Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Apr 15, 2026

Stormwater Management Report Revised as of 01282026 4936 0314 8685 v2

Preserved file SHA-256f6777d506bee83c79ba913bab178b45234e55066fd88f20823a02a45d6fdf50b

Indexed text · page 127

Show all pages
Page 127

24-223 DRAINAGE DESIGN-PROPOSED-UPDATE NOAA 24-hr D 2-Year-2020 Rainfall=3.47", P2=3.47" Prepared by Jarmel Kizel Architects & Engnrs Printed 1/28/2026 HydroCAD® 10.20-6a s/n 12607 © 2024 HydroCAD Software Solutions LLC Page 5 Summary for Subcatchment 1S: Roof Runoff = 2.04 cfs @ 12.01 hrs, Volume= 13,091 cf, Depth= 3.24" Routed to Link 11L : Proposed Disturbed Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-36.00 hrs, dt= 0.50 hrs NOAA 24-hr D 2-Year-2020 Rainfall=3.47", P2=3.47" Area (sf) CN Description * 48,537 98 Roof and Amenity Area 48,537 100.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 0.7 53 0.0200 1.26 Sheet Flow, ROOF Smooth surfaces n= 0.011 P2= 3.47" 0.5 196 0.0200 6.95 5.46 Pipe Channel, 12 ROOF DRAIN 12.0" Round Area= 0.8 sf Perim= 3.1' r= 0.25' n= 0.012 0.3 217 0.0424 11.74 14.41 Pipe Channel, 15 15.0" Round Area= 1.2 sf Perim= 3.9' r= 0.31' n= 0.012 1.5 466 Total