AVENUE WEST ORANGE, NJ 07052 APPLICABLE CODES: ALL WORK SHALL BE DESIGNED AND COMPLETED IN ACCORDANCE WITH THE FOLLOWING CODES: BUILDING: NEW JERSEY UNIFORM CONSTRUCTION CODE 2021 INTERNATIONAL BUILDING CODE N.J. EDITION (N.J.A.C. 5:23-3.14) ACCESSIBILITY: BARRIER FREE SUBCODE (CHAPTER 11 OF IBC 2018 & N.J.A.C. 5:23-7) ICC/ANSI A117.1 - 2017 ENERGY: ASHRAE 90.1-2019 ENERGY SUBCODE (N.J.A.C. 5:23-3.18) MECHANICAL: 2021 INTERNATIONAL MECHANICAL CODE (IMC) (N.J.A.C. 5:23- 3.20) ELECTRICAL: 2020 NATIONAL ELECTRIC CODE NFPA 70 (N.J.A 5:23- 3.16) PLUMBING: 2021 NATIONAL STANDARD PLUMBING CODE N.J. ED. (N.J.A.C. 5:23-3.15) OTHER: REHABILITATION SUBCODE - NJUCC SUBCH. 6 (N.J.A.C. 5:23-6) SUMMARY OF WORK: 1. RENOVATION OF EXISTING 3-STORY COMMERCIAL BUILDING. 2. EXISTING SHELL BUILDING TO REMAIN WITH STRUCTURAL UPGRADES FOR STABILITY. FIT OUT TO INCLUDE: DEMOLITION OF EXISTING INTERIOR WALLS, DOORS, FINISHES, FIXTURES, WINDOWS (AS SPECIFIED), ELECTRICAL, MECHANICAL, PLUMBING, AND FIRE ALARM SYSTEM. NEW EXTERIOR ADDITION TO BE LOCATED UNDER EXISTING CANOPY, NEW EXTERIOR DOOR OPENINGS, NEW EXTERIOR WALL INFILLS, INTERIOR PARTITIONS, DOORS, FINISHES, FIXTURES, ELECTRICAL, MECHANICAL, PLUMBING, SPRINKLER SYSTEM, AND FIRE ALARM SYSTEM TO BE INSTALLED. EXISTING ELECTRICAL INCOMING SERVICE TO REMAIN AND BE REUSED, EXISTING DOMESTIC WATER SERVICE TO BE REPLACED, NEW SPRINKLER WATER SERVICE, EXISTING GAS METER TO BE RELOCATED AND REPLACED. 3. SEE DRAWINGS FOR FULL SCOPE OF WORK FOR ENTIRE PROJECT. THIS SUMMARY DOES NOT CHANGE OR SUPERCEDE WHAT IS SHOWN IN THE DRAWINGS. BUILDING DATA : A. LOT/BLOCK: LOT 22.01- BLOCK 62 B. ZONING DISTRICT: I - INDUSTRIAL ZONE C. OCCUPANCY: F-1 MODERATE-HAZARD FACTORY INDUSTRIAL D. USE GROUP: CANNABIS CULTIVATION AND MANUFACTURING FACILITY E. CONSTRUCTION TYPE: TYPE 3B (IBC TABLE 601 AND

