13 Porter Site Plan Updated rcd 9 1 2026

Preserved file SHA-256a7ea227b5d4555256863aac631ac21a39f36c64ef9e9ecd06a4ffba16a6cc40d

Indexed text

Page 2

DESIGN FLOOD ELEVATION EL. 9.0' AIR INTAKE AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. 5. FOOTING DEPTH SHALL BE MIN 42" BELOW FINISHED GRADE ELEVATION AND SHALL BEAR ON VIRGIN AND/OR DRYER EXHAUST DUCTS SHALL BE CONSTRUCTED OF 4" MIN DIA 28 GA METAL WITH SMOOTH INTERIOR FINISH COMPACTED SOIL COMPACTED TO 98% AND 95% RESPECTIVELY. 3. INFORMATION CONCERNING BASE FLOOD ELEVATIONS (BFE IS BASED UPON 6. UNLESS OTHERWISE NOTED IN THE DRAWINGS, ALL STRUCTURAL (LUMBER) WOOD MEMBERS SHALL BE AND 35 FT MAX LENGTH. FEMA'S PRELIMINARY FLOOD INSURANCE RATE MAPS. THE BFE IS 8'-0" 7. U.O.N. KITCHEN RANGE HOOD EXHAUST SHALL BE CONSTRUCTED OF GALV STEEL, ST STL OR COPPER AIR TIGHT DOUGLAS FIR NORTH GRADE #2. WOOD FRAMING MEMBERS SHALL HAVE A MINIMUM FIBER STRESS OF Fb = 1,200 4. EXISTING AND PROPOSED GRADE ELEVATIONS AND BUILDING FLOOR PSI AND MIN MODULUS OF ELASTICITY E=1,400,000 PSI AND WITH SMOOTH INTERIOR SURFACE ELEVATIONS ARE BASE UPON A PLOT PLAN PREPARED BY ALL DRAWINGS AND WRITTEN 8. PIPING CARRYING HEATING OR COOLING FLUIDS SHALL BE INSULATED WITH MIN R-3 THERMAL INSULATION

Page 2

ALL DRAWINGS AND WRITTEN 8. PIPING CARRYING HEATING OR COOLING FLUIDS SHALL BE INSULATED WITH MIN R-3 THERMAL INSULATION 7. DOUBLE FLOOR JOISTS WHERE PARTITIONS RUN PARALLEL WITH FLOOR JOISTS. INSTALL (2) 2X10 HEADERS MATERIALS APPEARING HEREIN CONSTITUTE ORIGINAL AND PAUL SCHLOSSBACH, PLS ABOVE OPENINGS U.O.N. DOUBLE FLOOR JOISTS UNDER BATH TUBS. ALL JOISTS AND HEADERS SHALL BEAR 4" UNPUBLISHED WORK OF THE 9. WHERE INFILTRATION RATE OF A DWELLING UNIT IS LESS THAN 5 AIR CHANGES PER HOUR, WHOLE-HOUSE 5. ACCORDING TO FEMA FIRM, THE HOUSE IS LOCATED IN ZONE 'AE-8' ARCHITECT. THE REPRODUCTION MECHANICAL VENTILATION SYSTEM SHALL BE DESIGNED/PROVIDED BY OTHERS AND EQUIPPED WITH CONTROLS MIN. U.O.N. OF THIS DRAWING FOR THE 6. THE VOLUME BETWEEN THE SLAB ON GRADE AND THE UNDERSIDE OF THE 8. ACHIEVE MINIMUM THERMAL INSULATION REQUIREMENTS IN ACCORDANCE WITH ENERGY COMPLIANCE

