Supporting Documentation · Nov 4, 2026
1250703StormWaterManagementReport
4e86752994919d2ad538759355ec7513a754f9a434014a4961715ee00ebacd89Indexed text
CASEY & KELLER, INC. LAND SURVEYORS + CIVIL ENGINEERS + PLANNERS N.J. STATE BOARD OF PROFESSIONAL ENGINEERS & LAND SURVEYORS CERTIFICATE OF AUTHORIZATION NO. 24GA27985400 258 MAIN STREET, MILLBURN, NEW JERSEY, 07041 VOICE: 973-379-3280 FAX: 973-379-7993 STORM WATER MANAGEMENT REPORT 27 FAIRWAY DRIVE TOWNSHIP OF WEST ORANGE ESSEX COUNTY, NJ Block 86.01—Lot 6 PROJECT # 1250703 DATE: October 20, 2026 ______________________________________________________ MICHAEL LANZAFAMA, P.E. & P.L.S. NJ REG. # GB 30084
STORM WATER MANAGEMENT REPORT SUMMARY PROJECT LOCATION The subject property is located at 27 Fairway Drive, in the Township of West Orange, Essex County, New Jersey. It is identified as Lot 6 in Block 86.01 on the current Tax Maps of the Township and is situated within the R-5 Residential Zone. EXISTING CONDITIONS The site is presently developed with a two-story single-family dwelling and an attached garage. The property is also presently developed with a pool, patio, and various impervious walkways. The property has a total area of 23,982 square feet (0.551 acres). The property is planned to be subdivided into 3 lots. All essential utilities, including water, gas, electric, sanitary sewer, and cable, are provided via underground pipelines and conduits. The surrounding area is developed with residential uses. The property is not located within a floodplain, and no freshwater wetlands have been identified on or adjacent to the site. TOPOGRAPHY The topography of the site exhibits one consistent pattern. The site slopes from the west to the east. Ground elevations range from a high point of approximately 109 feet at the western property line to a low point of approximately 85 feet at the eastern property line. SOILS The site contains one type. The Soil Survey of Essex County has identified the site having a soil type as Boonton-Urban Land, Boonton Substratum complex, red sandstone lowland, 0 to 8 percent slopes. The Natural Resources Conservation Service has classified these soils as being in Hydrologic Soil Group “C”. A soil log and percolation test were conducted by Casey and Keller, Inc. and the results of these tests have been included within this report. IMPERVIOUS COVERAGE SUMMARY BUILDING(S) DRIVEWAY(S) WALKS/STEPS PATIO/DECK POOL MISC. TOTAL NET COVERAGE EXISTING (LOT 6.01) 0 0 143 1866 582 0 2591 IMPERVIOUS COVERAGE PROPOSED EXISTING PROPOSED (LOT 6.01) (LOT 6.02) (LOT 6.02) 1988 2309 2140 756 2315 1142 115 315 180 110 505 302 0 0 0 25 0 0 2994 403 5444 3764 EXISTING (LOT 6.03) 0 133 0 0 0 0 PROPOSED (LOT 6.03) 1467 608 95 210 0 25 133 2405 -1680 2272 1
STORMWATER MANAGEMENT Stormwater management is a critical component of the development process, requiring careful coordination between the site designer’s objectives, municipal ordinances, and the regulatory standards established by the New Jersey Department of Environmental Protection (see Hydrology section below). While best practices emphasize minimizing the use of structural stormwater controls, practical site constraints typically necessitate a balanced approach that incorporates both non-structural and structural measures. The existing site is already developed, with building coverage and paved surfaces. In accordance with the Township of West Orange requires that stormwater analyses be performed for the 2-year, 10-year, 25-year, and 100-year storm events. The reduction factors applied to the 2-, 10-, and 100-year storm events are 50%, 25%, and 20%, respectively. Although this project does not meet the requirements for a major development, these reductions were applied to further enhance the site performance. The “Natural Resources Conservation Service Method,” as outlined in Technical Release 55 (TR-55), was utilized to size and route stormwater through the proposed perforated pipe system. Stormwater hydrographs for both existing and proposed site conditions have been prepared and are included in this report to demonstrate compliance. Site Discharge The following table shows that the site would produce post-developed runoff rates and volumes that are lower than the site’s existing rates of runoff. The existing and proposed peak runoff rates (Q) from the site are summarized as follows: Summary Peak Detention Flow Lot 6.01 After Frequency 2 - 2020 10 - 2020 25 - 2020 100 - 2020 2 - 2050 10 - 2050 25 - 2050 100 - 2050 Disturbed Q 0.10 0.19 0.25 0.37 0.13 0.23 0.32 0.49 Reduction x x x x x x x x 0.50 0.25 0.00 0.20 0.50 0.25 0.00 0.20 = = = = = = = = Reduction Q 0.05 0.14 0.25 0.30 0.07 0.17 0.32 0.39 Q Non Disturb + + + + + + + + 0.02 0.04 0.05 0.08 0.03 0.05 0.07 0.11 Summary Peak Detention Flow Lot 6.03 After Frequency 2 - 2020 10 - 2020 25 - 2020 100 - 2020 2 - 2050 10 - 2050 25 - 2050 100 -