Page 1

ZONING DISTRICT: I - INDUSTRIAL ZONE C. OCCUPANCY: F-1 MODERATE-HAZARD FACTORY INDUSTRIAL D. USE GROUP: CANNABIS CULTIVATION AND MANUFACTURING FACILITY E. CONSTRUCTION TYPE: TYPE 3B (IBC TABLE 601 AND SECTION 602) F. SPRINKLERED: YES G. GROSS FLOOR AREA: FIRST FLOOR: 6,103 SQ. FT. SECOND FLOOR: 7,081 SQ. FT. THIRD FLOOR: 5,616 SQ. FT. TOTAL SQUARE FOOTAGE (GROSS): 18,800 SQ. FT. FIRE RESISTANCE RATING OF BUILDING ELEMENTS (IBC TABLE 601): A. STRUCTURAL FRAME........................................................ 0 HR B. EXTERIOR BEARING WALLS AND PARTITIONS.............. 2 HR C. INTERIOR BEARING WALLS AND PARTITIONS............... 0 HR D. EXTERIOR NON-BEARING WALLS AND PARTITIONS.... 2 HR(PER IBC TABLE 705.5) E. INTERIOR NON-BEARING WALLS AND PARTITIONS..... 0 HR F. FLOOR CONSTRUCTION................................................... 0 HR G. ROOF CONSTRUCTION..................................................... 0 HR OCCUPANT LOAD : THIS CANNABIS CULTIVATION AND MANUFACTURING FACILITY WILL HAVE NO MORE THAN TEN (10) EMPLOYEES. 1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL EXISTING JOB CONDITIONS, DIMENSIONS, AND QUANTITY OF WORK. ANY DISCREPANCIES BETWEEN "TRUE" EXISTING CONDITIONS AND REPRESENTATIONS THEREOF IN THE CONTRACT DOCUMENTS AND DRAWINGS ARE TO BE BROUGHT TO THE OWNER'S ATTENTION PRIOR TO THE COMMENCEMENT OF WORK. THE COMMENCEMENT OF WORK ON ANY ROOM SURFACE OR DETAILS MEANS ACCEPTANCE OF THE SAME BY THE CONTRACTOR AS ACCEPTABLE FOR NEW WORK AND CONSISTENT WITH CONTRACT DOCUMENTS. 2. PROVIDE ALL MATERIALS AS NEW UNLESS NOTED AS "EXISTING" TO REMAIN. ALL ITEMS SCHEDULED TO BE REUSED OR RELOCATED SHALL BE CAREFULLY REMOVED, STORED AND REINSTALLED AS PER THE CONTRACT DOCUMENTS. 3. EXAMINE ALL EXISTING SURFACES AND EXISTING MATERIALS TO REMAIN INCLUDING BUT NOT NECESSARILY LIMITED TO, MASONRY WALLS, CONCRETE FLOORS AND CEILINGS. NOTIFY THE OWNER OF ANY DEFECTS WHICH ARE CONSIDERED DETRIMENTAL OR UNACCEPTABLE TO THE PROPER INSTALLATION OF NEW WORK. COMMENCEMENT OF WORK WILL BE CONSIDERED ACCEPTANCE OF EXISTING CONDITIONS, ITEMS AND SURFACES BY THE CONTRACTOR. 4. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ACCURATE QUANTITIES OF ALL ITEMS TO BE REPLACED. 5. ALL ELECTRICAL OUTLETS, PLUMBING FIXTURES, PLUMBING, REGISTERS AND GRILLES SHOWN ON THE DRAWINGS ARE INDICATED TO ESTABLISH THE GENERAL LOCATION FOR SUCH COMPONENTS . EACH CONTRACTOR SHALL REFER