Page 2

E SLAB ON GRADE AND THE UNDERSIDE OF THE 8. ACHIEVE MINIMUM THERMAL INSULATION REQUIREMENTS IN ACCORDANCE WITH ENERGY COMPLIANCE PURPOSE OF COPYING THIS WORK ACCORDING TO APPLICABLE CODES STRUCTURE SHALL NOT BE A HABITABLE SPACE. IT SHALL ONLY BE USED OR REVISING SAID DRAWING SHALL BE CONSIDERED A VIOLATION OF CERTIFICATE (REFER TO SHEET G101.1). BOTH THE PROFESSIONAL CODE OF FOR STORAGE. 9. WOOD CLOSER THAN 8" TO FINISHED GRADE, AT WOOD DECKS AND IN DIRECT CONTACT WITH CONCRETE OR ETHICS AND A THEFT OF COMPANY

Page 2

WOOD CLOSER THAN 8" TO FINISHED GRADE, AT WOOD DECKS AND IN DIRECT CONTACT WITH CONCRETE OR ETHICS AND A THEFT OF COMPANY 7. THE FOUNDATION HAS BEEN DESIGNED IN ACCORDANCE WITH: GROUND SHALL BE TREATED. WOOD JOISTS CLOSER THAN 18" AND WOOD GIRDERS CLOSER THAN 12" TO ASSETS, BOTH OF WHICH SHALL BE PROSECUTED TO THE FULLEST PLUMBING NOTES A. THE UNIFORM CONSTRUCTION CODE OF THE STATE OF NEW JERSEY BUILDING SUBCODE, INTERNATIONAL BUILDING CODE 2021 NEW JERSEY EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED PERIMETER OF BUILDING FOUNDATION SHALL BE TREATED. PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING AT ALL AREAS SURROUNDING THE BUILDING

Page 2

TREATED. PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING AT ALL AREAS SURROUNDING THE BUILDING EXTENT OF THE LAW AND CURRENT STATUTES. Consultant: Aaron Gonzales, PhD 5 EDITION. U.O.N. GARAGE SLAB TO BE SLOPED TOWARDS ENTRANCE AT 1:50 RATIO. 1. PLUMBING EQUIPMENT AND COMBUSTION DUCTS AND VENTING SHALL BE INSTALLED IN ACCORDANCE WITH B. AMERICAN SOCIETY OF CIVIL ENGINEERS, STANDARD SEI/ASCE 7-10 10. RISER HEIGHT SHALL BE 8" MAX AND TREAD SHALL BE 9" MIN FOR ANY INTERIOR OR EXTERIOR STEPS. THE APPLICABLE CODES, ALL GOVERNING RULES AND REGULATIONS AND MANUFACTURER'S INSTALLATION 'MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES'. GREATEST RISER HEIGHT OR TREAD DEPTH SHALL NOT EXCEED THE SMALLEST ONE BY MORE THAN 3/8". EVERY INSTRUCTIONS.

Page 2

RES'. GREATEST RISER HEIGHT OR TREAD DEPTH SHALL NOT EXCEED THE SMALLEST ONE BY MORE THAN 3/8". EVERY INSTRUCTIONS. C. AMERICAN SOCIETY OF CIVIL ENGINEERS, STANDARD SEI/ASCE 24-14 STAIR LANDING SHALL HAVE 36" MIN IN DIRECTION OF TRAVEL EXCEPT WHERE STAIRWAY HAVING NOT MORE 2. INDOOR COMBUSTION AIR OPENINGS SHALL HAVE A FREE AREA OF 100 SQ INCH MIN AND 1 SQ INCH PER 1,000 'FLOOD RESISTANT DESIGN AND CONSTRUCTION'. THAN (2) RISERS IS LOCATED ON THE EXTERIOR SIDE OF DOOR AND DOOR DOES NOT SWING OVER STAIRWAY. BTU/H MIN. PROVIDE (2) OPENINGS MIN, ONE LOCATED 12" AFF AND ONE LOCATED 12" BELOW THE BOTTOM OF D. FEDERAL EMERGENCY MANAGEMENT AGENCY. STANDARD FEMA P-55, MIN CLEAR HEADROOM OF 6'-8" SHALL BE PROVIDED AT ALL PARTS OF THE STAIRWAY. EXTERIOR LANDING ROOM CEILING. U.O.N. FREE AREA OF LOUVERS AND GRILLS SHALL BE 25% MAX FOR WOOD LOUVERS AND 75% 'COASTAL CONSTRUCTION MANUAL', AUGUST 2011. SLOPE IS 1:50 MAX WHERE REQUIRED. FOR METAL LOUVERS. 11. ALL SPECIFIED WINDOWS ARE ANDERSEN 400 UNLESS OTHERWISE REQUESTED BY THE OWNER. FINISH AS SPECIFIED BY THE OWNER. PROVIDE SNAP-IN GRILLS, END SCREENS AND JAMB EXTENSIONS WHERE REQUIRED. DESIGN LOADS ALL WINDOWS TO BE VINYL CLAD SOLID WOOD AND SHALL BE EQUIPPED WITH HIGH PERFORMANCE

