Stormwater Management Report Revised as of 01282026 4936 0314 8685 v2

Preserved file SHA-256f6777d506bee83c79ba913bab178b45234e55066fd88f20823a02a45d6fdf50b

Indexed text · page 14

Show all pages
Page 14

24-223 DRAINAGE DESIGN-EXISTING-UPDATE NOAA 24-hr D 2-Year-2020 Rainfall=3.47", P2=3.47" Prepared by Jarmel Kizel Architects & Engnrs Printed 1/28/2026 HydroCAD® 10.20-6a s/n 12607 © 2024 HydroCAD Software Solutions LLC Page 5 Summary for Subcatchment E1A: E1A DISTURBED/IMPERVIOUS Runoff = 2.94 cfs @ 12.01 hrs, Volume= 18,871 cf, Depth= 3.24" Routed to Link 8L : EXISTING DISTURBED Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-36.00 hrs, dt= 0.50 hrs NOAA 24-hr D 2-Year-2020 Rainfall=3.47", P2=3.47" Area (sf) CN Description 69,966 98 Paved parking, HSG C 69,966 100.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 0.7 100 0.0650 2.30 Sheet Flow, Parking lot Smooth surfaces n= 0.011 P2= 3.47" 1.4 343 0.0420 4.16 Shallow Concentrated Flow, Parking lot Paved Kv= 20.3 fps 2.1 443 Total