Supporting Documentation · Nov 4, 2026
1250703StormWaterManagementReport
4e86752994919d2ad538759355ec7513a754f9a434014a4961715ee00ebacd89Indexed text · page 71
Show all pages27 Fairway Drive, West Orange NOAA 24-hr D 10-Year-2050 Rainfall=6.37", P2=4.09" 1250703-6.01 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 52 Summary for Subcatchment 4S: Bypass Runoff = 0.16 cfs @ 12.07 hrs, Volume= Routed to Link 10L : Proposed 0.032 af, Depth= 3.50" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 1.00 NOAA 24-hr D 10-Year-2050 Rainfall=6.37", P2=4.09" Area (sf) 4,824 4,824 CN 74 74 Description >75% Grass cover, Good, HSG C 100.00% Pervious Area Tc Length Slope (min) (feet) (ft/ft) 0.9 21 0.2520 Velocity (ft/sec) 0.39 1.9 22 0.0450 0.20 2.1 31 0.0650 0.24 4.9 74 Total Capacity (cfs) Description Sheet Flow, 1 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 2 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 3 Grass: Short n= 0.150 P2= 4.09" Subcatchment 4S: Bypass Hydrograph 0.18 NOAA 24-hr D 10-Year-2050 Rainfall=6.37" P2=4.09" Runoff Area=4,824 sf Runoff Volume=0.032 af Runoff Depth=3.50" Flow Length=74' Tc=4.9 min CN=74/0 0.16 0.15 0.14 0.13 0.12 Flow (cfs) Runoff 0.16 cfs 0.17 0.11 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours) 70
File revisions (1)
- Oct 30, 2026
4e86752994915,215,319 bytes