Page 2

DESIGN LOADS ALL WINDOWS TO BE VINYL CLAD SOLID WOOD AND SHALL BE EQUIPPED WITH HIGH PERFORMANCE INSULATING GLASS. ELECTRICAL NOTES FLOOR DEAD LOAD: 10 LBS/SF INTERIOR PARTITION DEAD LOAD: 10 LBS/SF 12. EMERGENCY ESCAPE WINDOW OPENINGS SHALL HAVE 5.7 SF MIN. CLEAR OPENING WIDTH SHALL BE 20" MIN AND CLEAR HEIGHT SHALL BE 24" MIN. EMERGENCY ESCAPE WINDOW SILL HEIGHT SHALL BE 44" MAX. WINDOWS ROOF DEAD LOAD: 10 LBS/SF WITH SILLS LOCATED LESS THAN 24" AFF AND MORE THAN 72" ABOVE FINISHED GRADE SHALL BE PROTECTED REV. # 1. COMPLETE ELECTRICAL WIRING DIAGRAM SHALL BE IN ACCORDANCE WITH THE LATEST NATIONAL ELECTRICAL BEDROOM LIVE LOAD: 30 LBS/SF WITH A CODE COMPLIANT WINDOW FALL PREVENTION DEVICE CODE AND ANY APPLICABLE STATE AND LOCAL REGULATIONS. ROOMS OTHER THAN BEDROOMS LIVE LOAD: 40 LBS/SF 13.

Page 2

ODE AND ANY APPLICABLE STATE AND LOCAL REGULATIONS. ROOMS OTHER THAN BEDROOMS LIVE LOAD: 40 LBS/SF 13. SAFETY GLAZING REQUIREMENTS: 2. ELECTRICAL LAYOUT IS SHOWN DIAGRAMMATICALLY ONLY AND SHALL MEET ALL REQUIRED CLEARANCES AND GROUND SNOW LOAD: 30 LBS/SF - WHERE LOCATED IN FIXED AND OPERABLE DOORS PANELS AND IN GLAZING ADJACENT TO DOORS WITHIN 24" DISTANCES. CONTRACTOR TO REVIEW AND VERIFY LOCATION OF ALL FIXTURES AND DEVICES ROOM BY ROOM OR ON A WALL PERPENDICULAR TO THE PLANE OF DOOR IN A CLOSED POSITION WITHIN 24" OF THE HINGE SIDE WITH THE OWNER BEFORE AND AFTER WIRING IS COMPLETE. SOIL BEARING CAPACITY: 2000 PSF OF IN-SWINGING DOORS AND WHERE EXPOSED EDGE OF GLAZING IS LESS THAN 60" ABOVE WALKING SURFACE 3. PRIOR TO COMMENCEMENT OF WORK CONTRACTOR SHALL EITHER PROVIDE AN ALLOWANCE FOR GOOD - WINDOWS WHERE ALL CONDITIONS ARE MET: INDIVIDUAL PANELS EXCEED 9 SF, BOTTOM EDGE OF GLAZING IS 4 QUALITY UL LISTED LIGHT FIXTURES, DEVICES AND EQUIPMENT OR IDENTIFY AND COORDINATE THOSE TO BE COMPRESSIVE STRENGTH: LESS THAN 18" AFF, TOP OF GLAZING IS MORE THAN 36" AFF, ONE OR MORE WALKING SURFACES ARE LOCATED PURCHASED DIRECTLY BY THE OWNER. CONTRACTOR SHALL PROVIDE CATALOG CUTS OF PROPOSED SPREAD AND WALL FOOTING - 3,000 PSI WITHIN 36" MEASURED HORIZONTALLY FIXTURES. TOPPING SLAB - 3,000 PSI

