SMOOTH PARGE FINISH. REV. # SITS ON A 2'x1' CONT. CONC. 4'-6"
FOOTING (MIN. 3500PSI) W/ (2) #4 REBAR HORIZ. 8'-8" BELOW GRADE. 5" CONC. SLAB (MIN. 3500 PSI)
IN. 3500 PSI) W/ 6x6 WWF EXISTING 8' x 7' GARAGE DOOR FIN. FLR. SELECTED BY OWNER BASEMENT -8'-3" 1'-0" 4
1'-0" 4 2'-0" 4" DIA. PERF. PVC FOUNDATION DRAIN TO WATER
DISPOSAL SYSTEM. W/ CRUSHED STONE N BASEMENT CROSS SECTION LARGER THAN PIPE
PERFORATION. ALL PERIMETER 3 OF NEW BASEMENT 3/8" = 1'-0" BASEMENT FLOOR PLAN 1 1/4" = 1'-0"
WEST ORANGE , NJ 07072 8d @ 6" O.C. DOUBLE ROW LEGEND METAL FLASHING CEILING PROVIDE 2 LAYERS OF 5/8" GYPSUM TYPE "X" FOR INR. FIRE RECESSED LIGHTING AS SELECTED BY WOOD FRAME 10"X7" 1/2" EXT. GRADE SHEATHING TYP. SEPERATION AS PER UL L544 (above) OWNER
OWNER 1 Hour-Rated construcrtion Dimensional Lumber 2" SPOT LIGHTING AS SELECTED BY ROUGH OPENING 7" LEAVE 1/8" GAP @ construction detail Description Test Number OWNER PROTECTED TOP LAP
ENDS & EDGES. (TYP.) - Two Layers 5/8" Sheetrock Firecode Care GA-FC-5406 Gypsum panels. AND E/F EXHAUST FAN W/LIGHT TO BE BLOCK 175.24, LOT 3 NAIL FLASHING 11"
11" - 2 x 10 Wood Joist 24" o.c. RC-2601 SELECTED BY OWNER TO ROOF 8d @ 6" O.C. @ PANEL EDGES 'TYVEK' HOUSE WRAP - Face layers Joints Finished RHODE RESIDENCE 3