Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Jun 3, 2026

29906 15 Ridgeway West Orange 5 26 26 HydroCAD Report

Preserved file SHA-2560dbe5051e9b6f9baf08b57f0fcaaa8bfdb9783769b948c3ddb275cb66b13a08d

Indexed text · page 25

Show all pages
Page 25

29906 15 Ridgeway West Orange Sec NOAA 24-hr D 10-Year-2020 Rainfall=5.38", P2=3.47" Prepared by Ensurplan Inc Printed 5/26/2026 HydroCAD® 10.20-8a s/n 11646 © 2025 HydroCAD Software Solutions LLC Page 8 Summary for Subcatchment 12S: PERMEABLE PAVEMENT TO THE INFILTRATION Runoff = 1.51 cfs @ 12.09 hrs, Volume= 0.100 af, Depth= 3.93" Routed to Pond 12P : Front Yard Basin Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-36.00 hrs, dt= 0.01 hrs NOAA 24-hr D 10-Year-2020 Rainfall=5.38", P2=3.47" Area (sf) CN Description * 6,776 99 Permeable Pavement 6,514 74 >75% Grass cover, Good, HSG C 13,290 87 Weighted Average 6,514 49.01% Pervious Area 6,776 50.99% Impervious Area Tc Length Slope Velocity Capacity Description (min) (feet) (ft/ft) (ft/sec) (cfs) 0.4 220 0.0340 9.63 5.25 Pipe Channel, 10.0" Round Area= 0.5 sf Perim= 2.6' r= 0.21' n= 0.010 PVC, smooth interior Subcatchment 12S: PERMEABLE PAVEMENT TO THE INFILTRATION Hydrograph Runoff 1.51 cfs NOAA 24-hr D 10-Year-2020 Rainfall=5.38" P2=3.47" Runoff Area=13,290 sf 1

Page 25

Runoff Area=13,290 sf 1 Runoff Volume=0.100 af Flow (cfs) Runoff Depth=3.93" Flow Length=220' Slope=0.0340 '/' Tc=0.4 min CN=87 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Time (hours)

File revisions (1)