Page 1

D. 5. ALL ELECTRICAL OUTLETS, PLUMBING FIXTURES, PLUMBING, REGISTERS AND GRILLES SHOWN ON THE DRAWINGS ARE INDICATED TO ESTABLISH THE GENERAL LOCATION FOR SUCH COMPONENTS . EACH CONTRACTOR SHALL REFER TO THE DRAWINGS FOR THE EXACT LAYOUT OF EACH RESPECTIVE ITEM. BUILDING/WALL SECTION DETAIL REFERENCE DRAWING NUMBER LEVEL LINE DOOR NUMBER ROOM NAME ROOM NUMBERCOLUMN DRAWING NUMBER WINDOW TYPE REVISION REF. GRID EXISTING BUILDING LOCATION 76 ASHLAND AVENUE XXX SALES AREA XXX CEILING TYPE CEILING HEIGHT DWG # DRAWING TITLE ISSUE REV-1 REV-2 CS-1.0 COVER SHEET, GENERAL NOTES 11/21/2025 1 OF 2 MINOR SITE PLAN, LANDSCAPE AND LIGHTING 11/21/2025 2 OF 2 LIGHTING PLAN A-1.0 PROPOSED PLAN: FIRST FLOOR 11/21/2025 A-1.1 PROPOSED PLAN: SECOND FLOOR A-1.2 PROPOSED PLAN: THIRD FLOOR 11/21/2025 A-2.0 PROPOSED EXTERIOR ELEVATIONS 11/21/2025 A-2.0 PROPOSED EXTERIOR ELEVATIONS 11/21/2025 A-3.0 PROPOSED 3D RENDERINGS 11/21/2025 A-3.1 PROPOSED 3D RENDERINGS 11/21/2025 DRAWING LIST PROJECT DIRECTORY ABBREVIATIONS SYMBOLS LOCATION MAPGENERAL CONDITIONS N FIELD CONDITIONS: CONTRACTOR SHALL VERIFY ALL CONDITIONS, AS WELL AS ALL DIMENSIONS AND CONDITIONS INDICATED ON THE DRAWINGS, PRIOR TO ACTUAL CONSTRUCTION. ANY VARIATION FROM CONDITIONS INDICATED ON THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF OWNER PRIOR TO COMMENCING WORK. COORDINATION OF WORK: THE CHARACTER AND SCOPE OF WORK ARE ILLUSTRATED BY THE WORKING DRAWINGS. CONTRACTOR SHALL CAREFULLY EXAMINE ALL THE DRAWINGS AND SHALL BE RESPONSIBLE FOR THE PROPER INSTALLATION OF HIS WORK AND PROPER CONSIDERATION FOR THE WORK OF OTHERS AND EXISTING BUILDING CONSTRUCTION. DO NOT PLACE DUCTS, PIPING, CONDUIT, OR ANY OBSTRUCTION SO AS TO IMPAIR REQUIRED CEILING HEIGHT AND CLEARANCE FOR THE PROTECTION OF EXISTING ADJACENT SPACES AND BUILDING FACILITIES. BUILDING CODES AND REGULATIONS: ALL WORK SHALL CONFORM TO ALL GOVERNING CODES AND REGULATIONS. QUALITY STANDARDS: ALL SUCH WORK SHALL BE PERFORMED IN A FIRST CLASS WORKMANLIKE MANNER AND SHALL BE IN GOOD AND USABLE CONDITION AT THE DATE OF COMPLETION THEREOF. CONTRACTOR SHALL GUARANTEE ALL WORK PERFORMED TO BE FREE FROM ANY AND ALL DEFECTS IN WORKMANSHIP AND MATERIALS FOR ONE (1) YEAR FROM THE DATE OF ACCEPTANCE HAS BEEN CONFIRMED IN WRITING BY THE OWNER REPRESENTATIVE. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPLACEMENT OR REPAIR WITHOUT ANY ADDITIONAL CHARGE FOR ANY AND ALL WORK DONE

