Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Apr 15, 2026

Stormwater Management Report 03302026

Preserved file SHA-256f21e274dca0e46b0f772672884e856d0c7ea7056c08892da2245c124f65038dd

Indexed text · page 243

Show all pages
Page 243

24-223 DRAINAGE DESIGN-PROPOSED-2026-03-30 NOAA 24-hr D 100-Year-2050 Rainfall=11.52", P2=4.09" Prepared by Jarmel Kizel Architects & Engnrs Printed 3/30/2026 HydroCAD® 10.20-6a s/n 12607 © 2024 HydroCAD Software Solutions LLC Page 131 Summary for Link 11L: Proposed Disturbed Inflow Area = 69,715 sf, 92.28% Impervious, Inflow Depth = 11.04" for 100-Year-2050 event Inflow = 9.67 cfs @ 12.01 hrs, Volume= 64,128 cf Primary = 9.67 cfs @ 12.01 hrs, Volume= 64,128 cf, Atten= 0%, Lag= 0.0 min Routed to Link P-DP 1 : PROP DP 1 Primary outflow = Inflow, Time Span= 0.00-30.00 hrs, dt= 0.50 hrs Link 11L: Proposed Disturbed Hydrograph Inflow 9.67 cfs Primary 10 9.67 cfs Inflow Area=69,715 sf 9 8 7 Flow (cfs) 6 5 4 3 2 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Time (hours)