Supporting Documentation · Sep 17, 2026
13 Porter Rd Application package rcd 6 2 2026
b4fb2ab8971ca51dca8b803c89b071e202c26a8d53966cbdd2771199000a4563Indexed text
ARCHITECT OF RECORD: FC3 ARCHITECTURE+DESIGN, LLC NJ CERT. OF AUTHORIZ. #AC-58100 STRUCTURAL NOTE: 1. DO ALL NECESSARY CUTTING, BLOCKING, SHORING AND TEMPORARY SUPPORT OF ALL EXSITING FLOOR JOISTS, CEILING JOISTS AND ROOF CONSTRUCTION AS REQUIRED, PRIOR TO THE REMOVAL OF ANY LOAD-
BEARING WALLS OR BEAMS. FRANK CUNHA III, AIA, NCARB REGISTERED ARCHITECT NEW JERSEY #16411 BATHROOM NOTES (TYPICAL): FC3 PROJECT NO. 26-NJ-XXX 6 1. PROVIDE SOLID BLOCKING FOR THE INSTALLATION OF ALL MEDICINE BACKYARD AREA CABINETS, TOWEL RACKS, GRAB BARS, ACCESSORIES, ETC.
CABINETS, TOWEL RACKS, GRAB BARS, ACCESSORIES, ETC. 2. ALL PLUMBING FIXTURES TO BE SELECTED BY OWNER AND INSTALLED BY GENERAL CONTRACTOR OR PLUMBER. 3. INSTALL MARBLE OR CERAMIC TILE FLOOR SELECTED BY OWNER, OVER THIN SET WITH 4" HIGH, COVED TILE BASE. 4. INSTALL MARBLE OR CERAMIC TILE, SELECTED BY OWNER, ON WALLS OF SHOWER AREA IN BATHROOM, AS DIRECTED BY OWNER, PROVIDE SHAMPOO NICHE IN WALL WHERE DIRECTED
SHAMPOO NICHE IN WALL WHERE DIRECTED BY OWNER. (OPTIONAL MARBLE OR CERAMIC TILE ON DROPPED CEILING ABOVE SHOWER, TO BE DETERMINED). ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE NOTE TO ELECTRICAL CONTRACTOR:
NOTE TO ELECTRICAL CONTRACTOR: ARCHITECT. THE REPRODUCTION INSTALL HEATED FLOOR PAD OVER OF THIS DRAWING FOR THE PLYWOOD SUB-FLOORING. EGRESS WINDOW NOTE: PURPOSE OF COPYING THIS WORK OR REVISING SAID DRAWING SHALL BE CONSIDERED A VIOLATION OF BOTH THE
BOTH THE PROFESSIONAL CODE OF ETHICS AND A THEFT OF COMPANY 2x6 STUD WALLS 1. CONTRACTOR SHALL VERIFY MIN. EGRESS WINDOW REQUIREMENTS ARE ASSETS, BOTH OF WHICH SHALL BE W/ R-19 BATT PROSECUTED TO THE FULLEST MET FOR EACH SLEEPING ROOM AND CONTACT ARCHITECT IMMEDIATELY IF EXTENT OF THE LAW AND CURRENT INSUL. VINYL STATUTES.
STATUTES. 2 SIDING (COLOR MINIMUM REQUREMENTS ARE NOT MET. 5 A-202 BY OWNER) TYP. 2. REFER TO 2021 INTERNATIONAL RESIDENTIAL CODE, NEW JERSEY Ed., Consultant: Aaron Gonzales, PhD 14'-7 1/2" 22'-5" SECTION R310-EMERGENCY ESCAPE AND RESCUE OPENINGS. GUTTER & LEADER 6'-0" 3'-6" 1'-5 1/2" 2'-3" 2'-3" 6'-6 1/2" SEE ELEVATIONS A. R310.2.1 MINIMUM OPENING AREA: SOAKING EMERGENCY ESCAPE AND RESUCE OPENINGS SHALL HAVE A NET
EMERGENCY ESCAPE AND RESUCE OPENINGS SHALL HAVE A NET TUB 42"x42" D.H. 24x24 D.H. CLEAR OPENING OF NOT LESS THAT 5.7 SQUARE FEET. THE NET CLEAR OPEING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND 2'-7 1/2" LINEN RESCUE OPEING FROM THE INSIDE. THE NET CLEAR HEIGHT OF THE OPEING SHALL BE NOT LESS THAT 24 INCHES AND THE NET CLEAR OUTDOOR 2x6 STUD WALLS
2x6 STUD WALLS W/ R-19 BATT WIDTH SHALL BE NOT LESS THAT 20 INCHES. PAVED AREA BATH 24x80 9'-2 1/2" OPENING EXISTING NO CHANGES W.I.C. INSUL. VINYL 8'-6" POCKET 30x80 (NO CHANGES) TILE WOOD SIDING (COLOR B. R310.2.2
TILE WOOD SIDING (COLOR B. R310.2.2 WINDOW SILL HEIGHT: BY OWNER) TYP. 1 WHERE A WINDOW IS PROVIDED AS THE EMERGENCY ESCAPE AND 6'-0" FAN A-202 RESCUE OPENING, IT SHALL HAVE A SILL HEIGHT OF NOT MORE THAT REV. # KITCHEN 44 INCHES ABOVE THE FLOOR; WHERE THE SILL HEGITH IS BELOW 32x80 GRADE, IT SHALL BE PROVIDED WITH A WINDOW WELL IN
File revisions (1)
- Sep 29, 2026
b4fb2ab8971c19,301,938 bytes