THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © BOHLER UNITS GRAB TENSILE STRENGTH ASTM D-4632 265 LBS GRAB TENSILE ELONGATION ASTM D-4632 20% PUNCTURE ASTM D-4833 135 LBS MULLEN BURST ASTM D-3786 420 PSI TRAPEZOID TEAR ASTM D-4533 45 LBS UV RESISTANCE ASTM D-4355 90 % APPARENT OPENING SIZE ASTM D-4751 20 US SIEVE FLOW RATE ASTM D-4491 200 GAL/MIN/SQ FT PERMITTIVITY ASTM D-4491 1.5 SEC -1 TACK COAT PAVEMENT JOINT STORAGE BED (CLEAN, WASHED, OPEN GRADED AASHTO NO. 2 BROKEN STONE) (SEE NOTES) STANDARD PAVEMENT SECTION (SEE DETAILS) 1' TEST METHOD INSPECTION PORT (SEE NOTES) (SEE DETAIL) 2" CHOKER COURSE (CLEAN, WASHED, AASHTO NO. 57 BROKEN STONE) ±1.67' (SEE DRAINAGE PLAN) PROPERTIES 6" PERVIOUS ASPHALT SURFACE COURSE (SEE NOTE #1) 1. REMOVE TRAPPED SEDIMENT WHEN BRIGHTLY COLORED EXPANSION RESTRAINT CAN NO LONGER BE SEEN. 2. GEOTEXTILE SHALL BE A WOVEN POLYPROPYLENE FABRIC THAT MEETS OR EXCEEDS REQUIREMENTS IN THE SPECIFICATIONS TABLE. 3. PLACE AN OIL ADSORBENT PAD OR PILLOW OVER INLET GRATE WHEN OIL SPILLS ARE A CONCERN. 4. INSPECT PER REGULATORY REQUIREMENTS. 5. THE WIDTH, "W", OF THE FILTER SACK SHALL MATCH THE INSIDE WIDTH OF THE GRATED INLET BOX. 6. THE DEPTH, "D", OF THE FILTER SACK SHALL BE BETWEEN 24 INCHES AND 36 INCHES. 7. THE LENGTH, "L", OF THE FILTER SACK SHALL MATCH THE INSIDE LENGTH OF THE GRATED INLET BOX. 8. FOR INLET WITH CURB PIECE OPENING, THE CURB PIECE OPENING SHALL BE BLOCKED SO ALL STORMWATER RUNOFF WILL BE FILTERED THROUGH THE FILTER SACK. SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES TM SPECIFICATION TABLE 1' WRAP FILTER FABRIC ALONG SIDES AND BOTTOM 3" PERFORATED 6" PVC UNDERDRAIN @ 0.20% (SEE DRAINAGE PLAN) TOP OF STONE STORAGE: 367.65' BOTTOM OF STONE STORAGE: 366.65' 3" 366.65' REVISIONS 1' MIN. SEPARATION TO SHWT WIDTH VARIES (SEE DRAINAGE PLAN) FINISH GRADE GEOTEXTILE BAG DEPTH = D D 1/4 D 1/4" BRIGHTLY COLORED NYLON ROPE EXPANSION RESTRAINT LOOPS SIZED FOR 1" REBAR. USE REBAR FOR A HANDLE TO EMPTY FILTER SACK AT A SEDIMENT COLLECTION LOCATION. 1/2 D 1/4" BRIGHTLY

