Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Nov 4, 2026

1250703StormWaterManagementReport

Preserved file SHA-2564e86752994919d2ad538759355ec7513a754f9a434014a4961715ee00ebacd89

Indexed text · page 160

Show all pages
Page 160

27 Fairway Drive, West Orange NOAA 24-hr D 25-Year-2050 Rainfall=8.08", P2=4.09" 1250703-6.03 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 56 Time span=0.00-72.00 hrs, dt=1.00 hrs, 73 points Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Subcatchment 1S: Existing (Disturbed) Runoff Area=3,459 sf 0.00% Impervious Runoff Depth=5.00" Flow Length=75' Tc=3.9 min CN=74/0 Runoff=0.17 cfs 0.033 af Runoff Area=4,819 sf 0.00% Impervious Runoff Depth=5.00" Flow Length=75' Tc=3.9 min CN=74/0 Runoff=0.24 cfs 0.046 af Subcatchment 2S: Existing (Undisturbed) Subcatchment 3S: Propsed Runoff Area=2,157 sf 99.35% Impervious Runoff Depth=7.82" Flow Length=75' Tc=3.9 min CN=74/98 Runoff=0.15 cfs 0.032 af Subcatchment 4S: Bypass Runoff Area=6,121 sf 2.40% Impervious Runoff Depth=5.07" Flow Length=75' Tc=3.9 min CN=74/98 Runoff=0.30 cfs 0.059 af Pond 9P: Drywell Link 10L: Proposed Peak Elev=81.85' Storage=395 cf Inflow=0.15 cfs 0.032 af Discarded=0.04 cfs 0.033 af Primary=0.00 cfs 0.000 af Outflow=0.04 cfs 0.033 af Inflow=0.30 cfs 0.059 af Primary=0.30 cfs 0.059 af Total Runoff Area = 0.380 ac Runoff Volume = 0.171 af Average Runoff Depth = 5.39" 86.17% Pervious = 0.328 ac 13.83% Impervious = 0.053 ac 159

File revisions (1)