Supporting Documentation · Apr 15, 2026
Stormwater Maintenance Plan and Field Manual 01282026 4932 5213 7869 v2
bc3227325e2a072065ec4da098edcd6d27fbc6b4de03e8bc12ffd18efd741a91Indexed text · page 21
Show all pagesPART V - Inspection Checklist / Maintenance Actions Checklist (circle one): Quarterly / Annual / Monthly / Special Event Inspection Checklist No. ______________ Inspection Date: _______________ Preventative Maintenance Date of most recent rain event: __________ Frequency Circle One Quarterly Annual Rain Event Rain Condition (circle one): Drizzle / Shower / Downpour / Other _____________ Ground Condition (circle one): Dry / Moist / Ponding / Submerged / Snow accumulation For Inspector For Maintenance Crew Component No. Component Name Inspection Item and Inspection Item No. Inspected Preventative / Corrective Maintenance Actions Comments Storm Sewer Collection system 1 Structures broken or in disrepair, sediment, water present after 72 hours. Y__ N__ 2 Sediment and standing water observed after 72 hours. Y__ N__ 3 Excessive sediment or debris present in the inspection port Y__ N__ . 4 Little or no flow into the system Y__ N__
File revisions (1)
- Sep 29, 2026
bc3227325e2a525,831 bytes