12. CONTRACTOR IS RESPONSIBLE FOR VERIFYING WITH ALL UTILITY BASEMENT & MAIN COMPANIES FOR CUT OFF SERVICES (ELECTRIC, WATER, GAS, FIRE SERVICE, TELEPHONE, ETC.) LEVEL - DEMO PLAN 13. ALL OUTLETS, SWITCHES, WIRING, LIGHT FIXTURES, ETC. IN EXISTING WALLS OR CEILINGS BEING REMOVED SHALL BE DISCONNECTED AND REMOVED BY A LICENSED ELECTRICAL CONTRACTOR. Drawn By: AJG Checked By: FC3 14. THE CONTRACTOR SHALL EXECUTE ALL WORK WITHIN THE REGULATIONS

Page 20

14. THE CONTRACTOR SHALL EXECUTE ALL WORK WITHIN THE REGULATIONS OF THE BUILDING CODE OR ANY OTHER CODE HAVING JURISDICTION FOR DEMOLITION. AD-100 25-003 AD-100 1 1/4" = 1'-0" 25-003 04-06-2025 © F E D C B A

Page 21

ARCHITECT OF RECORD: FC3 ARCHITECTURE+DESIGN, LLC NJ CERT. OF AUTHORIZ. #AC-58100 22'-3" 12" CMU CORE-FILLED WALL SCHEDULE 2x4 STUD WALL W/ FOUNDATION WALL

Page 21

FOUNDATION WALL 1/2" GYP. BOTH SIDES 4'-0" 4'-0" 14'-3" W/ 1-#4 VERT. REBAR EXISTING WALL CONSTRUCTION. TYP. 2x4 WOOD CONSTRUCTION (V.I.F.) SPACKLE, SANDED, 4' O.C. 2' FROM EDGE PAINTED ON A 2' x 1' CONT. NEW INTERIOR 2x4 WOOD STUD PARTITION @ 16" O.C. W/ ONE LAYER 1/2" 36x18 SLIDER CONC. FOOTING GYP. BD. EACH SIDE. USE WATER RESISTANT GYP. BD. AT ALL WET AREAS

Page 21

GYP. BD. EACH SIDE. USE WATER RESISTANT GYP. BD. AT ALL WET AREAS (MIN. 3500 PSI) W/ USE CEMENTITIOUS BACKER BD. AT ALL SHOWERS / TUBS. 2-#4 REBAR HORIZ. GFI GFI REFER TO SECTION NO. 3 THIS PAGE NEW EXTERIOR WALL CONSTRUCTION: 8" CMU, CORE-FILLED BASEMENT WALL GFI

Page 21

GFI 2x10 FLOOR JOISTS 2x10 FLOOR JOISTS FRANK CUNHA III, AIA, NCARB @ 16" O.C. O.C.

Page 21

REGISTERED ARCHITECT CRAWL SPACE STORAGE NEW JERSEY #16411 @ 16" GFI 9'-0" CONC. NEW ADDITION 3

Page 21

NEW ADDITION 3 FC3 PROJECT NO. 26-NJ-XXX W8x12 W/ 2 A-100 HSS 4x4x1/4 HSS 4x4x1/4 COLUMN / POST NOTE: GENERAL FOUNDATION NOTES: 6 ON 1'x1'x1' FOOTING 32x80 1. ALL EXTERIOR DIMENSIONS MEASURED TO OUTSIDE FACE OF CMU WALL,

Page 21

1. ALL EXTERIOR DIMENSIONS MEASURED TO OUTSIDE FACE OF CMU WALL, 1. POSTS FOR "ONCENTER" STEEL BEAM TO BE SOLID THRU TO REST ON SOLID CONCRETE FOUNDATION, STL. COLUMN OR POST BELOW. ALL INTERIOR DIMENSIONS MEASURED TO INTERIOR FACE OF CMU, ALL EXIST. GARAGE INSTALLED IN ACCORDANCE W/ MANUFACTURERS SPECIFICATION. VERTICAL DIMENSIONS ARE TAKEN TO TOP OF GROUND.

Page 21

2. ALL DIMENSIONS TO BE VERIFIED IN FIELD. 2'-4" 10'-0" 2'-4" 3. FINAL STRUCTURAL DESIGN TO BE REVIEWED AND APPROVED BY LICENSED NEW EX. FAN 14'-7 1/2" STRUCTURAL ENGINEER. VENT THRU STORAGE