Page 13

DEPTH = D D 1/4 D 1/4" BRIGHTLY COLORED NYLON ROPE EXPANSION RESTRAINT LOOPS SIZED FOR 1" REBAR. USE REBAR FOR A HANDLE TO EMPTY FILTER SACK AT A SEDIMENT COLLECTION LOCATION. 1/2 D 1/4" BRIGHTLY COLORED NYLON ROPE EXPANSION RESTRAINT LE NG TH =L DT WI H= COMMENT 09/17/2025 DRAWN BY CHECKED BY REV. PER SCD COMMENTS. REV. PER TOWNSHIP 12/10/2025 COMMENTS TGH TXL AWS TXL NOTES: 1. PERMEABLE ASPHALT SURFACE COURSE TO HAVE 15-25% POROSITY. FOR PARKING AREAS, A POLYMER MODIFIED BINDER PG 64E-22 MUST BE USED. PERVIOUS PAVEMENT SURFACE COURSE TO HAVE MINIMUM TESTED INFILTRATION RATE OF 6.4 IN/HR (20 IN/HR IF USED FOR STORMWATER QUALITY CONTROL). REFER TO GEOTECHNICAL ENGINEERING/REPORT FOR THICKNESS. 2. REFER TO NJ SWBMP MANUAL CHAPTER 9.6 AND NJDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION FOR OPEN-GRADED FRICTION COURSE COMPOSITION, MIX DESIGN, & INSTALLATION TEMPERATURE SPECIFICATIONS. 3. STORAGE BED AGGREGATE MUST BE PLACED IN LOOSE LIFTS NOT TO EXCEED 6 INCHES AND COMPACTED USING PLATE COMPACTORS PER NJ SWBMP MANUAL. 4. AT LEAST ONE INSPECTION PORT, WITH A REMOVABLE CAP, MUST BE PROVIDED AT THE UPSTREAM AND DOWNSTREAM ENDS OF THE PERFORATED SECTION OF THE NETWORK OF PIPES WITH ITS LOCATION DENOTED IN THE MAINTENANCE PLAN. THE INSPECTION PORT MUST BE PLACED AT LEAST 3 FEET FROM ANY EDGE. ADDITIONALLY, EACH INSPECTION PORT MUST BE FLUSH WITH THE SURFACE OF THE SURFACE LAYER AND EXTEND DOWN TO THE UNDERDRAIN PIPE NETWORK. THE SIZE OF THE INSPECTION PORT MUST BE LARGE ENOUGH TO ALLOW FOR MAINTENANCE ACTIVITIES. 5. SEALANT, TOP COAT, AND OTHER TREATMENTS SHALL NOT BE USED ON THE PERVIOUS ASPHALT PAVEMENT COURSE. CONSTRUCTION MAY NOT TAKE PLACE DURING RAIN OR SNOW, NOR WHEN THE SUBSOIL IS FROZEN. 6. POST-CONSTRUCTION TESTING OF THE PERMEABLE ASPHALT SURFACE COURSE IS REQUIRED AND MUST CONFORM TO THE METHODS OF EITHER ASTM C1701: STANDARD TEST METHOD FOR INFILTRATION RATE OF IN-PLACE PERVIOUS CONCRETE OR ASTM C1781: STANDARD TEST METHOD FOR SURFACE INFILTRATION RATE OF PERMEABLE UNIT PAVEMENT SYSTEMS. AT LEAST THREE LOCATIONS MUST BE USED FOR THE TEST, AND THEY SHOULD BE SPACED EVENLY ACROSS THE PERVIOUS PAVING SYSTEM. FAILURE TO ACHIEVE THE MINIMUM DESIGN INFILTRATION RATE OF THE SURFACE COURSE AT ONE OR MORE LOCATION INDICATES THE SYSTEM CANNOT BE PUT IN SERVICE UNTIL THE SYSTEM IS CORRECTED TO YIELD ALL PASSING VALUES. UNLIKE THE