Non Disturb + + + + + + + + 0.02 0.04 0.05 0.08 0.03 0.05 0.07 0.11 Summary Peak Detention Flow Lot 6.03 After Frequency 2 - 2020 10 - 2020 25 - 2020 100 - 2020 2 - 2050 10 - 2050 25 - 2050 100 - 2050 Disturbed Q 0.04 0.09 0.13 0.20 0.05 0.12 0.17 0.27 Reduction x x x x x x x x 0.50 0.25 0.00 0.20 0.50 0.25 0.00 0.20 = = = = = = = = Reduction Q 0.02 0.07 0.13 0.16 0.03 0.09 0.17 0.22 = = = = = = = = Q Non Disturb + + + + + + + + 0.05 0.12 0.18 0.28 0.08 0.16 0.24 0.38 = = = = = = = = Q Total Q Allowable Proposed 0.07 0.18 0.30 0.38 0.10 0.22 0.39 0.50 0.05 0.12 0.18 0.28 0.08 0.16 0.23 0.38 Q Total Q Allowable Proposed 0.07 0.19 0.31 0.44 0.11 0.25 0.41 0.60 0.07 0.16 0.23 0.36 0.10 0.21 0.30 0.49 2
The Site Discharge table shows that the proposed project would result in post-developed runoff rates that are less than or equal to the site’s existing runoff rates. The hydrographs for the 2-year, 10-year, 25-year, and 100-year storms do not exceed at any time the predeveloped hydrographs for the same events as required per West Orange’s ordinance. Based upon this analysis, it is our professional opinion that the proposed storm water management system would enhance the existing downstream conveyance systems and meet the required Municipal standards. Calculations supporting these findings constitute the remainder of this report. 3
SOILS
563500 563510 563520 563530 563540 563550 563560 563570 563580 40° 46' 58'' N 4514860 4514860 4514870 4514870 4514880 4514880 4514890 4514890 4514900 4514900 4514910 4514910 4514920 4514920 563490 40° 46' 58'' N 74° 14' 46'' W 74° 14' 51'' W Soil Map—Essex County, New Jersey (27 Fairway Drive West Orange, NJ) Soil Map may not be valid at this scale. 40° 46' 55'' N 40° 46' 55'' N 563500 563510 563520 563530 563540 Map Scale: 1:487 if printed on A landscape (11" x 8.5") sheet. N 0 5 10 20 563550 563560 563570 563580 74° 14' 46'' W 74° 14' 51'' W 563490 Meters 30 Feet 0 20 40 80 120 Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 18N WGS84 Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 9/2/2026 7 Page 1 of 3
Soil Map—Essex County, New Jersey (27 Fairway Drive West Orange, NJ) MAP LEGEND Area of Interest (AOI) Area of Interest (AOI) Soils Soil Map Unit Polygons Soil Map Unit Lines Soil Map Unit Points Special Point Features Blowout Borrow Pit Clay Spot Closed Depression Gravel Pit Gravelly Spot Landfill Lava Flow Marsh or swamp MAP INFORMATION Spoil Area Stony Spot The soil surveys that comprise your AOI were mapped at 1:12,000. Very Stony Spot Warning: Soil Map may not be valid at this scale. Wet Spot Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Other Special Line Features Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography Mine or Quarry Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Essex County, New Jersey Survey Area Data: Version 21, Aug 28, 2025 Miscellaneous Water Perennial Water Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Rock Outcrop Date(s) aerial images were photographed: 16, 2022 Saline Spot Sandy Spot Oct 10, 2022—Oct The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Severely Eroded Spot Sinkhole Slide or Slip Sodic Spot Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 9/2/2026 8 Page 2 of 3
Soil Map—Essex County, New Jersey 27 Fairway Drive West Orange, NJ Map Unit Legend Map Unit Symbol BowrB Map Unit Name Acres in AOI Boonton - Urban land, Boonton substratum complex, red sandstone lowland, 0 to 8 percent slopes Totals for Area of Interest Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey Percent of AOI 0.5 100.0% 0.5 100.0% 9/2/2026 Page 3 of 3 9
Casey & Keller, Inc. LAND surveyors + civil engineers + PLANNERS N.J. STATE BOARD OF PROFESSIONAL ENGINEERS & LAND SURVEYORS CERTIFICATE OF AUTHORIZATION NO. 24GA27985400 258 Main Street, Millburn, NEW JERSEY, 07041 voice: 973-379-3280 fax: 973-379-7993 Address Test Pit No. Soil Type 27 Fairway Drive, West Orange Season Height Water Table Water Table Present 1 C N/A N/A Color Horizon Depth 89.0± (Topsoil) Texture Mottles Moist Value Chroma Abundance Size Contrast 0"-24" Borown 7.5 YR 4/2 N/A N/A N/A 24"-84" Yellowish Red 5 YR 4/6 N/A N/A N/A 84"-144" Yellowish Red 5 YR 4/6 N/A N/A N/A DEPTH TO STANDING WATER = "@ AM Loamy Clay Sandy Loamy Clay (Slate) Sandy Loamy Clay % Coarse Fragments Gravel/ Cobble/ Stone 9/25/2026 Date: Recorded By Structure Consistence Dry Moist TF Roots Boundary Wet 0/0/0 Granular Dry Common Clear 10/5/0 Granular Dry None Clear 0/75/0 Blocky Dry None Clear "@ AM DEPTH OF SEEPAGE = DEPTH OF LEDGEROCK = 11
File revisions (1)
- Oct 30, 2026
4e86752994915,215,319 bytes