Page 2

FIXTURES. TOPPING SLAB - 3,000 PSI - GUARDS AND RAILINGS 4. PRIOR TO COMMENCEMENT OF WORK CONTRACTOR TO VERIFY EXISTING ELECTRICAL PANEL CAPACITY AND SLAB ON GRADE - 4,000 PSI - WALLS AND ENCLOSURES WITH HOT TUBS, SPAS, STEAM ROOMS AND SHOWERS WHERE EXPOSED EDGE OF IDENTIFY REQUIRED UPGRADES TO BE INCLUDED IN WORK. GLAZING FACING WATER IS LESS THAN 60" AFF OR ORIENTED AT ANY ANGLE WITHIN HORIZONTAL DISTANCE OF 5. INSTALL TAMPER RESISTANT OUTLETS THROUGHOUT AND GROUND FAULT CIRCUIT INTERRUPTERS (GFCI OR SNOW: LESS THAN 60" FROM EDGE OF WATER GFI) BREAKERS OR RECEPTACLES IN BATHROOMS, KITCHENS, GARAGES, OUTDOORS AND IN ALL OTHER - Ground Snow, Pg=25 psf - ADJACENT TO STAIRS AND RAMPS WHERE BOTTOM EDGE OF GLAZING LOCATED LESS THAN 36" FROM THE LOCATIONS WHERE REQUIRED BY CODE. - Flat Roof, Pf=20 psf PLANE OF WALKING SURFACE OR LANDING BETWEEN STAIR FLIGHTS; GLAZING AT LANDINGS WITHIN 60" FROM 6. ALL 15 A OR 20 A, 120 V BRANCH CIRCUITS IN DWELLING UNITS SUPPLYING BEDROOMS, SUNROOMS, REC - Sloped Roof, Ps=20 psf THE FACE OF THE BOTTOM STAIR RISER ROOMS, CLOSETS, HALLWAYS OR SIMILAR ROOMS OR AREAS MUST BE PROTECTED BY ARC FAULT CIRCUIT 14. MINIMUM CEILING

Page 2

ALLWAYS OR SIMILAR ROOMS OR AREAS MUST BE PROTECTED BY ARC FAULT CIRCUIT 14. MINIMUM CEILING HEIGHT IN HABITABLE SPACES AND HALLWAYS SHALL BE 7'-0" MIN. BATHROOMS, TOILET INTERRUPTER. WIND: ROOMS AND LAUNDRY ROOMS SHALL HAVE A 6'-8" MIN CEILING HEIGHT. 7. MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH EFFICACY - Wind Speed, V=120 mph 15. INSTALL AIR & MOISTURE BARRIER AT THE OUTER FACE OF THE EXTERIOR GRADE SHEATHING. INSTALL SELF ADHERED JAMB FLASHING AND SEALANT AT ALL WINDOWS, DOORS AND ROOF PENETRATIONS. FLASH AND WEST ORANGE , NJ 07072 LAMPS. - Bldg Class, II 8. INSTALL AIR TIGHT LINE AND LOW VOLTAGE OUTLETS BOXES OR AIR BARRIER BEHIND ALL BOXES AT ALL - Exposure, BI WEAVE ALL ROOF VALLEYS. EXTERIOR WALLS AROUND BUILDING PERIMETER. - MWFRS Wind Pressure, p=15.0 psf 16. INSTALL FIREBLOCKING BETWEEN FLOORS, IN CONCEALED SPACES OF WALLS,