Page 1

THE DATE OF ACCEPTANCE HAS BEEN CONFIRMED IN WRITING BY THE OWNER REPRESENTATIVE. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPLACEMENT OR REPAIR WITHOUT ANY ADDITIONAL CHARGE FOR ANY AND ALL WORK DONE OR FURNISHED WHICH SHALL BECOME DEFECTIVE WITHIN THIS ONE (1) YEAR PERIOD. THE CORRECTION OF SUCH WORK SHALL INCLUDE, WITHOUT ADDITIONAL CHARGE, ALL EXPENSES AND DAMAGES IN CONNECTION WITH SUCH REMOVAL, REPLACEMENT, OR REPAIR OF ANY PART OF THE WORK WHICH MAY BE DAMAGED OR DISTURBED THEREBY. ALL WARRANTIES OR GUARANTEES AS TO MATERIALS OR WORKMANSHIP ON OR WITH RESPECT TO THE WORK SHALL BE SO WRITTEN THAT SUCH GUARANTEE OR WARRANTIES SHALL INSURE TO THE BENEFIT OF THE OWNER. RUBBER WHEEL CARTS: CONTRACTOR CARTS, EQUIPMENT BOXES, ETC. MUST BE EQUIPPED WITH RUBBER WHEELS. RUBBISH REMOVAL: CONTRACTOR SHALL KEEP PREMISES CLEAN EACH DAY AFTER WORK. ALL GARBAGE CREATED BY THE CONSTRUCTION SHALL BE RECYCLED AND TAKEN TO THE RESPECTIVE FACILITIES FOR RECYCLING. IF NOT POSSIBLE GC IS STILL RESPONSIBLE TO DISPOSE PROPERLY ALL DEBRIS AND GARBAGE FROM SITE. SUPPLEMENTARY CONDITIONS: DURING THE CONSTRUCTION PROCESS, THE CONTRACTOR SHALL BY MEANS OF BARRIERS, GUARDS, FIRE WATCHES, TARPAULINS AND/OR ANY OTHER PROTECTIVE DEVICES PROTECT: THE PUBLIC, AND ANY OTHER PERSON OR ITEM OF MATERIAL VALUE WHICH MAY BE SUBJECT TO DANGER OR DAMAGE IN ANY WAY AS RESULT OF THIS RENOVATION. GENERAL NOTES CL H.W. HOT WATER HR. HORIZ. HORIZONTAL HOUR STAINLESS STEEL VINYL COMPOSITION TILE ROUGH OPENING NUMBER PARTITION OVERHEAD ON CENTER PLASTIC LAMINATE PRECAST PRESSURE ROOM REQUIRED ROOF DRAIN RECEPTACLE REINFORCEMENT RAIN WATER LEADER STEEL SPECIFIED SIMILAR STANDARD STRUCTURAL TEMPERATURE SPECIFICATION SECTION TYPICAL VERTICAL VESTIBULE WATER CLOSET WELDED WIRE FABRIC TOP OF MASONRY TOP OF STEEL WOOD WITH WIRE GLASS TEMPERED PLYWOOD EXTERIOR INS. FINISHING SYS. HOLLOW METAL GYPSUM WALLBOARD GENERAL CONTRACTOR H.R. H.M. FDN. GA. G.C. G.W.B. GL. GALV. HANDRAIL GALVANIZED GAUGE GLASS FOUNDATION FIXT. FL. FOOT'G. FD. EXIST. E.I.F.S. FIXTURE FLOOR FLOOR DRAIN FOOTING EXISTING W.C. W.W.F. W/ WD. WG. TYP. VERT. VEST. V.C.T. TEMP. T.O.M. T.O.S. TEMP'D. STL. STD. STRUCT. CONTROL JOINT DRINKING FOUNTAIN E.F. EQUIP. ELEC. DN. D.F. EA. DWG. ELECTRIC EQUIPMENT EXHAUST

