10 improvements and that those materials had been reviewed by the Township. He reiterated that his role was to respond to questions concerning civil engineering and site design rather than repeat the traffic engineer's testimony. - Dr. Butensky asked for clarification on how the proposed driveway of approximately 8% grade couldn’t be dangerous during winter conditions. Mr. Cote explained that an 8% grade is acceptable under applicable standards and that certain standards could permit grades of up to 12%. - Mr. Paul Tractenberg of 96 Sullivan Drive, referred to a March 17, 2026 letter from Mr. Schkolnick to the Planning Board Secretary and the Planning Board. He stated that the letter identified several items for which the applicant was seeking relief from Township ordinance requirements governing the R2 zone. - Mr. Tractenberg first questioned the proposed retaining wall height, noting that the ordinance permits a maximum height of 4 feet while the applicant proposes a retaining wall approximately 21.5 feet high, more than five times the permitted height. He asked Mr. Cote to explain the justification for such a substantial deviation. Mr. Cote explained that the proposed retaining wall is located in conjunction with the stormwater management basin required to attenuate runoff from the site. He stated that the wall height is necessary to accommodate the stormwater management infrastructure while maintaining reasonable grades in the upper parking lot. - Mr. Tractenberg next questioned the minimum setback from the top of steep slopes having grades between 10% and 30%. He stated that the ordinance requires a 50-foot setback while the applicant proposes a 10-foot setback. He asked whether this reduction would create any safety concerns. Mr. Cote stated that he did not believe the proposed setback would create a safety issue. He explained that the design was intended to minimize disturbance to the property and avoid removing additional trees. He stated that providing the full setback would require further tree removal and that the applicant had been directed to minimize impacts on existing trees while providing replacement plantings for disturbed areas. - Mr. Tractenberg also questioned the applicant's request for a site plan waiver concerning tree removal on slopes of 10% or greater. He stated that the application proposes removing 191 trees located on slopes of

Page 10

berg also questioned the applicant's request for a site plan waiver concerning tree removal on slopes of 10% or greater. He stated that the application proposes removing 191 trees located on slopes of 10% or greater. Mr. Cote confirmed that the number was accurate. - Mr. Tractenberg asked whether Mr. Cote believed that the proposed tree removal was justified. Mr. Cote stated that the removals were associated with the positioning of the proposed improvements, the need to connect the site improvements to existing grades, and the installation of drainage structures necessary to mitigate stormwater runoff and improve drainage along Eagle Rock Avenue. He explained that the affected portions of the property are located near Eagle Rock Avenue and within areas having slopes of 10% or greater. - Mr. Tractenberg next questioned the minimum setback from the top of steep slopes exceeding 30%. He stated that the ordinance requires a 100-foot setback while the applicant proposes a 10-foot setback. Mr. Cote confirmed that the proposed reduction was justified for the same reasons previously discussed, including minimizing disturbance and accommodating the proposed infrastructure and site improvements. - Mr. Tractenberg questioned whether all of the requested ordinance deviations were being sought to add parking spaces and reconfigure the exit from a private country club. He referred to 36 additional parking spaces and stated that the existing parking lot was already hundreds of spaces short of the ordinance requirement. Mr. Cote confirmed that the requested deviations were associated with the parking and driveway improvements

File revisions (1)