Page 13

E THE MINIMUM DESIGN INFILTRATION RATE OF THE SURFACE COURSE AT ONE OR MORE LOCATION INDICATES THE SYSTEM CANNOT BE PUT IN SERVICE UNTIL THE SYSTEM IS CORRECTED TO YIELD ALL PASSING VALUES. UNLIKE THE TEST METHODOLOGY OUTLINED IN THE ASTM STANDARDS, THE TEST RESULTS MUST NOT BE AVERAGED. INCLUDE A LOG FOR RECORDING EACH LOCATION AND ITS TEST RESULT FOR FUTURE REFERENCE IN THE MAINTENANCE PLAN. 7. PERVIOUS PAVEMENT AREA SHALL BE PROTECTED FROM SEDIMENT-LADEN RUNOFF DURING CONSTRUCTION TO AVOID REDUCED POROSITY. OVERFLOW HOLES 2"X2"X3/4" RUBBER BLOCK (TYP.) OR FLAT WASHERS 1 2 LOOPS SIZED FOR 1" REBAR. LIFT FILTER BAG FROM INLET USING REBAR FOR HANDLES OVERFLOW HOLES DATE SHWT ELEV: 363.00' INLET GRATE SECURE LIFTING LOOPS TO OR UNDER SURROUNDING SURFACE REV W Know what's below. Callbefore you dig. NEW JERSEY YOU MUST CALL 811 BEFORE ANY EXCAVATION WHETHER IT'S ON PRIVATE OR PUBLIC LAND. 1-800-272-1000 www.nj1-call.org SECTION VIEW PROFILE VIEW OF INSTALLED FILTER SACK ISOMETRIC VIEW ISSUED FOR MUNICIPAL & AGENCY REVIEW & APPROVAL INLET FILTER SACK 1 2 NOT TO SCALE BRICK RING TO SUPPORT CASTING, IF REQUIRED MANHOLE CASTING, CAMPBELL FOUNDRY PATTERN #1206A, OR APPROVED EQUIVALENT (NJ-O050301 - 04/2024) STANDARD FOR STORM SEWER INLET PROTECTION NOT TO SCALE 3 (Standards for Soil Erosion and Sediment Control in New Jersey - January 2014) PERVIOUS ASPHALT PAVEMENT WITH UNDERDRAIN NOT TO SCALE PROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: TYPE 'B' INLET WITH FRAME AND GRATE, CAMPBELL FOUNDRY PATTERN #2618, OR APPROVED EQUIVALENT PERVIOUS PAVEMENT (SEE DETAIL) 30" 8" MIN. REINFORCED CONCRETE LID (SEE NOTE #12) NJA230139.00-2A CRA / TGH TXL 08/14/2025 P-CIVL-CNDS PROJECT: PRELIMINARY & FINAL MAJOR SITE PLAN A MORTAR TO SLAB (TYP.) (NJ-S010103 - 01/2025) THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. 4' WIDE WEIR INV = 366.95' FOR 4' WIDE WEIR INV = 366.95' LADDER RUNGS 12" o.c. (TYP) PROPOSED RETAIL STORE 6" MIN CONCRETE WALL 15" HDPE (OUT) 12" MIN. 24" MAX. 365.43' (OUT) MAP: 87 | BLK: 157 | LOT: 5 457 MOUNT PLEASANT AVENUE TOWNSHIP OF WEST ORANGE ESSEX COUNTY, NEW JERSEY 365.60' (IN) 6" PVC (IN) TM BOHLER ENGINEERING NJ, LLC 4' 6" MIN. 3/4" CLEAN STONE UNDER CONCRETE (BY 4') 6" A 30 INDEPENDENCE BLVD.,

