Supporting Documentation · May 20, 2025
146-25 Ex. A to Easement Agreement-46 Mount Pleasant Avenue.pdf
2d74d5c4ea8f2060bef103f79675fcda16b56c6ae5710e32afc0e6c9cee9a02dIndexed text · page 1
Show all pagesINSTALL (2) CHARGE POINT EXPRESS 250 LEVEL III CHARGING STATIONS ON CONCRETE PAD (TYP OF 2) INSTALL (2) BOLLARDS 3'-0 ON CENTER PER CHARGER (SEE BOLLARD DETAIL) T ROUTE (1)3" & (1)3 4 PVC-SCH.40" FBELOW GRADE OR SHARED POWER AND COMMUNICATION INSTALL EV CHARGER SIGN (TYP OF 2) ROUTE (1) 2" PVC-SCH.40 BELOW GRADE TO CHARGERS INSTALL (UG) UNDERGROUND ENCLOSURE DRIVEWAY ROUTE 2" PVC-SCH.40 BELOW GRADE TO CHARGER #1 ROUTE 2" PVC-SCH.40 BELOW GRADE TO CHARGER #2 EV PARKING SLOT #1 EV PARKING SLOT #2 EXISTING PARKING SLOT EXISTING PARKING SLOT EXISTING PARKING SLOT EXISTING PARKING SLOT EXISTING PARKING EXISTING PARKING SLOT EXISTING PARKING SLOT WEATHER TIGHT CONDUIT PENETRATION JWP ROUTE FEEDERS TO DISCONNECT SWITCHES THROUGH THE TOP AND BOTTOM WIREWAYS (2) 480 VOLTS 100 AMP CIRCUIT BREAKER TYPE DISCONNECT SWITCH IN NEMA 1 ENCLOSURE (MIN.18 KAIC) PENETRATE 2" CONDUIT THROUGH WALL ROUTE 2" CONDUIT ALONG WALL. (ENTIRE LENGTH FROM TRANSFORMER TO THROUGH SHOULD NOT BE MORE THAN 25'-0) NEW 150.0 KVA STEP DOWN TRANSFORMER PRIM: 480 VOLTS SEC: 120/208 VOLTS ROUTE 4" CONDUIT ON WALL 400 3 CONNECT NEW FEEDER TO EXISTING 400 AMP CIRCUIT BREAKER IN PANEL SECTIONED MAIN DISTRIBUTION PANEL 'MDP-1' EXISTING 120/208 VOLTS 1000 AMPS SWITCHBOARD WITH SECTIONED MAIN DISTRIBUTION PANEL 'MDP-1' M EXISTING GAS PIPING LOCATION OF EXISTING GAS METER AND PIPINGS (ELECTRICAL FEEDS SHALL CIRCUMNAVIGATE AROUND PIPINGS AND OTHERS) UTILITY ROOM PARKING/ DRIVEWAY AREA DRIVEWAY MAGNETIC FOR REVIEW ONLY, NOT FOR CONSTRUCTION 12.20.2024 NOTE: CONTRACTOR MUST REFER TO THE MANUFACTURER FOR FULL ELECTRICAL DETAILS, INSTALLATION MANUAL AND SHALL BE RESPONSIBLE FOR FULL INSTALLATION TO COMPLETE THE SYSTEM. CHARGER SCHEDULE MANUFACTURER MANUFACTURER & EQUIPMENT FEATURES KW VOLTS PHASE AMPS BREAKER CONDUCTOR SIZE & COUNT GROUND SIZE & COUNT CONDUIT SIZE & TYPE CHARGE POINT CHARGE POINT: CPE-250 EXPRESS 250 LEVEL III (1) CCS1 VEHICLE CONNECTOR, (1) CHADEMO VEHICLE CONNECTOR 62.50 480 3Ø 75 100 1 #2/0 2" PVC - SCH.40 EXISTING MAIN DISTRIBUTION PANEL 'MDP-1' 120 / 208 VOLT 3Ø, 4 WIRE CKT LOCATION / ITEM KVA WIRE GND BREAKER BREAKER GND WIRE KVA LOCATION / ITEM CKT 1 EXISTING LOAD (HVAC-2) 250 400 150.0 KVA TRANSFORMER (PRIMARY VOL: 208 VOLTS SECONDARY:480 VOLTS 2 3 #2/0 #400KCML 125.0 4 5 3 3 6 7 EXISTING LOAD ('2A') 125 100 EXISTING LOAD ('1A') 8 9 10 11 3 3 12 13 EXISTING LOAD (ELEVATOR) 100
150.0 KVA TRANSFORMER (PRIMARY VOL: 208 VOLTS SECONDARY:480 VOLTS 2 3 #2/0 #400KCML 125.0 4 5 3 3 6 7 EXISTING LOAD ('2A') 125 100 EXISTING LOAD ('1A') 8 9 10 11 3 3 12 13 EXISTING LOAD (ELEVATOR) 100 70 EXISTING LOAD (KITCHEN) 14 15 16 17 3 3 18 19 EXISTING SPARE 70 70 EXISTING SPARE 20 21 22 23 3 3 24 25 EXISTING SPARE 30 20 EXISTING SPARE 26 27 28 29 3 3 30 31 SPACE 20 EXISTING SPARE 32 33 34 35 3 36 EXISTING PANEL WITH 36 POLES HAS 1000 AMP MLO. ALL HVAC EQUIPMENT AND MOTOR LOADS SHALL HAVE HACR TYPE CIRCUIT BREAKERS EST. EXISTING LOAD: 120.0 KVA NEW LOAD: 125.0 KVA EST. TOTAL LOAD: 245.0 KVA E-1 WALTER W. SPENCER JR. CONSULTING ENGINEERS Drawing No: Bryan Electric Co. Inc. ELECTRICAL SERVICE TO EV CHARGING STATIONS EV CHARGING STATION FOR OLD WEST ORANGE LIBRARY AT 66 MAIN STREET W.ORANGE, NJ 08104 Project Title: 12/23/2024 Date: AS SHOWN Scale: Drawn by: Drawing Title: AA App by: - www. bryanelectricco.com NJ Lic. # 6222 Studio Park 1800 East State St., Suite 150C Hamilton, NJ 08609 609-393-8325 107 Coles Rd. Blackwood, NJ 08012 Phone: (856) 374-0056 Fax: (856) 374-1011 1 E-1 EV CHARGER POWER PLAN SCALE: 1/4" = 1'-0 2 E-1 KEY PLAN NO SCALE AREA OF WORK OLD WEST ORANGE LIBRARY MT. PLEASANT AVE. MAIN ST. EV CHARGER POWER PLAN, EQUIPMENT SCHEDULE & KEY PLAN 3 #2 (MIN.)
File revisions (1)
- Sep 29, 2026
2d74d5c4ea8f1,717,610 bytes