Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Jan 7, 2026

12 Site Plans 12 10 2025

Preserved file SHA-2568a0d01bab4db3eab712e2cdc7188c48f6dd672d5fc77c498cb3c5bcfd951d7be

Indexed text · page 3

Show all pages
Page 3

MAXIMUM ME MATCH EXISTING MEP MECHANICAL, ELECTRICAL, AND PLUMBING MH MANHOLE AASHTO AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS AC ACRE / ACRES MIN MINIMUM AD AREA DRAIN MJ MECHANICAL JOINT ADA ACCESSIBLE / AMERICANS WITH DISABILITIES ACT MUTCD MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES AG ABOVE GROUND NOAA APPROX APPROXIMATE NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION ARCH ARCHITECTURAL NRCS NATIONAL RESOURCE CONSERVATION SERVICE ASPH ASPHALT O&M ASSF AREA SUBJECT TO STORMWATER FLOWAGE OPERATIONS AND MAINTENANCE OC ON CENTER OCS OUTLET CONTROL STRUCTURE ASSOC ASSOCIATION BC BOTTOM OF CURB BF BASEMENT FLOOR OGS OIL AND GRIT SEPARATOR BIO BIOGARDEN ORD ORDINANCE BIT BITUMINOUS PA / POA POINT OF ANALYSIS BK BLOCK PC POINT OF CURVATURE BL BASELINE PCCR POINT OF CURVATURE, CURB RETURN BLDG BUILDING PERF PERFORATED BM BENCH MARK PG PROPOSED GRADE BRL BUILDING RESTRICTION LINE PI POINT OF INTERSECTION STANDARD DRAWING LEGEND FOR ENTIRE PLAN SET LIMIT OF WORK LOW LOW LIMIT OF DISTURBANCE LOD LOD SAWCUT LINE TYPICAL NOTE TEXT ONSITE PROPERTY LINE / R.O.W. LINE NEIGHBORING PROPERTY LINE / INTERIOR PARCEL LINE EASEMENT LINE SETBACK LINE CURB AND GUTTER DEPRESSED CURB AND GUTTER POLE LIGHT POG POINT OF GRADE CB CATCH BASIN PP POLYPROPYLENE PIPE CF CUBIC FEET PROP PROPOSED CI CURB INLET PT POINT OF TANGENCY CIT CHANGE IN TYPE PTCR POINT OF TANGENCY, CURB RETURN CL CENTER LINE CMP CORRUGATED METAL PIPE PVI POINT OF VERTICAL INTERSECTION CO CLEAN OUT PVMT PAVEMENT ACORN LIGHT CONC CONCRETE PVT POINT OF VERTICAL TANGENCY TYPICAL SIGN CONN CONNECTION R RADIUS / RADII COORD COORDINATE R/W RIGHT-OF-WAY / RIGHTS-OF-WAY CY CUBIC YARD RCP REINFORCED CONCRETE PIPE DEC DECORATIVE RD ROOF DRAIN DEP DEPARTMENT OF ENVIRONMENTAL PROTECTION REGS REGULATIONS RELO TO BE RELOCATED DET DETENTION REQ REQUIRED DIA DIAMETER RET RETENTION DMH DRAINAGE MANHOLE RETAINING WALL DOM DOMESTIC RET WALL DOT DEPARTMENT OF TRANSPORTATION RETO TO BE RETURNED TO OWNER RG RAIN GARDEN DP DESIGN POINT S SLOPE DWL DASHED WHITE LINE SAN SANITARY SEWER SESC SOIL EROSION AND SEDIMENT CONTROL DYL DOUBLE YELLOW LINE EG EXISTING GRADE ELEC ELECTRIC SF SQUARE FEET ELEV ELEVATION SHLO STATE HIGHWAY