Page 13

NT AVENUE TOWNSHIP OF WEST ORANGE ESSEX COUNTY, NEW JERSEY 365.60' (IN) 6" PVC (IN) TM BOHLER ENGINEERING NJ, LLC 4' 6" MIN. 3/4" CLEAN STONE UNDER CONCRETE (BY 4') 6" A 30 INDEPENDENCE BLVD., SUITE 200 WARREN, NJ 07059 4' (BY 4') SECTION A-A Phone: Fax: (908) 668-8300 (908) 754-4401 www.BohlerEngineering.com NJ CERT. OF AUTHORIZATION NO. 24GA28400600 & MH000122 NOTES: 1. FOR INVERTS, PIPE SIZES AND ELEVATIONS, SEE PLANS. 2. THE CONCRETE STRUCTURE SHALL BE PRECAST CONCRETE TO MEET A MINIMUM OF H-25 LOADING. ALL UNITS SHALL BE CONSTRUCTED AND REINFORCED IN ACCORDANCE WITH THE APPROPRIATE ASTM, ACI, NJPDES, AND AASHTO STANDARDS. ALL PRECAST SECTIONS SHALL BE JOINED USING A GASKET AND CEMENT GROUT TO PRODUCE A "LEAK-PROOF" JOINT. 3. ALL STRUCTURAL CONCRETE TO BE NJDOT CLASS 'B', A/E. 4. THE INLET GRATE SHALL BE BICYCLE SAFE WITH A CURB PIECE OF TYPE "N-ECO". CONTRACTOR TO VERIFY WITH MUNICIPALITY THE TYPE OF ECO CURB PIECE AND GRATE TO BE USED. 5. THE INLET FRAME AND GRATE/COVER AND MANHOLE FRAME/RIM SHALL BE FABRICATED TO MEET A MINIMUM OF H-25 LOADING, UNLESS PRE-APPROVED IN WRITING BY THE ENGINEER, OR UNLESS NOTED ON THE INDIVIDUAL STRUCTURE NOTES. 6. ALL PIPES SHALL EXTEND NO MORE THAN 1 INCH INTO THE STRUCTURE. 7. A CONCRETE PIPE FLOW CHANNEL SHALL BE INSTALLED IN THE STRUCTURE BOTTOM, AFTER ALL THE PIPES ARE INSTALLED, OR THE FLOW CHANNELS CAN BE PRECAST WITH THE BASE. 8. STORM DRAIN INLET LABEL SHOULD READ "NO DUMPING, DRAINS TO WATERWAYS" OR OTHERWISE APPROVED BY THE ENGINEER. FISH LOGOS SHALL ALSO BE INCLUDED ON BOTH SIDES OF THE LABEL. 9. UNLESS INDICATED OTHERWISE ALL CONSTRUCTION TO COMPLY WITH DOT SPECIFICATIONS. 10. ROCK SCREEN SHALL BE STAINLESS STEEL WITH £ 1/2 INCH OPENINGS. 11. CONTRACTOR AND/OR PRECASTER TO PROVIDE SHOP DRAWINGS FOR REVIEW BY ENGINEER PRIOR TO FABRICATION. T. LAM PROFESSIONAL ENGINEER NEW JERSEY LICENSE No. 47863 NEW YORK LICENSE No. 092942 CONNECTICUT LICENSE No. 30024 PENNSYLVANIA LICENSE No. 76746 SHEET TITLE: SOIL EROSION & SEDIMENT CONTROL PLAN NOTES & DETAILS SHEET NUMBER: AS G:\2023\NJA230139.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA230139.00-2A----->LAYOUT: C-803 EROS Dec 15, 2025 CONCRETE FILL 4 C-803 OUTLET CONTROL STRUCTURE FOR PERVIOUS PAVEMENT NOT TO SCALE 5 (NJ-U010408 - 09/2023) HAY BALE SEDIMENT BARRIER NOT TO SCALE (SOURCE: THE STANDARDS FOR SOIL EROSION AND SEDIMENT

Page 13

RETE FILL 4 C-803 OUTLET CONTROL STRUCTURE FOR PERVIOUS PAVEMENT NOT TO SCALE 5 (NJ-U010408 - 09/2023) HAY BALE SEDIMENT BARRIER NOT TO SCALE (SOURCE: THE STANDARDS FOR SOIL EROSION AND SEDIMENT CONTROL IN NEW JERSEY, 7TH EDITION, JANUARY 2014, REVISED JULY 2017) REVISION 2 - 12/10/2025