Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Apr 15, 2026

Stormwater Management Report 03302026

Preserved file SHA-256f21e274dca0e46b0f772672884e856d0c7ea7056c08892da2245c124f65038dd

Indexed text · page 175

Show all pages
Page 175

24-223 DRAINAGE DESIGN-PROPOSED-2026-03-30 NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" Prepared by Jarmel Kizel Architects & Engnrs Printed 3/30/2026 HydroCAD® 10.20-6a s/n 12607 © 2024 HydroCAD Software Solutions LLC Page 63 Summary for Subcatchment P3C: P3C- Roof Area Runoff = 0.51 cfs @ 12.00 hrs, Volume= 3,352 cf, Depth= 8.94" Routed to Link P-DP 2 : PROP DP 2 Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-30.00 hrs, dt= 0.50 hrs NOAA 24-hr D 100-Year-2020 Rainfall=9.18", P2=3.47" Area (sf) CN Description * 4,500 98 Roof and Amenity Area 4,500 100.00% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 0.9 52 0.0100 0.95 Sheet Flow, ROOF Smooth surfaces n= 0.011 P2= 3.47" 0.2 54 0.0216 5.51 1.92 Pipe Channel, 8 ROOF DRAIN 8.0" Round Area= 0.3 sf Perim= 2.1' r= 0.17' n= 0.012 1.1 106 Total