Page 1

ING EXISTING W.C. W.W.F. W/ WD. WG. TYP. VERT. VEST. V.C.T. TEMP. T.O.M. T.O.S. TEMP'D. STL. STD. STRUCT. CONTROL JOINT DRINKING FOUNTAIN E.F. EQUIP. ELEC. DN. D.F. EA. DWG. ELECTRIC EQUIPMENT EXHAUST FAN DRAWING EACH DOWN DIM. DBL. DEPT. CONC. C.J. CONT. DOUBLE DIMENSION DEPARTMENT CONCRETE CONTINUOUS SS R.O. SIM. SPEC. SPEC'D. SECT. REC. REINF. RM. R.D. REQ. R.W.L. P.C. PRESS. PLYWD. NO. O.H. PART. O.C. PL INDIVIDUAL INSULATION JOIST LAMINATE LAVATORY JOINT MACHINE MAXIMUM METAL MIRROR MODIFIED MINIMUM MECHANICAL MANUFACTURER MASONRY OPENING NOMINAL NOT IN CONTRACT NOT TO SCALECERAMIC TILE CONCRETE MASONRY UNIT CT C.O. COL. C.M.U. CLG. CEM. B.O. CLEAN OUT COLUMN BOTTOM OF CEILING CEMENT CENTER LINE BD. BLDG. ALT. A.B. ARCH. @ ALUM. BOARD BUILDING ALUMINUM ANCHOR BOLT ARCHITECT ALTERNATE AT MOD. NOM. N.T.S. N.I.C. MEP MAX. MTL. MIR. MIN. MECH. MACH. M.O. MFGR. JST. LAV. LAM. JT. ACOUSTICAL TILE AIR CONDITIONING ABOVE FINISHED FLOOR ABV. A.F.F. A/C A.C.T. ABOVE INSUL./INS. INDIV. EQ. EQUAL ELECTRICAL/PLUMBING MECHANICAL/ TOP OFT.O. PROJECT CODE ANALYSIS OCCUPANTOCC. ARCHITECT BERSA ARCHITECTS P.O.BOX 51 - NUTLEY NJ 07110 CONTACT: MARIA E. SARRIDO POSITION: PROJECT MANAGER PHONE: 973-901-6978 EMAIL: MARIAELENASARRIDO@BERSAARCHITECTS.COM OWNER ASHLAND PROPERTIES LLC CONTACT: ROLANDO CRIBEIRO PHONE: 201-442-9200 PHONF: ROLLYCPBUILDING@GMAIL.COM BUILDING DEPARTMENT TOWNSHIP OF WEST ORANGE 66 MAIN STREET - ROOM 217 WEST ORANGE, NJ 07052 CONTACT: TOM TRACEY CONSTRUCTION OFFICIAL PHONE: 973-325-4112 CIVIL ENGINEER GOLDEN & MORAN ENGINEERING 6 CAREY AVENUE BUTLER, NJ 07405 CONTACT: JOSEPH R. GOLDEN, PE, PP PHONE: 973-714-2131 EMAIL: GOLDENPE@GMAIL.COM 1SEAL NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED

Page 2

UP SPRINTER TYPE VAN 22'-24' LONG, TYP. REF. W UP UP FRONT STAIRWELL 100 (E) ELEVATOR CORRIDOR 011 MECHANICAL ROOM 017 DRY / TRIM ROOM 018 RECEIVING ROOM 019 DELIVERY ROOM 020 VAULT 015 PACKAGING 014 PROCESSING 012 MEN'S LOCKER RM 008 WOMEN'S LOCKER RM 007 CORRIDOR 005 OFFICE 006 SECURITY OFFICE 004 PACKAGING OVERFLOW CLOSET 016 SPRINKLER / ELEC. ROOM 002 SPRINKLER ROOM 003 ENTRY VESTIBULE 001 BREAK ROOM 009 (E) ELECTRICAL EQUIPMENT 24" x 96" WORKING TABLE 24" x 96" WORKING TABLE OSMOSIS SYSTEM CAN FILTER STORAGE 010 JANITOR'S CLOSET 013 REAR STAIRWELL 100a W/C 7'-11 1/2" 7'-9 1/4" 5'-5" 11'-0 3/4" 18'-2 1/4"10'-1" 16'-5 3/4" 15'-0" 24'-10 1/2" 21'-0 1/2" 15'-7" 9'-7 3/4" 24'-4 1/4" 29'-0 3/4" WATER TANK WATER TANK WATER TANK WATER TANK WATER TANK WATER TANK WATER TANK (E) TRANS- FORMER NOTE: REFER TO CIVIL DRAWINGS FOR PARKING SPACES AND SITE PLAN INFORMATION. UP TO HVAC PROPOSED FENCE TO CONCEAL EX. TRANSFORMER AND NEW GENERATOR. 1 A-2.0 1 A-2.1 2 A-2.1 2 A-2.0 PROPOSED FIXTURE PLAN: FIRST FLOOR A-1.0 REV# DISTRIBUTION DATE PLANNING BD. SUBMITTAL 04/30/2025 SEAL NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED REVIEWED BY: SHEET NO. DATE: DRAWN BY: PROJECT NO. SCALE: PROJECT LOCATION: SHEET TITLE: 17-2023 06/30/23 SHEET NO. MS GS AS NOTED CANNABIS CULTIVATION BUILDING RENOVATION 76 Ashland Avenue West Orange, NJ P.O. BOX #51 NUTLEY, NJ 07110 PH: 973-901-6976 WWW.BERSAARCHITECTS.COM CONSULTANTS COPYRIGHT 2023 1 ENGINEER AND PLANNER 11/21/2025 COMMENTS 3/16" = 1'-0" 1 PROPOSED FIXTURE PLAN: FIRST FLOOR LEGEND CANOPY AREA POST-HARVEST AREA MANUFACTURING AREA SUPPORT/ADMINISTRATIVE AREA CIRCULATION AREA FIRST FLOOR TOTAL GROSS AREA: 6,103 SQ FT 1SEAL NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED

Page 3

DN FLOWER ROOM 102 DN UP CORRIDOR 101 VEGGIE ROOM 105 FOYER / FRONT STAIRWELL 100 JANITOR'S CLOSET 104 REAR STAIRWELL 100a (E) ELEVATOR FLOWER ROOM 106 FLOWER ROOM 103 DN UP DN DN 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED CAN FILTER CO2 CO2 CO2 CAN FILTER 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 24" x 96" WORKING TABLE 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED CAN FILTER CO2 CO2CO2 24" x 96" WORKING TABLE SHELVING UNIT CAN FILTER 24" x 96" WORKING TABLE CAN FILTER CAN FILTER CO2 CO2 3'-4 1/4"1'-0" 1'-0" CO2 18'-0" 3'-9" 4'-3 1/2" 2'-0" 1'-0" 1'-0" 1'-3 1/2" 5'-11 1/4" SHELVING UNIT 9'-5 1/2" 1'-0" 4'-4 1/4" 5'-11 1/4" 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 48" BED 48" x 48" BED 48" x 48" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 4'-3 3/4" 24" x 96" WORKING TABLE CAN FILTER 1'-0" 2'-0" 1'-0"1'-0" 5'-3 3/4" CO2 CO2 CO2 SHELVING UNIT 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 1'-0" 1'-0" 1'-0"1'-0" 4'-6 1/2" 34'-7 3/4"18'-5" 42'-0" 41'-11 1/2"22'-0" 4'-6 1/4" CORRIDOR 101b CORRIDOR 101a WATER TANK WATER TANK HVAC UNIT ON CANOPY. EXACT NUMBER AND LOCATIONS TO BE DETERMINED BY MEP ENGINEER, TYPICAL. PROPOSED FENCE TO CONCEAL HVAC UNITS. DN 1 A-2.0 1 A-2.1 2 A-2.0 2 A-2.1 PROPOSED FIXTURE PLAN: SECOND FLOOR A-1.1 REV# DISTRIBUTION DATE PLANNING BD. SUBMITTAL 04/30/2025 SEAL NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED REVIEWED BY: SHEET NO. DATE: DRAWN BY: PROJECT NO. SCALE: PROJECT LOCATION: SHEET TITLE: 17-2023 06/30/23 SHEET NO. MS GS AS NOTED CANNABIS CULTIVATION BUILDING RENOVATION 76 Ashland Avenue West Orange, NJ P.O. BOX #51 NUTLEY, NJ 07110 PH: 973-901-6976 WWW.BERSAARCHITECTS.COM CONSULTANTS COPYRIGHT 2023 1 ENGINEER AND PLANNER 11/21/2025 COMMENTS 3/16" = 1'-0" 1 PROPOSED FIXTURE PLAN: SECOND

