Show all pages27 Fairway Drive, West Orange Water Quality Storm Water Quality Rainfall=1.25", P2=3.47" 1250703-6.03 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 77 Summary for Subcatchment 3S: Propsed Runoff = 0.04 cfs @ 1.00 hrs, Volume= Routed to Pond 9P : Drywell 0.004 af, Depth= 1.03" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 1.00 Water Quality Storm Water Quality Rainfall=1.25", P2=3.47" * * Area (sf) 1,467 608 68 14 2,157 14 2,143 CN 98 98 98 74 98 74 98 Description Roofs, HSG C Driveway, HSG C Front Walk, HSG C >75% Grass cover, Good, HSG C Weighted Average 0.65% Pervious Area 99.35% Impervious Area Tc Length Slope (min) (feet) (ft/ft) 0.9 21 0.2800 Velocity (ft/sec) 0.37 2.1 39 0.1270 0.31 1.2 15 0.0790 0.21 4.2 75 Total Capacity (cfs) Description Sheet Flow, 1 Grass: Short n= 0.150 P2= 3.47" Sheet Flow, 2 Grass: Short n= 0.150 P2= 3.47" Sheet Flow, 3 Grass: Short n= 0.150 P2= 3.47" 180