Page 3

DN FLOWER ROOM 102 DN UP CORRIDOR 101 VEGGIE ROOM 105 FOYER / FRONT STAIRWELL 100 JANITOR'S CLOSET 104 REAR STAIRWELL 100a (E) ELEVATOR FLOWER ROOM 106 FLOWER ROOM 103 DN UP DN DN 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED CAN FILTER CO2 CO2 CO2 CAN FILTER 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 24" x 96" WORKING TABLE 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED CAN FILTER CO2 CO2CO2 24" x 96" WORKING TABLE SHELVING UNIT CAN FILTER 24" x 96" WORKING TABLE CAN FILTER CAN FILTER CO2 CO2 3'-4 1/4"1'-0" 1'-0" CO2 18'-0" 3'-9" 4'-3 1/2" 2'-0" 1'-0" 1'-0" 1'-3 1/2" 5'-11 1/4" SHELVING UNIT 9'-5 1/2" 1'-0" 4'-4 1/4" 5'-11 1/4" 48" x 96" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 48" x 48" BED 48" x 48" BED 48" x 48" BED 48" x 48" BED 48" x 96" BED 48" x 96" BED 48" x 48" BED 4'-3 3/4" 24" x 96" WORKING TABLE CAN FILTER 1'-0" 2'-0" 1'-0"1'-0" 5'-3 3/4" CO2 CO2 CO2 SHELVING UNIT 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 48" x 96" BED 1'-0" 1'-0" 1'-0"1'-0" 4'-6 1/2" 34'-7 3/4"18'-5" 42'-0" 41'-11 1/2"22'-0" 4'-6 1/4" CORRIDOR 101b CORRIDOR 101a WATER TANK WATER TANK HVAC UNIT ON CANOPY. EXACT NUMBER AND LOCATIONS TO BE DETERMINED BY MEP ENGINEER, TYPICAL. PROPOSED FENCE TO CONCEAL HVAC UNITS. DN 1 A-2.0 1 A-2.1 2 A-2.0 2 A-2.1 PROPOSED FIXTURE PLAN: SECOND FLOOR A-1.1 REV# DISTRIBUTION DATE PLANNING BD. SUBMITTAL 04/30/2025 SEAL NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED REVIEWED BY: SHEET NO. DATE: DRAWN BY: PROJECT NO. SCALE: PROJECT LOCATION: SHEET TITLE: 17-2023 06/30/23 SHEET NO. MS GS AS NOTED CANNABIS CULTIVATION BUILDING RENOVATION 76 Ashland Avenue West Orange, NJ P.O. BOX #51 NUTLEY, NJ 07110 PH: 973-901-6976 WWW.BERSAARCHITECTS.COM CONSULTANTS COPYRIGHT 2023 1 ENGINEER AND PLANNER 11/21/2025 COMMENTS 3/16" = 1'-0" 1 PROPOSED FIXTURE PLAN: SECOND

Page 3

st Orange, NJ P.O. BOX #51 NUTLEY, NJ 07110 PH: 973-901-6976 WWW.BERSAARCHITECTS.COM CONSULTANTS COPYRIGHT 2023 1 ENGINEER AND PLANNER 11/21/2025 COMMENTS 3/16" = 1'-0" 1 PROPOSED FIXTURE PLAN: SECOND FLOOR LEGEND CANOPY AREA POST-HARVEST AREA MANUFACTURING AREA SUPPORT/ADMINISTRATIVE AREA CIRCULATION AREA SECOND FLOOR TOTAL GROSS AREA: 7,081 SQ FT 1SEAL NOT FOR CONSTRUCTION UNLESS SIGNED AND SEALED

File revisions (1)