Town CrierWest Orange, New Jersey
← Back to search

Supporting Documentation · Nov 4, 2026

1250703StormWaterManagementReport

Preserved file SHA-2564e86752994919d2ad538759355ec7513a754f9a434014a4961715ee00ebacd89

Indexed text · page 162

Show all pages
Page 162

27 Fairway Drive, West Orange NOAA 24-hr D 25-Year-2050 Rainfall=8.08", P2=4.09" 1250703-6.03 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 58 Summary for Subcatchment 2S: Existing (Undisturbed) Runoff = 0.24 cfs @ 12.05 hrs, Volume= 0.046 af, Depth= 5.00" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 1.00 NOAA 24-hr D 25-Year-2050 Rainfall=8.08", P2=4.09" Area (sf) 4,819 4,819 CN 74 74 Description >75% Grass cover, Good, HSG C 100.00% Pervious Area Tc Length Slope (min) (feet) (ft/ft) 0.9 21 0.2800 Velocity (ft/sec) 0.40 1.9 39 0.1270 0.33 1.1 15 0.0790 0.23 3.9 75 Total Capacity (cfs) Description Sheet Flow, 1 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 2 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 3 Grass: Short n= 0.150 P2= 4.09" Subcatchment 2S: Existing (Undisturbed) Flow (cfs) Hydrograph 0.26 0.25 0.24 0.23 0.22 0.21 0.2 0.19 0.18 0.17 0.16 0.15 0.14 0.13 0.12 0.11 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 Runoff 0.24 cfs NOAA 24-hr D 25-Year-2050 Rainfall=8.08" P2=4.09" Runoff Area=4,819 sf Runoff Volume=0.046 af Runoff Depth=5.00" Flow Length=75' Tc=3.9 min CN=74/0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 161