Supporting Documentation · Nov 4, 2026
1250703StormWaterManagementReport
4e86752994919d2ad538759355ec7513a754f9a434014a4961715ee00ebacd89Indexed text · page 87
Show all pages27 Fairway Drive, West Orange NOAA 24-hr D 100-Year-2050 Rainfall=11.52", P2=4.09" 1250703-6.01 Prepared by Casey & Keller, Inc HydroCAD® 10.20-9a s/n 03272 © 2026 HydroCAD Software Solutions LLC Printed 10/21/2026 Page 68 Summary for Subcatchment 3S: Proposed Runoff = 0.23 cfs @ 12.01 hrs, Volume= Routed to Pond 9P : Drywell 0.051 af, Depth=11.25" Runoff by SCS TR-20 method, UH=SCS, Split Pervious/Imperv. UI as Pervious, Time Span= 0.00-72.00 hrs, dt= 1.00 NOAA 24-hr D 100-Year-2050 Rainfall=11.52", P2=4.09" * * Area (sf) 22 85 1,988 280 2,375 22 2,353 CN 74 98 98 98 98 74 98 Description >75% Grass cover, Good, HSG C Walk, HSG C Roofs, HSG B Driveway, HSG C Weighted Average 0.93% Pervious Area 99.07% Impervious Area Tc Length Slope (min) (feet) (ft/ft) 0.9 21 0.2520 Velocity (ft/sec) 0.39 1.9 22 0.0450 0.20 2.1 31 0.0650 0.24 4.9 74 Total Capacity (cfs) Description Sheet Flow, 1 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 2 Grass: Short n= 0.150 P2= 4.09" Sheet Flow, 3 Grass: Short n= 0.150 P2= 4.09" 86