Page 3

st Orange, NJ P.O. BOX #51 NUTLEY, NJ 07110 PH: 973-901-6976 WWW.BERSAARCHITECTS.COM CONSULTANTS COPYRIGHT 2023 1 ENGINEER AND PLANNER 11/21/2025 COMMENTS 3/16" = 1'-0" 1 PROPOSED FIXTURE PLAN: SECOND FLOOR LEGEND CANOPY AREA POST-HARVEST AREA MANUFACTURING AREA SUPPORT/ADMINISTRATIVE AREA CIRCULATION AREA SECOND FLOOR TOTAL GROSS AREA: 7,081 SQ FT 1SEAL NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED

Page 4

DN (E) ELEVATOR FRONT STAIRWELL 100 FLOWER ROOM 202 FLOWER ROOM 203 VEGGIE ROOM 205 FLOWER ROOM 206 UNISEX ADA TOILET ROOM 207 24" x 96" WORKING TABLE 24" x 96" WORKING TABLE DN CAN FILTER CAN FILTER CO2 CO2 CAN FILTER CAN FILTER CO2 CO2 CO2 CAN FILTER JANITOR'S CLOSET 204 REAR STAIRWELL 100a 1'-0" 2'-0" 1'-0"1'-0" 5'-3 3/4" 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 1'-0" 48" x 96" BED 4'-0 1/4" 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 1'-0" 48" x 96" BED 48" x 48" BED 3'-3 3/4"1'-0" 1'-0" 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED CO2 18'-0" CO2 CO2 CO2 34'-7 3/4" 5'-11 1/4" 5'-0" 5'-0" 48" x 96" BED 48" x 96" BED 48" x 48" BED 4'-3 1/2" 2'-0" 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 1'-0" 1'-0" 42'-0" 1'-3 1/2" CAN FILTER CO2 CO2CO2 24" x 96" WORKING TABLE SHELVING UNIT CAN FILTER 5'-11 1/4" 22'-0" 41'-11 1/2" SHELVING UNIT SHELVING UNIT 9'-5 1/2" 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 1'-0" 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 4'-6 1/2" 48" x 96" BED 48" x 48" BED 48" x 48" BED 48" x 48" BED 48" x 48" BED 48" x 48" BED 1'-0" 48" x 96" BED 48" x 96" BED 48" x 48" BED 4'-4 1/4" CORRIDOR 201 CORRIDOR 201b CORRIDOR 201a WATER TANK WATER TANK 1 A-2.0 1 A-2.1 2 A-2.0 2 A-2.1 PROPOSED FIXTURE PLAN: THIRD FLOOR A-1.2 REV# DISTRIBUTION DATE PLANNING BD. SUBMITTAL 04/30/2025 SEAL NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED REVIEWED BY: SHEET NO. DATE: DRAWN BY: PROJECT NO. SCALE: PROJECT LOCATION: SHEET TITLE: 17-2023 06/30/23 SHEET NO. MS GS AS NOTED CANNABIS CULTIVATION BUILDING RENOVATION 76 Ashland Avenue West Orange, NJ P.O. BOX #51 NUTLEY, NJ 07110 PH: 973-901-6976 WWW.BERSAARCHITECTS.COM CONSULTANTS COPYRIGHT 2023 1 ENGINEER AND PLANNER 11/21/2025 COMMENTS 3/16" = 1'-0" 1 PROPOSED FIXTURE PLAN: THIRD FLOOR LEGEND CANOPY AREA POST-HARVEST AREA MANUFACTURING AREA SUPPORT/ADMINISTRATIVE AREA CIRCULATION AREA THIRD FLOOR TOTAL GROSS AREA:

Page 4

1/21/2025 COMMENTS 3/16" = 1'-0" 1 PROPOSED FIXTURE PLAN: THIRD FLOOR LEGEND CANOPY AREA POST-HARVEST AREA MANUFACTURING AREA SUPPORT/ADMINISTRATIVE AREA CIRCULATION AREA THIRD FLOOR TOTAL GROSS AREA: 5,616 SQ FTSEAL NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED

File revisions (1)