Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Apr 15, 2026

Stormwater Management Report 03302026

Preserved file SHA-256f21e274dca0e46b0f772672884e856d0c7ea7056c08892da2245c124f65038dd

Indexed text · page 135

Show all pages
Page 135

24-223 DRAINAGE DESIGN-PROPOSED-2026-03-30 NOAA 24-hr D 2-Year-2020 Rainfall=3.47", P2=3.47" Prepared by Jarmel Kizel Architects & Engnrs Printed 3/30/2026 HydroCAD® 10.20-6a s/n 12607 © 2024 HydroCAD Software Solutions LLC Page 23 Summary for Link P-DP 1: PROP DP 1 Inflow Area = 115,774 sf, 57.23% Impervious, Inflow Depth = 2.29" for 2-Year-2020 event Inflow = 3.22 cfs @ 12.04 hrs, Volume= 22,126 cf Primary = 3.22 cfs @ 12.04 hrs, Volume= 22,126 cf, Atten= 0%, Lag= 0.0 min Routed to Link 15L : TOTAL PROPOSED Primary outflow = Inflow, Time Span= 0.00-30.00 hrs, dt= 0.50 hrs Link P-DP 1: PROP DP 1 Hydrograph Inflow 3.22 cfs Primary 3.22 cfs Inflow Area=115,774 sf 3 Flow (cfs) 2 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Time (hours)