Page 3

DWL DASHED WHITE LINE SAN SANITARY SEWER SESC SOIL EROSION AND SEDIMENT CONTROL DYL DOUBLE YELLOW LINE EG EXISTING GRADE ELEC ELECTRIC SF SQUARE FEET ELEV ELEVATION SHLO STATE HIGHWAY LAYOUT EOR ENGINEER OF RECORD SMH SANITARY MANHOLE EP / EOP EDGE OF PAVEMENT STA STATION ES / EOS EDGE OF SHOULDER STM STORM WATER / STORM SEWER EW END WALL EX EXISTING FDC FIRE DEPARTMENT CONNECTION FEMA FEDERAL EMERGENCY MANAGEMENT AGENCY FES REVISIONS UTILITY POLE WITH LIGHT BORDERING VEGETATIVE WETLAND CORRUGATED PLASTIC PIPE TRANSITION CONCRETE CURB & GUTTER BVW CPP PROPOSED NOTE SPILL TRAFFIC LIGHT REV DATE 1 09/17/2025 2 COMMENT REV. PER SCD COMMENTS. REV. PER TOWNSHIP 12/10/2025 COMMENTS PARKING COUNTS X CONTOUR LINE 190 187 SPOT ELEVATIONS FF 517.00 TC 516.00 BC 515.55 SANITARY LABEL SAN-100 STORM LABEL A-100 SANITARY SEWER LATERAL SL UNDERGROUND WATER LINE W UNDERGROUND ELECTRIC LINE E UNDERGROUND GAS LINE G OVERHEAD WIRE OH Know what's below. ME 516.00 Callbefore you dig. NEW JERSEY YOU MUST CALL 811 BEFORE ANY EXCAVATION WHETHER IT'S ON PRIVATE OR PUBLIC LAND. 1-800-272-1000 www.nj1-call.org ISSUED FOR MUNICIPAL & AGENCY REVIEW & APPROVAL THIS DRAWING IS INTENDED FOR MUNICIPAL AND/OR AGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A CONSTRUCTION DOCUMENT UNLESS INDICATED OTHERWISE. PROJECT No.: DRAWN BY: CHECKED BY: DATE: CAD I.D.: SWPPP UNDERGROUND TELEPHONE LINE T TBA TO BE ABANDONED TO BE REMOVED UNDERGROUND CABLE LINE C TBR FLARED END SECTION TBV TO BE VACATED FF FINISH / FIRST FLOOR TC TOP OF CURB FFE FINISH / FIRST FLOOR ELEVATION Tc TIME OF CONCENTRATION TD TRENCH DRAIN FG FINISH GRADE FH FIRE HYDRANT FM PRELIMINARY & FINAL MAJOR SITE PLAN FOR STORM SEWER SANITARY SEWER MAIN S PROPOSED RETAIL STORE HYDRANT TPF TREE PROTECTION FENCE FO FIBER OPTIC TR TO REMAIN G GRADE TRANS TRANSITION GC GENERAL CONTRACTOR TYP TYPICAL GEO GEOTECH/GEOTECHNICAL UG UNDERGROUND GARAGE FLOOR ELEVATION (AT DOOR) UP UTILITY POLE GF / GFE USGS UNITED STATES GEOLOGICAL SURVEY NJA230139.00-2A CRA / TGH TXL 08/14/2025 P-CIVL-CNDS PROJECT: STORMWATER POLLUTION PREVENTION PLAN FORCE MAIN TGH TXL AWS TXL TYPICAL LIGHT SINGLE/SOLID WHITE LINE TELECOMMUNICATIONS / TELEDATA DRAWN BY CHECKED BY UTILITY POLE SWL TELE THE INFORMATION, DESIGN AND

Page 3

POLLUTION PREVENTION PLAN FORCE MAIN TGH TXL AWS TXL TYPICAL LIGHT SINGLE/SOLID WHITE LINE TELECOMMUNICATIONS / TELEDATA DRAWN BY CHECKED BY UTILITY POLE SWL TELE THE INFORMATION, DESIGN AND CONTENT OF THIS PLAN ARE PROPRIETARY AND SHALL NOT BE COPIED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION FROM BOHLER. ONLY APPROVED, SIGNED AND SEALED PLANS SHALL BE UTILIZED FOR CONSTRUCTION PURPOSES © BOHLER MAX SITE CIVIL AND CONSULTING ENGINEERING LAND SURVEYING PROGRAM MANAGEMENT LANDSCAPE ARCHITECTURE SUSTAINABLE DESIGN PERMITTING SERVICES TRANSPORTATION SERVICES LANDSCAPE AREA SANITARY MANHOLE S STORM MANHOLE D WATER METER WM MAP: 87 | BLK: 157 | LOT: 5 457 MOUNT PLEASANT AVENUE TOWNSHIP OF WEST ORANGE ESSEX COUNTY, NEW JERSEY WATER VALVE TM GFA GROSS FLOOR AREA GH GRADE HIGH (WALL) VERT VERTICAL GL GRADE LOW (WALL) VIF VERIFY IN FIELD GRT GRATE W WIDE / WIDTH GT GREASE TRAP W/L WATER LINE GV GATE VALVE WM WATER METER HDPE HIGH DENSITY POLYETHYLENE WQU WATER QUALITY UNIT HOR HORIZONTAL YD YARD DRAIN HP HIGH POINT # NUMBER HW HEADWALL #:# CURB INLET ICS INLET CONTROL STRUCTURE SLOPE EXPRESSED IN HORIZONTAL:VERTICAL IN FEET INF INFILTRATION ± PLUS OR MINUS CLEAN OUT C/O ELECTRIC MANHOLE E TELEPHONE MANHOLE T ELECTRIC BOX E ELECTRIC PEDESTAL EP GAS VALVE GV BOHLER ENGINEERING NJ, LLC INT INTERSECTION ° DEGREE INV INVERT Ø DIAMETER LF LINEAR FOOT ' FEET/FOOT LOC LIMIT OF CLEARING " INCHES LOD LIMIT OF DISTURBANCE LOS LINE OF SIGHT LOW LIMIT OF WORK LP LOW POINT LS LANDSCAPE GAS METER G 30 INDEPENDENCE BLVD., SUITE 200 WARREN, NJ 07059 Phone: Fax: TYPICAL END SECTION (908) 668-8300 (908) 754-4401 www.BohlerEngineering.com NJ CERT. OF AUTHORIZATION NO. 24GA28400600 & MH000122 HEADWALL OR ENDWALL GRATE INLET T. LAM PROFESSIONAL ENGINEER NEW JERSEY LICENSE No. 47863 NEW YORK LICENSE No. 092942 CONNECTICUT LICENSE No. 30024 PENNSYLVANIA LICENSE No. 76746 SHEET TITLE: GENERAL LEGEND MONITORING WELL SHEET NUMBER: TEST PIT T- # C-103 B- # REVISION 2 - 12/10/2025 BENCHMARK AS G:\2023\NJA230139.00\CAD\DRAWINGS\PLAN SETS\CIVIL SITE PLANS\P-CIVL-CNDS-NJA230139.00-2A----->LAYOUT: C-103 LGND Dec 15, 2025 FOR ENTIRE PLAN SET LSA TM STANDARD ABBREVIATIONS BORING

File revisions (1)