Supporting Documentation · Nov 4, 2026
9 2 26 WO PB Draft Minutes
e517e0133e501772133e3ec02fd3a94ed8399b86900e5b5caa6858d51f060903Indexed text · page 24
Show all pages24 location and topography. Mr. Moronski explained that the design attempted to strike a balance between providing parking at the existing upper elevation and addressing drainage requirements. - Mayor McCartney then referred to the steep slope variance comments on the same page of the review report and asked the Board's planners and engineers whether the testimony had adequately justified the need for the requested steep slope variances. Ms. Apte stated that she had a follow-up question for Mr. Moronski concerning the steep slope testimony. - Ms. Apte asked whether every effort had been made in the site plan design to minimize the area of steep slope disturbance. She specifically asked whether alternative designs had been considered and whether the proposed layout represented the least impactful option with the fewest necessary steep slope variances. Ms. Apte stated that Mr. Moronski's response would also help address Mayor McCartney's question. Mr. Moronski stated that the design was intended to minimize the area of disturbance, particularly the disturbance and removal of existing trees. - Mr. Moronski explained that using additional retaining walls or spreading the walls farther apart would create a greater area of disturbance and could require removing more trees. He stated that the design involved balancing the drainage requirements, parking elevations, and retaining wall configuration. - Mr. Moronski stated that tiering the retaining walls would result in greater disturbance. He further explained that the approximately 21-foot-high portion of the wall extended for only about 13 linear feet out of more than 1,300 linear feet of retaining wall, representing approximately 1% of the total wall length. - Mr. Schkolnick clarified that the retaining wall would have varying heights and that the maximum height of approximately 21 feet would occur along only about 13 feet of wall. - Ms. McGovern asked what the average retaining wall height would be. Mr. Moronski stated that he did not have the average height available at that moment. Mr. Schkolnick acknowledged the question and indicated that the information would be looked into. - Mr. Cote requested permission to provide additional clarification concerning the retaining wall. - Mr. Cote explained that the stormwater basin tapers downward at one end and that the approximately 13-foot section where the wall
n to provide additional clarification concerning the retaining wall. - Mr. Cote explained that the stormwater basin tapers downward at one end and that the approximately 13-foot section where the wall reaches its maximum height is located at the lowest portion of the basin. - Mr. Cote stated that the wall is approximately 6 feet high at the opposite end of the basin and decreases in height as it continues around the corner. He explained that the highest wall section was necessary because of the depressed area required to size the stormwater basin. - Mr. Cote stated that spreading out the grading or using additional tiers would increase the area of disturbance, extend farther into the existing tree line, and require additional tree removal. - Mr. Cote confirmed that alternative alignments and designs had been considered. He stated that the other options would have resulted in greater impacts, additional impervious coverage, and more disturbance to achieve the same result. - Chairman Bagoff asked Mr. Moronski whether the retaining wall would be visible to motorists driving along Eagle Rock Avenue. Mr. Moronski stated that the wall would be set back a considerable distance from the roadway. Mr. Cote also stated that visibility of the wall from Eagle Rock Avenue would be minimal because a tree line would be planted in front of it and the stormwater basin itself would contain landscaping. - Chairman Bagoff asked whether evergreen trees could be planted in front of the retaining wall to provide permanent screening and greater density, so motorists would see greenery rather than the wall. Mr. Cote stated that additional trees might be possible but that the
File revisions (1)
- Nov 4, 2026
e517e0133e50343,414 bytes